TECHNICAL GUIDE - Georgia-Pacific Building Products
Dec 01, 2017 · FM or RoofNav®, FM’s tool for roofing professionals. Please note, however, that the performance of a roof depends on all components used in the roofing assembly and how the components interact. ASTM C1177. 5/8” (15.9 mm) DensDeck and 5/8” (15.9 mm) DensDeck Prime Roof Boards are manufactured to meet the “Type X”
Tags:
Guide, Performance, Product, Pacific, Building, Georgia, Roofing, Georgia pacific building products
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Technical Guide: DensArmor Plus® High-Performance Interior ...
www.buildgp.comof Gypsum Panel Products” and ASTM C840 “Standard Specifi cation for Application and Finishing of Gypsum Board for Non-Fire Rated Construction.” For best results, abut DensArmor Plus panels against regular paper-faced drywall only at inside or outside
TECHNICAL GUIDE - Georgia-Pacific Building Products
www.buildgp.cominstallation. DensGlass Sheathing is the ideal substrate for a wide variety of air and water-resistive barriers including building wraps, fluid applied coatings, self-adhering membranes and spray foam applications. See page 10 for details. Easy to Handle DensGlass Sheathing is lightweight and easy to handle.
Guide, Product, Technical, Pacific, Building, Georgia, Wrap, Technical guide, Building wraps, Georgia pacific building products
SHAFTLINER FOR SHAFTWALL/STAIRWELL SYSTEMS
www.buildgp.comNote that the edges of the panel are beveled to help guide the panel into the slotted and tabbed section of the stud. 6. Progressively install succeeding studs and panels as described above until the wall section is enclosed. The final panel section may be secured with 1-5/8” (41 mm) Type S screws or tabs from the J track at 24” (610 mm) o ...
Technical Service Hotline 1.800.225.6119 or www.gpgypsum
www.buildgp.comassembly installation instructions). Primary Uses Because of the superior performance of DensGlass Sheathing, it is specified for exterior walls, ceilings and soffits in a wide variety of applications. These include exterior insulation and finish systems (EIFS); cavity brick or stone veneer applications;
Services, Installation, Technical, Instructions, Installation instructions, 1961, Hotline, Technical service hotline 1, 6119 or
Densglass Shaftliner Area Walls Technical Guide
www.buildgp.comBuilding Code (IBC) Section 706, “Fire Walls.” The Area Separation Wall assembly using DensGlass Shaftliner panels is listed in the UL Fire Resistance Directory under UL Design U373 or U375, the ULC Fire Resistance Directory ULC Design No. W312 and the
Stamps/Signatures
www.buildgp.comFIRE SAFETY CAUTION Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain …
DensShield® Tile Backer Installation Instructions
www.buildgp.comDS001. Note: Shower pan or rubber membrane must be adequately sloped to the open drain or weep hole detail to permit proper water drainage. Leave a 1⁄89 (3 mm) gap between DensShield Tile Backer and the shower pan. • DensShield Tile Backer is not to be used in shower curbs. • DensShield Tile Backer panels can be installed in the shower
Technical Service Hotline 1.800.225.6119 or www.densdeck
www.buildgp.commanufacturer’s specifications for full mopping applications and temperature requirements. ... * Testing was done in accordance with FM approvals 4470, Appendix C: Small Scale Tests, Membrane ... with the ANSI/UL 1256 Steiner Tunnel test. For additional information concerning
Tests, Scale, Tunnel, Full, Cast steel
Related documents
The Florida Building Code
www.floridabuilding.org• Roofing & Sheet Metal Contractor. ... • Performance » ASCE 7-98. ... » WPPC Guide to Wood Construction in high wind areas. Chapter 16 - Structural Loads Design Methods: • Metal Flag Poles » Designs using NAAMM FP-1001 specification for design loads of metal flag poles.
Guide, Performance, Code, Building, Florida, Metal, Florida building code, Roofing
FLASHING GUIDE - Lysaght
professionals.lysaght.com2.6 Maximum lengths of roofing 6 2.7 Low roof pitches 6 2.8 Wind forces on roofs 6 2.9 Codes and performance tests 6 2.10 Specifications - roofing profiles 7 2.11 Specifications - walling profiles 8 3.0 ®Roof flashings 9 3.1 Design 9 3.2 Roof …
ROOFING & WALLING INSTALLATION MANUAL - Lysaght
www.lysaght.com2.4 Maximum lengths of roofing 6 2.5 Low roof pitches 7 2.6 Wind forces on roofs 7 2.7 Codes and performance tests 7 2.8 Environmental conditions 7 2.9 Metal and timber compatibility 7 2.10 Transportation 8 2.11 Paint and COLORBOND® finishes 8 2.12 Specifications - roofing 9 2.13 Specifications - walling 10
Modified Bitumen Roofing Membranes - Johns Manville
www.jm.comSPECIFICATIONS The Dibiten Specifications Manual has been prepared to serve as a guide for architects, specifiers, roofing con-tractors and others involved in the roof system selection and application process. This manual is intended only as a guide and the recommendations represent Dibiten’s best judgement based on years of experience in the
Architectural Metal Roofing and Siding COLOR CHART
www.aepspan.comVintage coated metal is an innovative coating process over a TruZinc® G90 metallic coated steel surface producing a beautiful, durable, aged-metallic finish. COLOR CHART 800-733-4955 Custom colors available by request www.aepspan.com Architectural Metal Roofing and Siding STANDARD COLORS DURA TECH™ 5000 - Premium 70% Fluoropolymer (PVDF) Coating
REPAIR AND RE-COVER ROOFING GUIDE - Soprema
www.soprema.caO SOPREMA 3 REPAIR AND RE-COVER ROOFING GUIDE Table of Contents 1.0 EVALUATION OF THE CONDITION OF THE ROOFING SYSTEM 4 1.1 Visual inspection 4 1.2 Thermographic or hygrometric analysis 5 1.3 Types of defects 5 2.0 RECONSTRUCTION OF SBS MODIFIED BITUMEN MEMBRANES 6 2.1 Granule loss 6 2.1.1 Membrane regranulation …
Guide, Cover, Repair, Roofing, Repair and re cover roofing guide
6th EDITION Florida High Wind Concrete and Clay Tile ...
tileroofing.orgEave Closure – Metal, concrete, clay, mortar and raised fascia are all approved. Flexible Flashing Products – Conforming to ICC-ES AC-148 and conform to ASTM D4434, D4637 or D5019. Hip and Ridge Metal – Shall be in compliance with the FBC. Hip and Ridge Metal shall meet the test re-quirements of SSTD 11-99 and verified by third-party
High, Florida, Metal, Concrete, Wind, Florida high wind concrete and
Roof Insulations - Johns Manville
www.jm.cominsulations and cover for single ply, built-up, metal and modified bitumen roofs. The section that follows reviews the storage, installation and use instructions for the cover board and insulation board product lines. JM product line. Prior to product …