Table 1: Glasroc F FireCase fixings. Board thickness (mm) Min. fixing length Board-to-board fixing Board-to-metal fixing 15 Glasroc F FireCase Screws 40mm ... Gyproc plasterboard lining. Refer to construction detail 16 on page 3.14. – For further information please please refer to Technical Support on .
Download Identification
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Gyproc Moisture Resistant - british-gypsum.com
www.british-gypsum.comGyproc Moisture Resistant Product Data Sheet Introduction Suitable as a base for tiling in wet use areas. Also used for external soffits in sheltered positions.
C05. S02. P02 – P30 ShaftWall - british-gypsum.com
www.british-gypsum.comC05 Introduction Specialist partitions Specialist partitions This section details specialist lightweight systems where high-security, curved, fire or …
C05. S05. P02 – P05 GypWall secure - british …
www.british-gypsum.comC05. S05. P02 – P05 GypWall secure Including C05. S01. P02 Specialist partitions introduction This section includes updated information, added since it was first
Robustness SYSTEM DESIGN PRINCIPLES
www.british-gypsum.comImportantly for design, the greatest rate of strength loss is in the range of 400°C to 600°C. Using fire design codes such as the Structural Eurocodes EC3-1.2 and EC4-1.2 (designated BS EN 1993-1-2 and BS EN 1994-1-2), the load on the structure at the time of the fire can be calculated by treating it as an accidental limit state.
Gyproc SoundBloc 12 - british-gypsum.com
www.british-gypsum.comEither cut the board with a plasterboard saw, or score the front face paper with a sharp knife, snap it over a straightedge, then cut the back face paper. Cut holes for things like socket boxes using a utility saw. Fixing Fix the board with the decorative side facing outwards to receive finishes. Install fixings at least 13mm from cut
GypCeiling MF - british-gypsum.com
www.british-gypsum.comRefer to construction detail 7, relating to double layer 12.5mm Gyproc SoundBloc linings. With concrete floors the high mass of the construction means that high levels of acoustic performance can be achieved when the GypCeiling MF ceiling is suspended by conventional means, i.e. Gypframe MF8 Strap Hangers or Gypframe FEA1 Steel Angle.
Product Data Sheet - british-gypsum.com
www.british-gypsum.comadditives for extra fire protection. Where to use. Use it in partitions, ceilings and steel encasement . systems to achieve the fire performance required in domestic separating walls, corridors, garages and steel encasements. Certifications. Environmental Product Declaration (EPD) available Click here. Product information. Composition
Related documents
NBS - Reference Specification - SE Controls
www.secontrols.comK10 PLASTERBOARD DRY LININGS FOR WALLS, PARTITIONS AND CEILINGS 132 K11 RIGID SHEET FLOORING, SHEATHING, DECKING, SARKING, LININGS AND CASINGS 136 ... Z20 FIXINGS AND ADHESIVES 278 Z21 MORTARS 280 Z22 SEALANTS 282 Page 4 of 282. ... Fixing of services: Submit typical details of locations, types and methods of fixing of services …
EzyBrace Systems - GIB
www.gib.co.nzplasterboard linings. — Enhanced thermal performance. — ®Allows internal walls lined with GIB plasterboard on both sides and fastened off as per the standard fixing requirements of the current GIB® Site Guide to contribute bracing resistance. — …
The Posi-Joist Technical Handbook
irp-cdn.multiscreensite.comceiling plasterboard. The responsibility for specification of the plasterboard and its fixings rests with the Building Designer. Posi-Joist floors with a variety of build-ups have been independently tested to both BS and EN Standards and those Posi-Joist floors providing 30 minutes fire resistance are listed in the tables below. Fire Resistance
Technical Manual - CSR Hebel
hebel.com.au• For proprietary fixings by others, contact the manufacturer or visit the appropriate website. Fixing selector Determine the grade of fixing (Selection table) to suit your application and select a fixing (Types of Fixing Table). Use ‘Design Tables’ to check the adequacy of the fixing and contact the manufacturer for confirmation.
WHITE BOOK - CasoLine MF - Rossendale
www.rossendale.gov.ukBoard fixings for Gyptone boards should be at 230mm centres across board-ends and through the field of the board. Board fixings for Rigitone boards should be at 150mm centres at perimeters and 230mm through the field of the board. A special procedure is used for fixing and jointing Rigitone boards.