Transcription of Type 1010 Pressure Gauge Available With PLUS! …
1 The Ashcroft Type 1010 Gauge is themost economical of the general serviceindustrial gauges having 1% accuracy. The 1010 also is the only Ashcroft gaugeavailable in sizes up to 12 in psi kg/cm2 bar kPa 0/15 0/30 0/60 0/100 0/160 0/200 0/300 0/400 0/600 0/800 0/1000 0/1500 0/2000 0/3000 0/4000 0/5000 0/6000 0/7500 0/10,000 0/20.
2 000 Compound 30 in. Hg/15 psi 1/0 100/0/150 30 in. Hg/30 psi 1/0/3 100/0/300 30 in. Hg/60 psi 1/0/5 100/0/500 30 in. Hg/100 psi 1/0/9 100/0/900 30 in. Hg/150 psi 1/0/15 100/0/1500 30 in. Hg/300 psi 1/0/24 100/0/2400 STANDARD RANGE TABLE*Vacuum 30 1/0 100/0*Full standard and metric equivalent range table Available on our web 41 2, 6, 81 2 and 12 dial sizes Black epoxy- painted aluminum caseOPTIONAL FEATURESO verload Stop XOSU nderload Stop XVST hrottle Plug (.031) Thread-in XTSV isit for the complete features list PRODUCT SPECIFICATIONSM odel Number: 1010 Accuracy: 1% full scale (Grade 1A, ASME )Ranges: Vac.
3 , compound to 30,000 psiDial Size: 41 2 , 6 , 81 2 or 12 diameter Case Material: Black epoxy coated aluminumWeather Protection: Dry Case: IP54 Ring: 41 2 , 6 threaded reinforced black ring 81 2 hinged ring, black epoxy coated 12 slip-fit steel ring, black epoxy paintedWindow: GlassDial: Aluminum, white background, black figures and : Micrometer Adjustable (Friction fit 12 Size)Movement: Rotary, 400 SS, Teflon coatedpinion gear and segmentBourdon Tube Phos. bronze/brass brazed (A)and Socket: 316L SS/316L SS (S) K Monel/ Monel (P)Connection Size: 1 4 , 1 2 NPTC onnection Location: Lower or backMounting: Stem, surface or flushType 1010 Pressure GaugeAvailable with PLUS!
4 Performance OptionAshcroft Inc., 250 East Main Street, Stratford, CT 06614 USATel: 203-378-8281 Fax: 203-385-0408email: specifications are subject to change without notice. All sales subject to standard terms and conditions. 2013 Ashcroft Inc. 08/14 BULLETIN GS-1 10100/1 0/100 0 0/1600 0/2500/4 0/4000/6 0/6000/10 0/10000/16 0/16000/25 0/25000/40 0/40000/60 0/60000/100 0/10,0000/160 0/16,0000/250 0/25,0000/400 0/40,0000/600 0/60,0000/1000 0/100,000 HOW TO ORDER: 45 1010 A 02L XXX 2000#1.
5 Dial size 41 2 , 6 , 81 2 or 12 2. Case type 10103. Tube and socket material4. Connection size 1 4(02), 1 2(04) 5. Connection location Lower (L), Back (B)6. Optional features see above7. Standard Pressure range 2000 psi41 2 CASE SHOWNNote: Other than discoloration of the dial and hardening of thegasketing that may occur as ambient or process temperaturesexceeds 150 F, non-liquid-filled gauges with standard glass windows, can withstand continuous operating temperatures upto 250 F (121 C). Accuracy at temperatures above or below thereference ambient temperature of 68 F (20 C) will be affected byapproximately .4% per 25 F (4 C). Gauges with welded jointswill withstand 750 F (450 F (232 C) with silver brazed joints) for short times without rupture, although other parts of thegauge will be destroyed and calibration will be lost. For continuous use and for process or ambient temperaturesabove 250 F (121 C), a diaphragm seal or capillary or siphon is LIMITS Ambient Process Storage Dry 20/200 F 20/250 F 40/250 F ( 29/93 C) ( 29/121 C) ( 40/121 C)AIGDBCSBIFMHole inpanelNuts & washersnot supplied byAshcroftHLL81 2 Back and Lower Connect41 2 and 6 Back and Lower Connect 41 2 513 16 313 16 47 8 15 8 53 8 11 2 315 16 7 8 5 8 11 16 25 8 21 2 (148) (86) (124) (41) (137) (42) (100) (20) (16) (27) (67) kg 6 79 16 31 2 65 8 15 8 7 11 2 41 2 7 8 5 8 7 16 25 8 31 8 (192) (89)
6 (162) (41) (178) (42) (114) (20) (16) (11) (67) kg 81 2 101 16 27 8 43 4 111 16 95 8 15 8 6 13 8 5 8 11 16 41 2 (256) (73) (121) (39) (244) (41) (152) (35) (16) (17) kg 12 141 2 215 16 141 4 11 32 131 2 21 8 71 2 113 32 5 8 8 (368) (75) (361) (26) (343) (54) (191) (36) (16) kgHCBIF1/4 NPT or1/2 NPTA3-L dia. holeson E dia. Back and Lower ConnectType 1010 Pressure GaugeAvailable with PLUS! Performance OptionDIMENSIONSHTAGTCVBJDF3-L dia. holes on E dia. B. C. IIBULLETIN GS-1 1010 Dial Size A B C D E F G H I J S V WgtInches (lbs)All Ashcroft dials have various total gradua-tion marks, figure intervals and minor gradua-tions.
7 Standard dual scale metric ranges have adominant metric inner scale. The outer scale isspecified in psi. Some examples are gauges are made in accordancewith ASME entitled, Gauges, Pressure ,Indicating Dial Type Elastic Element, Accuracy grade 2A ( of span). The accu-racy of a retard range Gauge applies only to theexpanded portion of the scale. The error in thecompressed portion is 10% to +20% of thespan. Maximum Pressure at which a Gauge iscontinually operated should not exceed 75% offull scale range. Consult customer service inStratford, CT for non-standard GraduationsFigure IntervalsTotal GraduationGraduations and figure intervals Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USATel: 203-378-8281 Fax: 203-385-0408email: specifications are subject to change without notice. All sales subject to standard terms and conditions. 2013 Ashcroft Inc.
8 08/14