Transcription of Temperature Sensor Install Guide - IntelliCenter EasyTouch ...
1 IMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIONSSAVE THESE INSTRUCTIONSINSTALLATION GUIDETEMPERATURE Sensor KITFOR USE WITH IntelliCenter , EasyTouch , INTELLITOUCH , SUNTOUCH AND COMPOOL TO EasyTouch UPGRADE CONTROL SYSTEMS Temperature Sensor installation instructions Temperature Sensor installation Instructions2 Technical Support (800) 831-7133 am to pm ET am to pm PTKit contentsThe following items are included in the water/air Temperature Sensor replacement kit: Temperature Sensor Assembly - P/N 520872 Temperature Sensor , 10k Temperature Sensor - P/N 520326 Temperature Sensor , 10k Ohms, 40 ft - P/N 521583 Temperature Sensor , 10k Ohms, 20 ft - P/N 521584 Hose Clamp (1-7/8 - 5 Clamp) - P/N 476168 installation instructions (this manual)Water/Air Temperature SensorThe Sensor can be used as a water or air Sensor .
2 The 10k Ohms Temperature Sensor can be is used with IntelliCenter , IntelliTouch, EasyTouch , SunTouch and Compool to EasyTouch Upgrade Control Systems. Related manuals IntelliCenter Control System User s Guide (P/N 522990)IntelliTouch Control System User s Guide (P/N 521075) EasyTouch Control System User s Guide (P/N 521044)SunTouch Control System User s Guide (P/N 520785)P/N 520326 5/2019 Temperature Sensor installation Instructions3 Note: See page 4 and 5 for circuit board Sensor connector The existing water Sensor is located between the filter pump and the filter. Remove the Sensor . 2. Drill a 3/8th inch hole in the 3-in or 2-in pipe. Position the hose clamp over the replacement Sensor and gently tighten around pipe.
3 Caution: Do not overtighten clamp. 3. Route the cable up through the low voltage compartment of the Load Center or Power Center to the Outdoor Control Panel circuit board. 4. Strip wires back 1/4 inch. Connect the Sensor wires to WATER screw terminals. See page 4 and 5 for screw terminal Air Temperature (Freeze Protection) Sensor Replacement Mount Sensor in open air, in shaded area, away from air conditioners. Route the cable up through the low voltage compartment of the Load Center or Power Center to the Outdoor Control Panel circuit board. Use cable ties to fasten Sensor cable to pipes. Strip wires back 1/4 inch. Connect the Sensor wires to AIR screw terminals. See page 4 and 5 for screw terminal replacing the existing water Temperature Sensor , be sure to use drill a 3/8th inch hole into the 3-in or 2-in pipe for the new Sensor .
4 Note: The existing water Sensor hole is 5/16th inch, and will not fit the new replacement Sensor . IMPORTANT NOTE: Replacing the existing Water Temperature "DrillPipeClamp2-in or3-in PipeSensor InstallationTemperature Sensor installation instructions Temperature Sensor installation Instructions4 IntelliTouch Control System Circuit BoardEasyTouch Control System Circuit BoardIntelliCenter Control System Circuit Board(Air, Water and Solar Sensor location)AIRSOLARWATERAIRSOLARWATER(J15) IntelliCenter Control System Circuit Board Temperature Sensor installation Instructions5 SunTouch Control System Circuit BoardVALVE ACTUATORSINTAKERETURNSOLAR AUX 3 PUMPAUX 2 AUX 1 VLV AVLV BVLV CONLYSOLARCLNR GASHEATERRESETCR2032+3VJ12AJ910K OHM THERMISTOR SENSORS(Red/Blk wires are interchangeable)
5 To EasyTouch Indoor Control Panelor iS10 Spa-Side Remote (for CP3800 series)to CONTROL PANELor iS10 COMPOOL TO EasyTouch WIRING DIAGRAMSENSORSAIRSOLARTRANSFORMERCONNECT IONS18 VAC10 VAC24 VACREDBLURED/WHORGORG/WHBLU/WHPCB Assy #521099 MODTELSPAEXT CTRL2-SPDSOLAREHTRAUX7 AUX6 AUX5 AUX4 AUX3 AUX2 AUX1 PUMPSPAVL V BVLV ARETURNINTAKECOM PORTBLKGRNYELREDHEATERREDBLKAIR SENSORWATER SENSORREDBLKREDBLKSOLAR SENSORJ19J24J23J2J3J4J5J7J8J9J10J11J6J25 [See Important Note]J12J13J14J15J16J17J18J21J22 AUXILIARY RELAYS (1-7)POOL HEATERCONTROLGAS VALVEPRESSURETHERMOSTATLIMITOFFONWATERIS 4 REMOTE3G4 BORGBLK2Y1RJ20 TRANSFORMERFACTORY WIRINGOUTPUT: 10 VAC 18 VAC 24 VACLOW VOLTAGE CIRCUIT BREAKERSBLKORGREDYELGRNBLUCOM PORTRJ12 AdapterEasyTouch Indoor Control Panelor iS10 for CP3800 series REDGRNYELBLKYELREDGRNBLK10V18V24 VTO GAS HEATER TERMINALS FORREMOTE CONTROL OPERATION, ORTO FIREMAN'S SWITCH :DO NOT BYPASS INTERNAL HEATERTHERMOSTAT, HIGH LIMIT SWITCH,OR OTHER SAFETY PORT: EasyTouch Indoor Control Panel,RF Transceiver, iS4, iS10 Spa side Remote,IntelliFlo VF IntelliFlo VS, QuickTouch and CP/ET RJ12 Adapter for Indoor Control NOTE.
6 J25 Jumper is Factoryset on both Single Body Systems,the Jumper only needs tobe attached on 1 Shared EquipmentSystems, the Jumperneeds to be attachedon both VALVE Aor SOLARACTUATORAUX VALVE BACTUATORand/orBLUBLUC ompool EasyTouch Upgrade Control System Circuit BoardTemperature Sensor installation instructions Temperature Sensor installation Instructions6 Notes Temperature Sensor installation Instructions7 NotesTemperature Sensor installation instructions Temperature Sensor installation Instructions8 221620 HAWKINS AVE., SANFORD, NC 27330 (919) 566-8000 10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 (805) 553-5000 pentair trademarks and logos are owned by pentair . IntelliCenter , EasyTouch , IntelliTouch , SunTouch , Compool are trademarks and/or registered trademarks of pentair Water Pool and Spa, Inc.
7 And/or its affiliated companies in the United States and/ or other countries. Because we are continuously improving our products and services, pentair reserves the right to change specifications without prior notice. pentair is an equal opportunity employer. 2019 pentair Water Pool and Spa, Inc. This document is subject to change without notice. P/N 520326 5/2019*520326*