Vickers . Directional Controls Lever Operator Directional control valves DG17S-8-**-10. DG17S4-10 **-50. NFPA D08/D10, ISO-4401-08/10. Released 5/94 681. Table of Contents General Information .. 4. DG17S-8 Basic Characteristics Installation Data Mounting Interface Shifting Action DG17S4-10 Basic Characteristics Mounting Interface Shifting Action Mounting Position Service Information Model Code DG17S-8 .. 5. DG17S-8 Maximum Flow Rating DG17S-8 Recommended Flow Rating .. 6. Oil Flow Directions DG17S-8 Pressure Drop .. 7. DG17S-8 Installation Dimensions .. 8. DG17S-8 Subplates & Bolt Kits .. 9. Model Code DG17S4-10.

Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NFPA D08/D10, ISO-4401-08/10 Released 5/94 681 Vickers® Directional Controls

Tags:

  Control, Operator, Valves, Directional, Lever, Lever operator directional control valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Vickers Directional Controls Lever Operator …

1 Vickers . Directional Controls Lever Operator Directional control valves DG17S-8-**-10. DG17S4-10 **-50. NFPA D08/D10, ISO-4401-08/10. Released 5/94 681. Table of Contents General Information .. 4. DG17S-8 Basic Characteristics Installation Data Mounting Interface Shifting Action DG17S4-10 Basic Characteristics Mounting Interface Shifting Action Mounting Position Service Information Model Code DG17S-8 .. 5. DG17S-8 Maximum Flow Rating DG17S-8 Recommended Flow Rating .. 6. Oil Flow Directions DG17S-8 Pressure Drop .. 7. DG17S-8 Installation Dimensions .. 8. DG17S-8 Subplates & Bolt Kits .. 9. Model Code DG17S4-10.

2 10. DG17S-8 Maximum Flow Rating DG17S4-10 Pressure Drop .. 11. DG17S4-10 Installation Dimensions .. 12. DG17S4-10 Subplates & Bolt Kit .. 13. Application Data .. 14. 2. Introduction General Description Features and Benefits These valves are generally used to Suitable for the most demanding control the direction of flow in a industrial applications with flow hydraulic circuit. This, in turn, would capacities up to 380 l/min (100. control the direction of movement of a USgpm) and rated pressure of hydraulic cylinder, or the rotation of a 210 bar (3000 psi). fluid motor. High pressure and flow capability for DG17S-8 Lever Operated maximum cost-effectiveness.

3 DG17S4-10 Lever Operated Low shock characteristics to maximize machine life. Solid cast body and core passages for maximum strength and minimal pressure drop. Designed and backed by Vickers , with over 70 years as the global leader in fluid power and motion control . 3. General Information DG17S-8 Basic DG17S4-10 Basic Characteristics Characteristics CAUTION. Max. pressure: 210 bar (3000 psi) Max. pressure: 210 bar (3000 psi). Max. flow: 380 l/min (100 USgpm) Max. flow: 341 l/min (90 USgpm) Surges of oil in a common tank line Max. pressure port T: Max. pressure port T: serving these and other valves can.

4 140 bar (2000 psi) .. 210 bar (3000 psi) be of sufficient magnitude to cause Weight spring centered/detented: Weight: .. 42,6 kg (94 lbs.) inadvertent shifting of these valves .. 13,5 kg ( lbs.) Weight (Subplate): This is particularly critical in the Weight spring offset: .. 17,2 kg (38 lbs.) no-spring detented type valves .. 15 kg (33 lbs.) Separate tank lines or a vented The DG17, Lever operated valves are manifold with a continuous Installation Data ideally suited for applications requiring a downward path to tank is necessary. manually operated, four-way Directional Drain connection must be piped directly to valve.

5 Tank through a surge free line so there will Mounting Position be no back pressure at this port. Mounting Interface No-spring detented valves must be installed with the longitudinal axis Mounting Interface ISO 4401-10 horizontal for good machine reliability. NFPA D10 The mounting position of spring-offset ISO 4401-08. models is unrestricted. NFPA D08 Port connections are made by mounting CETOP 8 the valves on a subplate or manifold Drain connection must be piped directly to having mounting dimensions which tank through a surge free line so there will Port connections are made by mounting conform to NFPA-D10 (ISO-4401-10) be no back pressure at this port.

6 valves on a subplate or manifold having pattern. mounting dimensions which conform to NOTE. NFPA-D08 (ISO-4401-08) pattern. Any sliding spool valve, if held for Shifting Action long periods of time, may stick and not spring return due to fluid residue Spring offset valves are spring formation and therefore, should be positioned unless Lever is actuated. cycled periodically to prevent this No-spring detented valves maintain the from happening. spool position last selected. Machine vibration, heat, improper circuitry and externally induced shocks may cause Service Information no-spring detented valves to shift Refer to specific Vickers parts drawing for prematurely.

7 Service parts information. A complete parts breakdown is contained in this drawing. Spring centered models return valve Order by literature number. spool to center position by centering DG17S-8-*A/C/N .. I-3441-S. springs when Lever pressure falls below DG17S-10-50 .. I-3564-S. minimum requirement. 4. Lever Operated Directional valves Model Code 1 2 3 4 5 6. 1 Directional control 3 Spool Types 5 Design Number Manifold or subplate mounted; manual 0, 2, 3, 4, 6, 8, 33 - (See flow rating Subject to change. Installation Lever operated; 4-way flow direction. tabulations for descriptions.) dimensions remain as shown for design Rated pressure 210 bar (3000 psi).

8 Numbers 10 through 19 models. 4 Spool/Spring Arrangement 2 Interface 6 Spring Offset Model A - Spring offset NFPA-D08 (ISO-4401-08) C - Spring centered LH - Offset to B. (Omit for offset to A. 8 - Flow 380 l/min (100 USgpm) N - No-spring detented models shown.). DG17S-8 Max. Flow Rating 70 bar (1000 psi) 140 bar (2000 psi) 210 bar (3000 psi). Model Model Model Model Model Model Model Model Model Model Code -C- -A- -N- -C- -A- -N- -C- -A- -N- l/min l/min l/min l/min l/min l/min l/min l/min l/min (USgpm) (USgpm) (USgpm) (USgpm) (USgpm) (USgpm) (USgpm) (USgpm) (USgpm). DG17S-8-0C-10. 380 380 380 303 380 380 227 380 380.

9 DG17S-8-0A-10. (100) (100) (100) (80) (100) (100) (60) (100) (100). DG17S-8-0N-10. DG17S-8-2C-10. 380 265 380 380 265 380 380 265 380. DG17S-8-2A-10. (100) (70) (100) (100) (70) (100) (100) (70) (100). DG17S-8-2N-10. DG17S-8-3C-10 380 380 380 380 380 265 380. DG17S-8-3N-10 (100) (100) (100) (100) (100) (70) (100). DG17S-8-4C-10 303 380 303 380 303 380. DG17S-8-4N-10 (80) (100) (80) (100) (80) (100). DG17S-8-6C-10. 380 190 380 380 133 380 380 95 380. DG17S-8-6A-10. (100) (50) (100) (100) (35) (100) (100) (25) (100). DG17S-8-6N-10. DG17S-8-8C-10 303 380 303 380 303 380. DG17S-8-8N-10 (80) (100) (80) (100) (80) (100).

10 DG17S-8-33C-10. 380 190 380 380 133 380 380 95 380. DG17S-8-33A-10. (100) (50) (100) (100) (35) (100) (100) (25) (100). DG17S-8-33N-10. 5. DG17S-8 Flow Ratings Spring Centered Spring Offset No-Spring Detented Recommended -C- -A- -N- Standard Spool Types Flow Capacity at 210 bar All Spools 0, 2, 6 & 33 All Spools (3000 psi). AB A B A B Center Position & Description l/min P T P T PT 123. Spool Type Center Position (USgpm). A B. Opens to T 170. DG17S-8-0C-10 DG17S-8-0A-10 DG17S-8-0N-10 0 . all ports (45). P T. A B. Closed to T 170. DG17S-8-2C-10 DG17S-8-2A-10 DG17S-8-2N-10 2 . all ports (45). P T.