Transcription of Vickers Vane Pumps Service Data - Eaton
1 Vickers Vane PumpsService DataEATON Vickers Vane Pumps M-2010-S November 20112 Vane PumpV20NF-**T-**-22V20NF-**T-**C-22V20NF -**T-**D-22V20NF-**T-**E-22V20NF-**T-**F -22V20NF-**T-**G-22V20NF-**T-**H-22V20NF -**T-**J-22V20NF-**T-**K-22V20NF-**T-**L -22396098 O Ring109975 Retaining Ring396098 O Ring239766 SpringControl Valve S/A(See table)Screw (4 req d) (See table) Torque 75-85 lb. O RingBody (See table)279499 Shaft Seal577701 Wave WasherKey (See table) - Included in Seal Kit 920371 ModelBodyV20NF-1DV20NF-4DV20NF-1FV20NF-1 PV20NF-4PV20NF-1S58317058317229722828068 9308628294266 ModelCoverV20NF-**T-**2*-22V20NF-**T-**3 *-22V20NF-**T-**4*-22V20NF-**T-**5*-22V2 0NF-**T-**6*-22V20NF-**T-**7*-22V20NF-** T-**8*-22V20NF-**T-**9*-22V20NF-**T-**10 *-22452272452240452242452069452244574959 452071478133452274 ModelControlValve S/A2327942327952327962327972327982327992 33019233020266200 - Included in Cartridge KitModelScrewV20NF-**5TV20NF-**6TV20NF-* *7TV20NF-**8TV20NF-**9TV20NF-**10TV20NF- **11TV20NF-**12TV20NF-**13T166629603 PinVaneKit11165923651 Cartridge Kit5031574522354522615749544522644522675 7494545227045224592365692365792365892365 9923660923661923662923663923664
2 ModelShaftV20NF-**T-1V20NF-**T-3V20NF-** T-6V20NF-**T-10V20NF-**T-11V20NF-**T-38V 20NF-**T-101V20NF-**T-103V20NF-**T-138V2 0NF-**T-203V20NF-**T-2382803722805042973 3032404328051532809647814247813647812250 2682502235 KeyNut5881161516091609588116151615132260 586589 O RingPin (2 req d) (See table)98653 Retaining Ring98574 Bearing205840 Pin374865 Plug574958 Pressure Plate S/A513408 O Ring374865 Plug374865 Plug586589 O RingRing & Rotor S/A (See table)Vane Kit (See table)FB-A-10 Foot Bracket Kit (Optional)Shaft (See table)Nut (See table)2161247896168961689431923653923654 923652 Cover (See table) Eaton Vickers Vane Pumps M-2010-S November 20113 Model CodeV20NF - * * * T - * * * * 22 - (* * *) - (L)110121123456789 Model Series V20NF Vane pump, 20 size with flow control valve cover & internal drain Pump Mounting 1 2 Bolt 2 Foot mount - body inlet port @ 12 o clock (viewed from shaft end) 3 Power take off 4 Face 23 Body inlet port @ 3 o clock 26 Body inlet port @ 6 o clock 29 Body inlet port @ 9 o clock Inlet Body Port D (SAE straight thread) F 2 bolt flange P S (straight thread) Ring Capacity @ 1200 RPM5 -5 GPM 8 -8 GPM 11-11 GPM 6 -6 GPM 9 -9 GPM 12-12 GPM 7 -7 GPM 10 -10 GPM 13-13 GPM Flow Control Cover (Pressure port.)
3 750-16 straight thread) Shaft Extension Type For 10-13 GPM units: 1 Straight keyed (standard) 3 Threaded 6 Straight Stub 10 Threaded Straight Stub 11 Splined 38 Splined For 7-9 GPM units: 101 Straight keyed (standard) 103 Threaded 138 Splined For 5-6 GPM units: 203 Threaded 238 Splined Outlet pressure port position (Viewed from cover end) A Opposite inlet port B 90 CCW from inlet port C In line with inlet port D 90 CW from inlet port Flow Rate thru Orifice in Cover2 - 2 GPM 7 - 7 GPM 3 - 3 GPM 8 - 8 GPM 4 - 4 GPM 9 - 9 GPM 5 - 5 GPM 10 - 10 GPM 6 - 6 GPM Control Valve Pressure SettingC - 750 PSI H -2000 PSI D - 1000 PSI J -2250 PSI E - 1250 PSI K -2500 PSI F - 1500 PSI L -2750 PSI G- 1750 PSI Design Special Suffix Feature (Omit if not required.) Left Hand Rotation (Viewed from shaft end) (Omit for right hand rotation.
4 178910111223456 For satisfactory Service life of these components, use full flow filtration to provide fluid which meets ISO cleanliness code 18/15 or cleaner. Selections from Eaton OFP,OFR and OFRS filter series are Hydraulics Group USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952-937-9800 Fax: 952-294-7722 Hydraulics Group Europe Route de la Longeraie 7 1110 Morges Switzerland Tel: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Hydraulics Group Asia Pacific Eaton Building 4th Floor, No. 3 Lane 280 Linhong Rd. Changning District Shanghai 200335 China Tel: (+86 21) 5200 0099 Fax: (+86 21) 5200 0400 2011 Eaton Corporation All Rights Reserved Printed in USA Document No. ???????????? November 2011