G6E - Omron
12 VDC 12 VDC 12 VDC 12 VDC 12 VDC ... Vibration resistance Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) ... (Isolation) *1, *3 G6E-134P-US (Average value (initial))
Download G6E - Omron
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
CSM PCB Con CN J 1 3 - omronfs.omron.com
omronfs.omron.comA-20 最新の商品情報・便利な情報は www.fa.omron.co.jp/ コネクタ 共通の注意事項 コネクタ 共通の注意事項 挿抜作業について ・通電中の挿抜作業時および抜去後に、コネクタの接点 …
CSM XM2 XM3 AC DS J 1 8 - omronfs.omron.com
omronfs.omron.com2 最新の商品情報・便利な情報は www.fa.omron.co.jp/ XM2/XM3 Dサブコネクタ X M 2 / X M 3 注1. 1個のコネクタに固定具は2個必要です。 注2. 形XM3K/Lには取付できません。
Solid State Pressure Sensors D8M - omronfs.omron.com
omronfs.omron.comCompact D8M solid state pressure sensors provide reliable detection for gas and air inflow for burner controls in water heaters, furnaces and other gas-fired devices.
G5V-2 - omronfs.omron.com
omronfs.omron.com2 G5V-2 Low Signal Relay G 5 V-2 Ratings Coil Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C.
G6B - Omron
omronfs.omron.com3 G6B PCB Power Relay G 6 B Models for Ultrasonically Cleanable Note: When ordering, add the rated coil voltage to the model number. Example: G6B-1114P-US DC5 However, the notation of the coil voltage on the produc t case as well as on the packing will be marked as @@ VDC.
Solid State Relays Common Precautions
omronfs.omron.com2.Inductive Noise Do not wire power lines alongside the input lines. Inductive noise may cause the SSR to malfunction. If inductive noise is imposed on the input terminals of the SSR, use the following cables according to the type of inductive noise, and reduce the noise level to less than the must release voltage of the SSR.
DC Power Relays
omronfs.omron.comHigh-voltage, High-current Loads • A compact relay (73 x 36 x 67.2 mm (L x W x H)) capable of switching 400-V 60-A DC loads. (Capable of interrupting 600 A at 300 VDC max.) • The switching section and driving section are gas-injected and hermetically sealed, allowing these compact relays to interrupt high-capacity loads.
G7L - Omron
omronfs.omron.com• Miniature size for maximum switching power, particularly for inductive loads. • Flame-resistance materials (UL94V-0-qualifying) used for all insulation material. • Quick-connect, screw, and PCB terminals, and DIN track mounting available. • Conforms to UL, CSA, TUV and meets IEC950. • Safety design with contact gap of 3 mm.
G2RL - Omron
omronfs.omron.comTest conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the relays to check the number of malfunctions. Requirement: None malfuction 100 m/s2 Sample: G2RL-24 12 VDC Number of relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing
G6S - Omron
omronfs.omron.comElectrical 100,000 operations min. for AC (at 1,800 operations/h with rated load) 100,000 operations min. for DC (at 1,200 operations/h with rated load) Failure rate (P level) (reference value) *3 10 μA at 10 m VDC Ambient operating temperature-40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation)
Related documents
PowerBeam ac Datasheet - Ubiquiti
dl.ubnt.comVibration Test IEC 68-2-6 Temperature Shock Test IEC 68-2-14 UV Test IEC 68-2-5 at 40° C (104° F), Equivalent: ETS 300 019-1-4 Wind-Driven Rain Test ETS 300 019-1-4, Equivalent: MIL-STD-810 G Method 506.5 PBE-5AC-300 Output Power: 25 dBm TX Power Specifications RX Power Specifications
CCG Series Datasheet - TDK
product.tdk.comin ambient temperature of -40 to 100oC and has an input to output isolation of 1,500Vdc. Six sided shielding reduces radiated and conducted EMI. • Supports Dual 12/24V or 24/48V System Voltages • Less Board Area Needed • Easier System Compliance • More Useable Power Model Selector Input Output Maximum Input Current at Efficiency (%)
Liquiphant M FTL50(H), FTL51(H)
portal.endress.comLiquiphant M FTL50(H), FTL51(H) 4 Endress+Hauser Application Point level detection Maximum or minimum detection in tanks or pipes containing all kinds of liquids, including use in hazardous areas, food and pharmaceuticals. L00-FTL5xxxx-11-05-xx-xx-000 Function and system design
NI 9221 Datasheet - National Instruments
www.ni.com8 AI, ±60 V, 12 Bit, 800 kS/s Aggregate • DSUB, screw-terminal, or spring-terminal connectivity • 250 Vrms, CAT II, channel-to-earth isolation (screw and spring terminal); 60 VDC , CAT I, channel-to-earth isolation (DSUB) • -40 °C to 70 °C operating range, 5 g vibration, 50 g shock The NI 9221 is an analog input module for CompactDAQ ...