Example: biology

Technical Magnetic Flowmeter Information ADMAG …

Technical Magnetic Flowmeter Information ADMAG AXF. TI 01E20A01-20E. Contents 1. Introduction .. 3. 2. Application .. 4. 3. ADMAG AXF Series Lineup .. 5. 4. Product Concept .. 6. 5. User-oriented Functionality .. 7. LCD Indicator .. 7. Compact and Light-weight Design .. 10. Flexible Electrical Connection Direction .. 11. 6. High Quality/High Performance .. 12. Fluid Adhesion Level Diagnosis .. 12. Replaceable Electrode .. 13. Enhanced Dual Frequency Excitation .. 14. 7. Wide Product Lineup .. 16. Extra Small Size Flange .. 16. Sanitary type .. 17. Size, Lining and Materials .. 18. Face-to-face Length .. 20. Explosion Proof Type Remote Converter AXFA14 .. 21. Versatile Input/Output Function .. 22. Yokogawa Electric Corporation TI 01E20A01-20E. 2-9-32 Nakacho, Musashino-shi, Tokyo 180, Japan Copyright Nov. 2005. Tel.: 81-422-52-4443 Fax.: 81-422-52-2018 2nd Edition Feb. 2016. <Toc> <Ind> 3. 1. Introduction Yokogawa developed the first industrial Magnetic Flowmeter in Japan in 1955, and in 1988, the world's first dual frequency excitation method: ADMAG series was released.

7.3.2 Wetted Part Material T070302.eps, A

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Technical Magnetic Flowmeter Information ADMAG …

1 Technical Magnetic Flowmeter Information ADMAG AXF. TI 01E20A01-20E. Contents 1. Introduction .. 3. 2. Application .. 4. 3. ADMAG AXF Series Lineup .. 5. 4. Product Concept .. 6. 5. User-oriented Functionality .. 7. LCD Indicator .. 7. Compact and Light-weight Design .. 10. Flexible Electrical Connection Direction .. 11. 6. High Quality/High Performance .. 12. Fluid Adhesion Level Diagnosis .. 12. Replaceable Electrode .. 13. Enhanced Dual Frequency Excitation .. 14. 7. Wide Product Lineup .. 16. Extra Small Size Flange .. 16. Sanitary type .. 17. Size, Lining and Materials .. 18. Face-to-face Length .. 20. Explosion Proof Type Remote Converter AXFA14 .. 21. Versatile Input/Output Function .. 22. Yokogawa Electric Corporation TI 01E20A01-20E. 2-9-32 Nakacho, Musashino-shi, Tokyo 180, Japan Copyright Nov. 2005. Tel.: 81-422-52-4443 Fax.: 81-422-52-2018 2nd Edition Feb. 2016. <Toc> <Ind> 3. 1. Introduction Yokogawa developed the first industrial Magnetic Flowmeter in Japan in 1955, and in 1988, the world's first dual frequency excitation method: ADMAG series was released.

2 Afterwards, we have developed ADMAG AE which has the lineup of the flameproof construction of the integral type, and ADMAG CA of capacitance type which has no wetted electrode. Thus we have been leading the technology of this field and sold 600,000 or more units. And now, true user-oriented functionality was achieved succeeding to high performance and the high quality as a successor of these series, the function was developed more greatly, and enhanc- ing was developed. ADMAG AXF series is a product that has the best ability in the world to enhance the function of the conventional model. When developing, we heard the demand from the various customers, and most of the demands were achieved. Pulp & Paper Food & Beverage More Enhanced Applications for ADMAG AXF. Dressing Sauce Blow Line DIP Pulp Starch Gelatin Beer Dye Beverage Retort Food White Liquor Dessert including Fruit Black Liquor Flesh Utility Latex Hydrochloric acid Blast Furnace Tuyere Sulfuric acid Cooling Water Sodium hydroxide Various type of Resin Continuous Cast Cooling Water Chemical Iron & Steel Application for the general Magnetic Flowmeter This figure is an application chart of each industry.

3 Using ADMAG AXF series provides the customer the flow measurement of wider application. In this TI ( Technical Information ), we introduce the example of the application and the functionality of ADMAG AXF series etc. Please read through this TI and select the ADMAG AXF series for your flow measurement. Please confirm details of the specification with General Specification sheet. It can be found in the following URL. All Rights Reserved. Copyright 2005, Yokogawa Electric Corporation TI 01E20A01-20E <Toc> <Ind> 4. 2. Applications Following table shows the example of application for ADMAG AXF. Feature of AXF. Standard Specification Special Order Spacification Change of Surface Finishing (Lining/Electrode). Flame Proof (AXFA14, AXF Integral, Remote). Abrasion Resistant Urethane Rubber Lining /DHC :For District Heating and Cooling or Enhanced dual frequency Excitation Internal Insertion Type Electrode Application Fluid Adhesion Level Diagnosis Various Sanitary Connections Industry /ELC :FDC Noise Cut Circuit Change of Electrode Shape Fluid Natural Soft Rubber Lining Low Conductivity(1 S/cm).

4 Extra Small Flange Type Replaceable Electrode EPDM Rubber Lining JIS 63K Wafer Meter Metal Hat Earth Ring 10 KHz Pulse output Condensation-proof . Iron & Steel Food & Beverage Bottling Machine Beverage Pure Water, Vinegar, Alcohol, Low Conductivity Fluid Liquid Suger, Carbohydrate . Solution Mayonnaise, Dressing, Sauce, Oily Adhesive Fluid . Baste Retort Food, Desser including Solid included Liquid . Fruit Flesh, Sherbet Blast Furnace Tuyere Coolant Water . Cooling Water Continuous Cast Coolant Water . Cooling Water Latex, Various types of Resin, Adhesive Fluid . Chemical Sodium Hydroxide Electrolysis Plant Electrolysis Solution . Pure Water, Alcohol, Acetic Acid, Low Conductivity Fluid . Organic Solvent PVC Piping Strong Acid, Strong Alkali . Digester Black Liquor . DIP Pulp . Pulp & Paper Adhesive Liquid such as Chlorine, Bleaching . Alkali, HYPO. Pulping Size agent, Aluminum Sulfate . Concentrated Black Liquor, Recovery Boiler Line.

5 Green liquor PVC Piping Additive, .. Environment Construction Shielding Machine Excavated Mud Slurry Shield Excavated Mud . Mortar Mortar . Grout Cement Milk, Sodium Silicate . Water & Waste process Water . District Heating and Coolant . Cooling Sodium Hydroxide, Hydrochloric PVC Piping . Acid, Hypochlorous Acid : Proven Application In case of the high slurry, low conductivity or adhesive fluid, please consider to apply ADMAG CA. All Rights Reserved. Copyright 2005, Yokogawa Electric Corporation TI 01E20A01-20E <Toc> <Ind> 5. 3. ADMAG AXF Series Lineup Integral and Remote types are available Integral Type Magnetic Flowmeter Model AXF G : General-Purpose Use W: Submersible Type C : Explosion proof type H : Sanitary Type Model AXF G : Genaral-Purpose Use W: Submersible Type C : Explosion proof type Remote Type Magnetic Flowmeter H : Sanitary Type Model AXFA14G : Genaral-Purpose Use AXFA14C : Explosion proof type Remote Converter Remote Flowtube Remote High Spec.

6 Converter Remote High Spec. Converter Model: AXFA11G (General-Purpose Use). All Rights Reserved. Copyright 2005, Yokogawa Electric Corporation TI 01E20A01-20E <Toc> <Ind> 6. 4. Product Concept Concept of 3 Key Points of AXF. The 1st Key Point I Pursuit of User Friendly User-oriented Functionality Backlit Full Dot-matrix LCD( ). Enrichment of Alarm Messages Multilingual Easy Setup Infra-red switch( ). Flexible Electrical Connection Direction( ). Compact and Light-Weight( ). Replaceable Electrode( ) Replacement Lay Length( ). Extra Small Size Flange Type( ). Fluid Adhesion Level Diagnosis ( ) Various Sanitary Connections Enhanced Dual Frequency ( ). Excitation( ) EPDM/Natural Soft Rubber Lining( ). High Performance Noise Immunity Explosion Proof Type Converter( ). The 2nd Key Point The 3rd Key Point II Super Magmeter III You can find what you want High Quality/High Performance Wide Product Lineup Please refer to the page number in each items parenthesis.

7 All Rights Reserved. Copyright 2005, Yokogawa Electric Corporation TI 01E20A01-20E <Toc> <Ind> 7. 5. User-oriented Functionality LCD Indicator Display of Flow Rate etc. and Setting of the parameters are possible. Not only Alarm message but also Countermeasure is displayed at the same time. Infra-red switch enables easy setting without opening the cover. LCD Indicator Display Items are selectable up 32 132 Full Dot-matrix LCD with to 3 lines. backlit enables various indication. Alarm Display (refer to page 8). Operating feeling is as same as the mechanical switch. Response region is near the glass to avoid the wrong operation. Response Region Setting Switch Easy setting by Infra-red Switch Glass without opening the cover. Emission Receiver Element Element Infra-red Switch Flow Rate display and Parameter setting [Example]. 1 Line (Flow Rate). Select Item (Parameter Number). 2nd Line (H12). 1st Line (H10). 3rd Line(H13). Flow Rate(%) (No indication).

8 Flow Rate Flow Rate(%). Flow Rate(mA) Flow Rate 2 Lines (Flow Rate and Flow Total) Forward Total Flow Rate(mA). Reverse Total Flow Rate(Bar). Dif Total Forward Total Reverse Total Dif Total Tag No Adhesion Check Communication 3 Lines (Flow Rate, Flow Total and Bar graph). Multi-line display up to 3 lines is possible. All Rights Reserved. Copyright 2005, Yokogawa Electric Corporation TI 01E20A01-20E <Toc> <Ind> 8. Alarm Display Alarm messages are displayed in multilingual Normal Display and Alarm Display are displayed alternately when alarm is generated. Normal Display Mode 2 seconds Alternate Alarm Display Mode 2 seconds English German French Italian Spanish Japanese Countermeasures are also displayed for the easy maintenance. Multilingual: English, German, French, Italian, Spanish and Japanese. All Rights Reserved. Copyright 2005, Yokogawa Electric Corporation TI 01E20A01-20E <Toc> <Ind> 9. Parameter Setting Multi-line Display Easy Set without opening the cover Setting is easy by only 3 keys.

9 SET SHIFT . Touch on the cover. Infra-red Switch Write Protect Function is equipped and Setting parameters are protected. Security is improved. EASY SETUP. The most frequently used 14 parameters among 95 parameters are arranged in a group at the top. General functions can be set by these parameters. Multilingual supports English, German, French, Italian, Spanish and Japanese. B:Easy Setup B:Schnell Einstieg B10:Language B10: Sprache B20:Flow Danping B20:Flow Dampfung English German B21:Base Flow Unit B21:Flow Einheit B22:Base Time Unit B22:Basis Zeiteinheit B23:Flow Span B23:Flow Spanne B24:Flow Decimal Pnt B24:Flow Dezimalpunkt B30:Total Unit B30:Zahler Einheit B31:Total Scale B31:Zahler Skalierung B32:Pulse Unit B32:Puls Einheit B33:Pulse Scale B33:Puls Skalierung B40:Display Select1 B40:Zeile 1 Auswahl B41:Display Select2 B41:Zeile 2 Auswahl B42:Display Select3 B42:Zeile 3 Auswahl B50:Auto Zero Exe B50:Auto Zero Ausf. C:Basic Setup C:Basis Einstellung D:Total Set D:Zahler Setzen E:Pulse Set E:Puls Setzen F:Status Function F:Status Funktion G:Alarm G:Alarm H:Display Set H:Anzeige Konfi.

10 J:Aux J:Hilfsmen K:Diagnosis K:Diagnose M:Adjustment M:Justierung N:Test N:Test P:Protect P:Schutz All Rights Reserved. Copyright 2005, Yokogawa Electric Corporation TI 01E20A01-20E <Toc> <Ind> 10. Compact and Light-weight Design Shorter lay-length, Smaller case and Lighter weight. AXF050. AE205 (earlier model). Wide and Clear LCD. AE205 AXF050 (In case of 50mm wafer). (approx. 30% decrease). The infra-red switch is adapted. The operability is the same as a mechanical swith. Shorter Lay Length contributes to the new plant. Replacement Model is also available (refer to page 20). AM11 (earlier model) AXFA11. Dimension of the Vertical direction is shortened to 2/3. AM11 AXFA11. (approx. 40% decrease). Dimension of the horizontal direction and the terminal pitches are the almost same as the earlier model to keep the space for easy wiring. ADMAG AXF won iF design award 2005 (International Forum Design Awards). The iF awards for outstanding design quality are one of the most prestigious recognitions given to international manufactures and designers by the Interna- tional Forum Design in Hannover (Germany).