TM 11-5830-263-10 TECHNICAL MANUALOPERATOR'S MANUALINTERCOMMUNICATION SET, VEHICULARAN/VIC-3(V), INCLUDING:Control, Indicator CD-82/VRC(NSN 5895-01-382-3221) (EIC: NA)Control, Intercommunication Set C-12357/VRC(NSN 5830-01-382-3218) (EIC: NA)Control, Intercommunication Set C-12358/VRC(NSN 5830-01-382-3209) (EIC: NA)Interface Unit, Communication Equipment C-12359/VRC(NSN 5895-01-382-3220) (EIC: NA)Loudspeaker, Permanent Magnet, LS-688/VRC(NSN 5965-01-382-3222) (EIC: NA)Approved for public release; distribution is NOTICE -- Destroy by any method that will preventdisclosure of contents or reconstruction of the documentHEADQUARTERS, DEPARTMENT OF THE ARMY1 MAY 1997 VISTM-11-5830-263-10 I01 CHANGE HEADQUARTERS DEPARTMENT OF THE AR MY No. I01 WASHINGTON, DC, 1 MAY 2003 EXPIRES 1 MAY 2004 OPERATOR'S MANUAL for INTERCOMMUNICATION SET, VEHICULAR AN/VIC-3(V) Control, Indicator CD-82/VRC (NSN 5895-01-382-3221) (EIC: NA) Control, Intercommunication Set C-12357/VRC (NSN 5830-01-382-3218) (EIC: NA) Control, Intercommunication Set C-12358/VRC (NSN 5830-01-382-3209) (EIC: NA) Interface Unit, Communication Equipment C-12359/VRC (NSN 5895-01-382-3220) (EIC: NA) Loudspeaker, Permanent Ma

A/(B blank) TM 11-5830-263-10 LIST OF EFFECTIVE PAGES/WORK PACKAGES Dates of issue for the original manual and changed pages/work packages are:

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of VIS - liberatedmanuals.com

1 TM 11-5830-263-10 TECHNICAL MANUALOPERATOR'S MANUALINTERCOMMUNICATION SET, VEHICULARAN/VIC-3(V), INCLUDING:Control, Indicator CD-82/VRC(NSN 5895-01-382-3221) (EIC: NA)Control, Intercommunication Set C-12357/VRC(NSN 5830-01-382-3218) (EIC: NA)Control, Intercommunication Set C-12358/VRC(NSN 5830-01-382-3209) (EIC: NA)Interface Unit, Communication Equipment C-12359/VRC(NSN 5895-01-382-3220) (EIC: NA)Loudspeaker, Permanent Magnet, LS-688/VRC(NSN 5965-01-382-3222) (EIC: NA)Approved for public release; distribution is NOTICE -- Destroy by any method that will preventdisclosure of contents or reconstruction of the documentHEADQUARTERS, DEPARTMENT OF THE ARMY1 MAY 1997 VISTM-11-5830-263-10 I01 CHANGE HEADQUARTERS DEPARTMENT OF THE AR MY No. I01 WASHINGTON, DC, 1 MAY 2003 EXPIRES 1 MAY 2004 OPERATOR'S MANUAL for INTERCOMMUNICATION SET, VEHICULAR AN/VIC-3(V) Control, Indicator CD-82/VRC (NSN 5895-01-382-3221) (EIC: NA) Control, Intercommunication Set C-12357/VRC (NSN 5830-01-382-3218) (EIC: NA) Control, Intercommunication Set C-12358/VRC (NSN 5830-01-382-3209) (EIC: NA) Interface Unit, Communication Equipment C-12359/VRC (NSN 5895-01-382-3220) (EIC: NA) Loudspeaker, Permanent Magnet LS-688/VRC (NSN 5965-01-382-3222) (EIC: NA) TM 11-5830-263-10, 1 May 1997, is changed as follows: 1.

2 New or changed text is indicated by a vertical bar in the margin of the page. 2. Remove old pages and insert new pages: Remove Pages Insert Pages A/(B blank) A/(B blank) None c/(d blank) 2-9/2-10 2-9/2-10 None ( blank) 2-11/2-12 2-11/2-12 2-19/2-20 2-19/2-20 None ( blank) 3-3/3-4 3-3/3-4 thru ( blank) 3. File this sheet in front of the publication for reference purposes. Approved for public release; distribution is unlimited. By Order of the Secretary of the Army: ERIC K. SHINSEKI General, United States Army Official: Chief of Staff DISTRIBUTION: To be distributed in accordance with the initial distribution number (IDN) 369732 requirements for TM 11-5830-263-10. 05985TM 11-5830-263-10C1 CHANGEHEADQUARTERS,DEPARTMENT OF THE ARMYNO. 1 WASHINGTON, 1 JULY 2000 OPERATOR'S MANUALforINTERCOMMUNICATION SET, VEHICULAR AN/VIC-3(V)Control, Indicator CD-82/VRC(NSN 5895-01-382-3221) (EIC: NA)Control, Intercommunication Set C-12357/VRC(NSN 5830-01-382-3218) (EIC: NA)Control, Intercommunication Set C-12358/VRC(NSN 5830-01-382-3209) (EIC: NA)Interface Unit, Communication Equipment C-12359/VRC(NSN 5895-01-382-3220) (EIC: NA)Loudspeaker, Permanent Magnet LS-688/VRC(NSN 5965-01-382-3222) (EIC: NA)TM 11-5830-263-10, 1 May 1997, is changed as follows:1.

3 New or changed text is indicated by a vertical bar in the margin of the Remove old pages and insert new pages:Remove PagesInsert PagesNoneA and B(blank)i and iii and iiBlank and 1-0iii and 1-01-3 and 1-41-3 and 1-41-7 thru 1-101-7 thru 1-101-11/(1-12 blank)None2-19 and 2-202-19 and 2-203-1 thru 3-43-1 thru and thru A-4A-1 thru A-4 Cover 1 Cover 23. File this sheet in front of the publication for reference purposes. By Order of the Secretary of the Army: ERI C K. SHINSEKI General, United States Army Official: Chief of Staff 0022310 DISTRIBUTION: To be distributed in accordance with the initial distribution number (IDN) 369732 and special requirements for TM 11-5830-263-10.

4 A/(B blank) TM 11-5830-263-10 LIST OF EFFECTIVE PAGES/WORK PACKAGES Dates of issue for the original manual and changed pages/work packages are: Original 1 May 97 Change 1 1 July 00 Change I01 1 May 03 TOTAL NUMBER OF PAGES FOR FRONT AND REAR MATTER IS 18 AND TOTAL NUMBER OF WORK PACKAGES IS 0, CONSISTING OF THE FOLLOWING: Page/WP No. *Change No. Cover/blank 1 A/(B blank) I01 a/b) 0 c/(d blank) I01 i and ii 1 iii 1 1-0 0 Chapter 1 1-1 and 1-2 0 1-3 1 1-4 thru 1-7 0 1-8 1 1-9 1 1-10 0 1-11 and 1-12 Deleted 1 Chapter 2 2-1 thru 2-9 0 2-10 I01 and I01 2-11 I01 Page/WP No. *Change No. 2-12 thru 2-18 0 2-19 and 2-20 I01 ( blank) and I01 2-21 thru 2-40 0 Chapter 3 3-1 0 3-2 1 3-3 and 3-4 I01 thru ( blank) I01 3-5 and 3-6 0 A-1 thru A-3 1 A-4 0 B-1 and B-2 0 C-1 and C-2 0 D-1 and D-2 0 E-1 and E-2 0 *Zero in this column indicates an original page.

5 TM 11-5830-263-10aSAFETY STEPS TO FOLLOW IF SOMEONEIS THE VICTIM OF ELECTRICAL SHOCKDO NOT TRY TO PULL OR GRAB THE INDIVIDUALIF POSSIBLE, TURN OFF THE ELECTRICAL POWERIF YOU CANNOT TURN OFF THE ELECTRICALPOWER, PULL, PUSH, OR LIFT THE PERSON TOSAFETY USING A DRY WOODEN POLE OR A DRYROPE OR SOME OTHER INSULATING MATERIALSEND FOR HELP AS SOON AS POSSIBLEAFTER THE INJURED PERSON IS FREE OF CONTACTWITH THE SOURCE OF ELECTRICAL SHOCK, MOVETHE PERSON A SHORT DISTANCE AWAY AND IMME-DIATELY START ARTIFICIAL RESUSCITATION5 Change 1 COMPARTMENT2345TM 11-5830-263-10bWARNINGHIGH VOLTAGEIS USED IN THE OPERATION OF THIS ON CONTACTMAY RESULT IF PERSONNEL FAIL TO OBSERVESAFETY NOT BE MISLED BY THE TERM "LOW VOLTAGE".POTENTIALS AS LOW AS 30 VOLTS MAY CAUSE DEATH UNDERCERTAIN ARTIFICIAL RESPIRATION, REFER TO FM LISTENING TO THE VIS RADIO HEADSET WITH THEOPERATOR VOLUME CONTROLS SETTING IN THE RED ZONE CLICKSTOP AT A FULL ON VOLUME SETTING, EXTREME CAUTION MUST BEEXERCISED TO PREVENT NOISE-INDUCED HEARING TO RADIO SIGNALS IN THE FULL ON POSITION BEYOND45 SECONDS MAY CAUSE HEARING LOSS.

6 ANY PROLONGEDEXPOSURE IN THE FULL ON VOLUME CONTROL SETTING REQUIRESTHE USE OF A SINGLE HEARING PROTECTIVE DEVICE IN EACH BATTERIES CONTAIN CAUSTIC KOH ELECTROLYTE,WHICH MAY LEAK IF THE BATTERY IS ABUSED. KOH IS A STRONGALKALI SIMILAR TO CAUSTIC SODA (SODIUM HYDROXIDE). SERIOUSCHEMICAL BURNS CAN RESULT IF ELECTROLYTE COMES INTOCONTACT WITH THE SKIN OR EYES. IF THE BATTERY ELECTROLYTEGETS INTO YOUR EYES, IT CAN CAUSE SEVERE DAMAGE NOT TRY TO NEUTRALIZE CAUSTIC ELECTROLYTE WITHVINEGAR OR ANY OTHER ACIDIC SOLUTIONS. NEUTRALIZATIONWILL DO MORE HARM THAN GOOD, AS IT WILL TRAP CAUSTICUNDER THE SKIN, PREVENTING IT FROM COMING OUT. FLUSH WITHCOPIOUS AMOUNTS OF COOL 11-5830-263-10 Change I01 c/(d blank) WARNING DISCONNECTING OR BYPASSING THE VEHICULAR INTERCOMMUNICATION SYSTEM (VIS) ALARM CABLE CONNECTED TO THE DRIVER S FULL FUNCTION CREW STATION (FFCS) BY THE VEHICLE CREWMAN IS PROHIBITED.

7 SUCH ACTION MAY RESULT IN INJURY OR DEATH. EQUIPMENT DAMAGE MAY ALSO RESULT. THIS CABLE ENABLES THE VEHICLE HAZARD WARNING TONES TO BE INSERTED DIRECTLY INTO THE INTERCOM SYSTEM, SO THAT THESE WARNING TONES CAN BE INSTANTLY HEARD BY ALL OF THE VEHICLE CREWMEMBERS. ONLY THE UNIT MAINTAINER IS AUTHORIZED TO REMOVE AND REPLACE THE ALARM CABLE. REFER TO THE APPROPRIATE VIS TECHNICAL PUBLICATIONS FOR OPERATOR, INSTALLATION, AND MAINTENANCE INSTRUCTIONS. Technical ManualTM 11-5830-263-10iHeadquartersDepartment of the ArmyTM 11-5830-263-10 Washington, DC, 1 May 1997 OPERATOR'S MANUALforINTERCOMMUNICATION SET, VEHICULAR AN/VIC-3(V)Control, Indicator CD-82/VRC(NSN 5895-01-382-3221) (EIC: NA)Control, Intercommunication Set C-12357/VRC(NSN 5830-01-382-3218) (EIC: NA)Control, Intercommunication Set C-12358/VRC(NSN 5830-01-382-3209) (EIC: NA)Interface Unit, Communication Equipment C-12359/VRC(NSN 5895-01-382-3220) (EIC: NA)Loudspeaker, Permanent Magnet LS-688/VRC(NSN 5965-01-382-3222) (EIC: NA)TABLE OF CONTENTSPageHow To Use This I.

8 General II. Principles of III. Equipment Description and IV. Training 2 Operating I. Controls and II. Operating Procedures Under Normal III. Operation Under Unusual ERRORS AND RECOMMENDING IMPROVEMENTSYou can help improve this manual. If you find any mistakes, or if you know of a way to improve theprocedures, please let us know. Mail your letter, DA Form 2028 (Recommended Changes toPublications and Blank Forms) or DA Form 2028-2 located in back of this manual direct to:Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN:AMSEL-LC-LEO-D-CS-CFO, Fort Monmouth, New Jersey 07703-5007. The fax number is732-532-1413, DSN 992-1413. You may also e-mail your recommendations Air Force, submit AFTO Form 22 (Technical Order System Publication Improvement Report andReply) in accordance with paragraph 6-5, Section VI, TO 00-5-1.

9 Forward direct to prime Navy, mail comments to the Commander, Space and Naval Warfare Systems Command, ATTN:SPAWAR 8122, Washington, DC Corps units, submit NAVMC 10772 (Recommended Changes to Technical Publications) to:Commanding General, Marine Corps Logistics Base (Code 850), Albany, Georgia either case a reply will be furnished direct to 1TM 11-5830-263-10iiTABLE OF CONTENTS (continued) PageChapter 3 Operator Maintenance ..3-1 Section I. Operator Preventive Maintenance Checks and Services (PMCS).3-1 Section II. Operator Troubleshooting ..3-5 APPENDIX A ..A-1 APPENDIX B COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS B-1 APPENDIX C ADDITIONAL AUTHORIZATION ..C-1 APPENDIX D EXPENDABLE/DURABLE SUPPLIES AND MATERIALS ..D-1 APPENDIX E ACRONYMS AND ..E-1 Change 1TM 11-5830-263-10iiiLOCATING INFORMATIONTABLE OF CONTENTS.

10 Refer to the Table of Contents to find out whereinformation can be Refer to the list of abbreviations in Appendix E in the backof this manual to find the term associated with an unfamiliar CROSS-REFERENCE LIST. Refer to the nomenclaturecross-reference list in Table 1-1 on page 1-2 to find common names andofficial PAGES are at the beginning of this manual. You should learn thewarnings before using the equipment Always follow appropriate safetyprocedures and TO USE THIS MANUALC hange 1TM 11-5830-263-10 LINESACCENTSYSTEMLISTENINGSILENCEPROG 1 ALLPROG 2 PROG 3 POWER FAULTCHANGELOUDSPEAKERSYSTEMOFFPROGRAMVI EWSTATIONFUNCTIONRADIOPOWERLOUDSPEAKERAL ARMSLINESLINESRADIOINTOFFSYSANRSTATIONST ATIONSTOREONOFFONOFFFULL FUNCTION CREWSTATION (FFCS)RADIO INTERFACETERMINAL (RIT)LOUDSPEAKER(LS)MONITOR ONLYSTATION (MOS)MASTER CONTROLSTATION (MCS)1-0TM 11-5830-263-101-1 CHAPTER 1 INTRODUCTIONPageSection Information.