G2RL - Omron
PCB Power Relay Low profile power relay with 15.7 mm height, ideal for incorporation in miniature equipments • A wide variety of single pole, double pole, high-capacity (16 A) type and high-sensitivity type (250 mW) relays are available. • IEC/EN 60335-1 conformed. (-HA Model) • Satisfies ambient operating temperature requirement of 85°C
Download G2RL - Omron
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
CSM PCB Con CN J 1 3 - omronfs.omron.com
omronfs.omron.comA-20 最新の商品情報・便利な情報は www.fa.omron.co.jp/ コネクタ 共通の注意事項 コネクタ 共通の注意事項 挿抜作業について ・通電中の挿抜作業時および抜去後に、コネクタの接点 …
CSM XM2 XM3 AC DS J 1 8 - omronfs.omron.com
omronfs.omron.com2 最新の商品情報・便利な情報は www.fa.omron.co.jp/ XM2/XM3 Dサブコネクタ X M 2 / X M 3 注1. 1個のコネクタに固定具は2個必要です。 注2. 形XM3K/Lには取付できません。
Solid State Pressure Sensors D8M - omronfs.omron.com
omronfs.omron.comCompact D8M solid state pressure sensors provide reliable detection for gas and air inflow for burner controls in water heaters, furnaces and other gas-fired devices.
G5V-2 - omronfs.omron.com
omronfs.omron.com2 G5V-2 Low Signal Relay G 5 V-2 Ratings Coil Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C.
G6B - Omron
omronfs.omron.com3 G6B PCB Power Relay G 6 B Models for Ultrasonically Cleanable Note: When ordering, add the rated coil voltage to the model number. Example: G6B-1114P-US DC5 However, the notation of the coil voltage on the produc t case as well as on the packing will be marked as @@ VDC.
Solid State Relays Common Precautions
omronfs.omron.com2.Inductive Noise Do not wire power lines alongside the input lines. Inductive noise may cause the SSR to malfunction. If inductive noise is imposed on the input terminals of the SSR, use the following cables according to the type of inductive noise, and reduce the noise level to less than the must release voltage of the SSR.
DC Power Relays
omronfs.omron.comHigh-voltage, High-current Loads • A compact relay (73 x 36 x 67.2 mm (L x W x H)) capable of switching 400-V 60-A DC loads. (Capable of interrupting 600 A at 300 VDC max.) • The switching section and driving section are gas-injected and hermetically sealed, allowing these compact relays to interrupt high-capacity loads.
G7L - Omron
omronfs.omron.com• Miniature size for maximum switching power, particularly for inductive loads. • Flame-resistance materials (UL94V-0-qualifying) used for all insulation material. • Quick-connect, screw, and PCB terminals, and DIN track mounting available. • Conforms to UL, CSA, TUV and meets IEC950. • Safety design with contact gap of 3 mm.
G6S - Omron
omronfs.omron.comElectrical 100,000 operations min. for AC (at 1,800 operations/h with rated load) 100,000 operations min. for DC (at 1,200 operations/h with rated load) Failure rate (P level) (reference value) *3 10 μA at 10 m VDC Ambient operating temperature-40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation)
G2R - Omron
omronfs.omron.com3 G2R PCB Power Relay G 2 R Quick-connect Terminal (#187) Full-wave Rectifier For Ultrasonically Cleanable Note: When ordering, add the rated coil voltage to the model number. Example: G2R-1A-T AC12 However, the notation of the coil voltage on the produc t case as well as on the packing will be marked as @@ VAC.
Related documents
Pneumatic Valves and Motion Control - Ingersoll Rand
ingersollrand.jpPneumatic Valves |3 Accessories Accessory Valves • 100 Series - 3-way N.C., miniature limit valves. • 200 Series - 3-way limit valve-ideal for sensing devices such as cylinders, slides and gates. • 400 Series - Heavy duty 3-way limit valves, 4 actuator arms available. • 460 Series - 3-way palm button valves. • The 200, 400 and 460 are multipurpose valves, plumb N.O.,
Miniature Signal Relays EC2/EE2
content.kemet.comMiniature Signal Relays – EC2/EE2 Pin Configurations Bottom view Safety Standards and Ratings Certification Body Mark Specification File Number Rating UL UL Recognized (UL508)1 E73266 30 VDC, 2 A (resistive) 110 VDC, 0.3 A (resistive) 125 VAC, 0.5 A (resistive) CSA CSA Certified (CSA 22.2 #14) LR46266 1 Spacing: UL114, UL478 Certification Body
Motor Protection Solutions - Rockwell Automation
literature.rockwellautomation.comrelay allow users to view this diagnostic information using the following methods: • Logix add-on profile • Embedded web browser • FactoryTalk® View ... miniature contactors and 104-K miniature reversing contactors. Offers basic motor protection at an economic price. Functions
G4A - Omron
omronfs.omron.comMiniature Single-pole Relay with 80A Surge Current and 20A Switching Current • Capable of Switching Motor Load of 80-A Surge Current and 20A Switching/Cut-off Current † Miniature, relay with high switching power and long endurance. † Creepage distance conforms to UL and CSA standards.
CHAPTER – 3 ELECTRICAL PROTECTION SYSTEM
www.iitr.ac.inMiniature circuit breakers are replacing fuses. A circuit breaker is an interrupting device designed for normal switching functions as well as for fault interruption. Circuit breakers offer considerable flexibility and are available in variety of voltage, current, ... Protective relay must be isolated from the high-voltage system but require ...
1 Form A/1 Form C/2 Form A/2 Form C, 5 A/10 A, Power relays
www3.panasonic.bizMiniature/slim: 12.8 mm(W) × 28.6 mm(L) × 20 mm(H) Standard type (5 A) and high capacity type (10 A) are available PC board sockets are available ... Therefore, please use the relay within ±5% of rated coil voltage. • ‘Initial’ means the condition of products at the time of delivery. Rated coil voltage Operate voltage*1