Example: biology

Vickers Amplifier Cards Power Plugs for …

For use with valve types:KDG4V-3(S)-H*-6*KTG4V-3(S)-H*-6*KD G4V-5-H*-3*KTG4V-5-H*-3*KCG-3/6/8-H1-1*K X(C)G-6/8-H1-1*KDG5V-5/7/8-H1-1*CMX**-E- GEPV**-12D-1*ERV1/2**-12D-1*EPFR1**-12D- 1*General DescriptionThree types of Plugs , conforming to ISO 4400/DIN 43650 interface, withintegral amplifiers and necessaryadjustment potentiometers, aredesigned for use with non-feedbackhydraulic plug/valve combination offers verylow cost solutions to many hydrauliccontrol problems requiring D is controlled with a 0-10 Vcommand signal, and has adjustablegain, ramp, deadband compensationand J, designed for closed-loopapplications, is controlled with a 0-10 Vcommand signal, and has no K is controlled with a 4-20 mAcommand signal, and has an adjustableramp time of 50 ms to and BenefitsFIntegral Amplifier provides essentialfunctions for control of proportionalvalvesFAdjustable ramp time (types D and K)

Installation Data 4 3 2 1 LED Dither Gain Deadband Ramp Adjustments Ramp time: Turn clockwise to increase ramp time. (Only types D/K) Gain: Turn clockwise to increase gain.

Tags:

  Installation, Power, Plugs, Power plugs for

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Vickers Amplifier Cards Power Plugs for …

1 For use with valve types:KDG4V-3(S)-H*-6*KTG4V-3(S)-H*-6*KD G4V-5-H*-3*KTG4V-5-H*-3*KCG-3/6/8-H1-1*K X(C)G-6/8-H1-1*KDG5V-5/7/8-H1-1*CMX**-E- GEPV**-12D-1*ERV1/2**-12D-1*EPFR1**-12D- 1*General DescriptionThree types of Plugs , conforming to ISO 4400/DIN 43650 interface, withintegral amplifiers and necessaryadjustment potentiometers, aredesigned for use with non-feedbackhydraulic plug/valve combination offers verylow cost solutions to many hydrauliccontrol problems requiring D is controlled with a 0-10 Vcommand signal, and has adjustablegain, ramp, deadband compensationand J, designed for closed-loopapplications, is controlled with a 0-10 Vcommand signal, and has no K is controlled with a 4-20 mAcommand signal, and has an adjustableramp time of 50 ms to and BenefitsFIntegral Amplifier provides essentialfunctions for control of proportionalvalvesFAdjustable ramp time (types D and K)

2 ,gain, deadband compensation andditherFEase of installation , with reduced costFFully short-circuit and reverse-polarityprotectedFDifferential voltage command signal(types D and J)FAdjustable ditherFEMC to latest European standardsFProtection to IP67 ApplicationPrimary applications are in the control ofdirectly operated, non-feedbackproportional valves where the cost ofmore sophisticated electronic controlscan be J is for closed-loop ; 2* Series*1 Electrical Block DiagramEHH-AMP-702-D/J/K-2*2*-EHH-AMP-70 2-Adjustment rangeD = Proportional plug: 50 ms to 5sJ= Proportional plug without rampfunctionK = Proportional plug: 4-20 mAModel Code1 JType J does not have the ramp number, 20 seriesSubject to change. Installationdimensions unaltered for designnumbers 20 to 29 DCPower + + J2 August 1996GB-2115 EThis product has been designed and tested to meet specific standards outlined in the European Electromagnetic CompatibilityDirective (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5.

3 For instructions on installationrequirements to achieve effective protection levels, see this leaflet and the installation Wiring Practices for Vickers ElectronicProducts leaflet 2468. Wiring practices relevant to this Directive are indicated byElectromagnetic Compatibility (EMC). Power Plugs for Proportional ValvesVickers Amplifier Cards2 Operating DataElectricalTypes D and JType KConnections123424V DC0V ( Power and signal)Positive command signalNegative command signalPower (input) supply20-30V DC including "10% maximum ripple (peak-to-peak)24V DC nominalAbsolute maximum voltage40 VMax. Power consumption incl. solenoid35 WReverse polarity protectedYesShort circuit protectedYesMaximum output current1,6 AMax. output voltage typical (1,6A outputcurrent)Typically 1,5V below supply voltageCommand signal0-10V (10 kohms)4-20 mA (250 ohms)Deadband triggeringFor output (LED ON)For no output (LED OFF)200 mV200 mV to 10V0 mV to 100 mV4 mA4-20 mA0-4 mADeadband adjustment range100 to 1000 mAGain adjustment A/V to A/mA to A/mADither adjustment range0 to 500 mARamp time (types D and K only)50 ms to 5sPWM frequency1200 Hz "10%Dither frequency120 Hz "10%ProtectionIEC 529: IP67 (when correctly installed with interface seal in place)Fully short-circuit and reverse-polarity protectedIsolation to VDE 0110 Group B Electromagnetic compatibility (EMC):EmissionImmunityEN 50081-2EN 50082-2 MechanicalHousingPA6 glass-reinforced plastic (conforming to UL-94HB).

4 Color: grayMounting interfaceISO 4400 (DIN 43650)Cable clampPg9 screw typeCable diameter 5 to 10 mm ( to dia)Wire section0,5 to 1,0 mm2 (20 AWG-17 AWG)Temperature, ambient range 20_ to +70_C ( 4_ to +158_F)Mass0,07 kg ( lb)Type J10V8V6V4V2 VCommandsignalOutputcurrentRampsettingTi meTimeDeadband compensationUS Gain settingInput/Output CharacteristicsTypes D and K20 mA12 mA4 mAType K Type D10V8V6V4V2 VCommandsignalvoltage UsOutputcurrentTimeTimeDeadband compensationUS Gain settingSolenoid Connections3rd angleprojectionInstallation Dimensions in mm (inches)1288 ( )39( )22( )34 ( )38( )No connection1 (or 2)2 (or 1)3 installation Data1234 LEDD itherDeadbandGainRampAdjustmentsRamp time:Turn clockwise to increase ramp time.(Only types D/K)Gain:Turn clockwise to increase compensation:Turn clockwise to increase deadbandcompensation :Turn clockwise to increase the 1: Power supply 20V-30V DC, 2: Power supply 3:Command signal positive (see Operating Data ).

5 Terminal 4:Command signal negative (see Operating Data ). installation Wiring OptionsPositive Command Voltage123424V0V0V123424V0V0V+10V 10 VEHH-AMP-702-D/J-20 EHH-AMP-702-D/J-20123424V0V0 VEHH-AMP-702-K-204-20 mANegative Command Voltage4-20 mA Command Signal123424V0V0V123424V0V0V 10V+10 VEHH-AMP-702-D/J-20 EHH-AMP-702-D/J-20Bi-polar Command Voltage for OperatingTwo Solenoids from One SignalCustomer s protective ground when replacing 10 design Power plugwith 20 design and only 3 wires exist123424V0V0 VEHH-AMP-702-D/J/K-20 Link pin 2 to pin 4 Warning: Electromagnetic Compatibility (EMC)Screened cables should be used and particular attention paid to the grounding of the screens as shown in the above Showing Wiring Connection PointsFEnsure cable clamp nut is adequatelytightened to secure the not connect, or disconnect, theplug while Power is not mount, or dismount, the plugwhile Power is 0,5-1,0 mm2(20 AWG-17 AWG)5 ( )40 ( )Wiring Preparation 5-10( dia)JJWarningJAll seals must be fitted correctly at pluginstallation to provide protection to IP67 (IEC 529).

6 5 installation Data6 Start-Up ProcedureFCorrectly wire the plug and, beforemounting it on the valve solenoid,apply 24V DC (20 to 30V limits) to the Power input for correct plug function byillumination/non-illumination of theLED. The LED should illuminate whenthe demand applied to the signalinput terminal is between 200 mV and10V (or 4 mA and 20 mA) and shouldnot be illuminated when the applieddemand is less than 100 mV (4 mA). Ifthere is a malfunction a new plug mustbe off Power supply andcommand/input signal and then installplug on solenoid. Ensure that all sealsare fitted correctly and clamped as theretaining screw is tightened: this isessential in providing IP67 that the hydraulic system willnot cause any erratic movement ofactuators, then: Switch on Power supply again. Repeat LED/function check as in LED malfunction now indicates ashort circuit at the completion of thesechecks means that the plug and loadare ready for PartsThe only spare part available is theinterface seal, part number ProcedureOrder plug by full model code, and spareinterface seals by part number 732100.