Transcription of Vickers Flow Controls - Eaton
1 Service Data Vickers . Flow Controls Modular Flow Regulator Valves dgfn -06-50. 349156 Plug 292761 Check Valve 253369 Stop (Check Valve). (2 req'd) (2 req'd) (2 req'd). 166886 Nut 292502 Spring Y262330 O'' Ring (2 req'd) (2 req'd) (2 req'd). 349157 Guide 253317 Screw (2 req'd) (2 req'd). Y263498 O'' Ring (2 req'd). 349153 Plate Y154014 O'' Ring (2 req'd). 36212 Screw (2 req'd). Y154019 O'' Ring (2 req'd) Name Plate CAUTION. 199312 Rollpin The valve cannot be used (2 req'd). with pressure centered or DG-18 Air Operated Valves. Note Refer to installation drawing 522650 for bolt kit information and module stacking data. The mounting bolt torque should not exceed a maximum of 700 in. lbs. (79 ). YIncluded in 919646 Seal Kit Note The following subplates may be used to mount a 60 series directional valve and one or more modular valves: DGSM-06-50 (3/4 inch NPT) Assy. No 280497. DGSM-06X-50 (1 inch NPT) Assy.
2 No. 280498. DGSM-06Y-50 (1-1/4 inch NPT) Assy. No. 315213. Revised 11/01/85 I-3384-S. Model Code 1 2 3. 1 Model Series 2 Size 3 Design dgfn - Directional control, gasket 06 - 3/4 inch mounted flow regulator module For satisfactory service life of these components, use full flow filtration to provide fluid which meets ISO cleanliness code 18/15. or cleaner. Selections from Eaton OFP,OFR and OFRS filter series are recommended. Printed in 2.