Transcription of Process Control of Ionic Contamination Achieving …
{{id}} {{{paragraph}}}
Process Control of Ionic Contamination Achieving 6- sigma criteria in The Assembly of electronic Circuits P. Eckold[1], M. Routley[2], L. Henneken[1], G. Naisbitt[2], R. Fritsch[1], U. Welzel[1] [1]Robert Bosch GmbH, Automotive Electronics, Stuttgart, Germany[2]Gen3 Systems Limited, Farnborough, UKAbstract Ionic Contamination testing as a Process Control tool a newly developed testing protocol based on IPC-TM 650 , was established to enable monitoring of Ionic Contamination within series production. The testing procedure was successfully implemented within the production of high reliability, safety critical electronic circuits, involving multiple production sites around the world. I will be shown in this paper that the test protocol is capable for meeting Six- sigma - criteria .
Process Control of Ionic Contamination Achieving 6-Sigma Criteria in The Assembly of Electronic Circuits P. Eckold [1], M. Routley[2], L. Henneken , G. Naisbitt[2], R. Fritsch[1], U. Welzel [1] Robert Bosch GmbH, Automotive Electronics, Stuttgart, Germany [2] Gen3 Systems Limited, Farnborough, UK Abstract Ionic contamination testing as a process control …
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
Cleanroom Considerations for ESD Control, CONTROL, Cardiac Implantable Electronic Device Infection in, Electronic, Infection control Oversee cleaning of, APIC Statement on Recently, APIC Statement on Recently Presented Research on Electronic, For Detection of Fecal Contamination of Drinking Water, Food hygiene, Electrostatic Liquid Cleaning does efficiently