Technical Instructions - Watts Water

Back to document page

109/14/2007The Hydroguard XP LFMM430 series is a temperature actuated mixing valve designed for use in hot Water distribution systems, in compliance with ASSE Operating Pressure ............. 125 psi (861 kPa)Maximum Hot Water Temperature .......200 F (93 C)Minimum Hot Water Supply Temp ....... 5 F (3 C) Above Set-Point*Temp. Adjustment Ranges ** Standard:............................... ......... 90 - 160 F (32 - 71 C) Low: ........................................ ............. 60 - 90 F (16 - 32 C)Hot Water Inlet Temperature Range .....120 -180 F (49 - 82 C)Cold Water Inlet Temperature Range ... 40 - 80 F (4 - 27 C) ASSE 1017Certified ........................................ ............ CSA B125* With Equal Pressure** Low limit cannot be less than the cold Water temperature. For best operation, hot Water should be at least 5 F (3 C) above desired set nHYDROGUARD XP Master Tempering Valves Series LFMM430 Technical InstructionsIS-P-MM430Advanced Thermal ActivationWARNING!

1. Installation should be in accordance with acceptable plumb-ing practices. Flush all piping thoroughly before installation. Installation and field adjustment are the responsibility of the

  Installation, Instructions