MRH - SOFIMA HYD
D5 D4 D2 90° H1 6 R 30 D1 H4 D6 H6 H5 H3 H2 D3 E3 E2 E1 D5 D4 D2 90° H1 6 R 30 D1 H4 D6 H6 H5 H3 H2 D3 E3 E2 E1 Indicator port Type 250: port not available Type D1 D2 D3 D4 D5 D6 E1 E2 E3 H1 H2 H3 H4 H5 H6 R
Download MRH - SOFIMA HYD
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
RFM - SOFIMA HYD
www.sofima-hyd.com§ = 2” 1/2. Further information on request. Type D1 D2 H1 min D2 max D3 D4 D5 H2 H3 H4 H5 E T Weight Kg RFM 004 RFM 008 RFM 009 RFM 011 RFM 012 RFM 015 RFM 02 0
RFA - SOFIMA HYD
www.sofima-hyd.comRFA 1 MPa (10 bar) Port sizes: 1/2” ÷ 1” Flow rates: 30 ÷ 140 l/min TECHNICAL DATA Max. working pressure: 1 MPa (10 bar) Fatigue test: 0 ÷ 1 MPa (10 bar) / …
Air Filters - SOFIMA HYD
www.sofima-hyd.comType l/min Spare Cartridge Fig.3 Fig.4 Fig.5 35 µm 35 µm 20 µm 164 164 187 2,20 2,10 4,30 92 92 125 125 2” 2” 2” GAS GAS GAS GAS GAS GAS 1” 1/4 1” 1/2 2” 0,55
CONTAMINATION CONTROL IN HyDRAULIC …
www.sofima-hyd.comFILTERS AND FILTER MEDIA All the hydraulic systems have an initial solid contamination, tending to increase during operation due to component wear,
Control, Hydraulic, Filter, Contamination, Contamination control in hydraulic
AMF - SOFIMA HYD
www.sofima-hyd.comh2 h1 h3 h5 h4 e4 e4 d1 d2 e1 e3 d3 d1 e2 (*) e5 e d c a b spin-on elements dimensional layout type cca 151 cca 152 cca 301 cca 302 95 …
RFC - SOFIMA HYD
www.sofima-hyd.comCLOGGING INDICATORS 64,5 30 48 35 M20 x 1,5 G R 2 3 1+ 4-N.C. N.O. C Setting 130 kPa (1,3 bar) NBR FKM 7B EB Differential ELECTRICAL indicator …
MSZ - SOFIMA HYD
www.sofima-hyd.comMSZ Port sizes: 1/2” ÷ 3” Flow rates: 15 ÷ 550 l/min TECHNICAL DATA Bypass valve: 30 kPa (0,3 bar) ± 10% on request Filter element collapse pressure:
SPM - SOFIMA HYDRAULIC FILTERS
www.sofima-hyd.comType ∆ p SPM 301 FT FC FD FV CD CV RD MV 25 27 39 62 80 110 100 112 55 62 73 110 130 130 130 130 70 81 95 130 130 130 130 130 Filter Media Type ∆ p SPM 302 FT FC FD FV CD CV RD MV 34 38
LFM - SOFIMA HYD
www.sofima-hyd.comlfm 010 050 070 120 cle 180 rd mv cd cv ms mn rd = 10µ mv = 25µ cd = 10µ cv = 25µ ms = 60µ mn = 125µ rd = 10µ rv = 25µ cd = 10µ cv = 25µ ms = 60µ mn = 125µ
MDM - SOFIMA HYD
www.sofima-hyd.comCLOGGING INDICATORS 2 3 1 64,5 30 48 35 M20 x 1,5 NBR FKM Differential ELECTRICAL indicators Recommended tightening torque 90 Nm SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively
Related documents
Brief Industrial Profile of RANCHI District - DCMSME
dcmsme.gov.in- 1 - Brief Industrial Profile of RANCHI District . 1. General Characteristics of the District: 1.1: Location & Geographical Area: Ranchi is the capital of Jharkhand State.
bxrt - Harco Enterprises
www.harcosupply.comPails & Utensils bxrt @ 675 The Parkway Peterborough, ON K9J 7K2 1-800-361-5361 705-743-5361 Fax: 705-743-4312 www.harcosupply.com sales@harco.on.ca • Scoops & Dippers
dupont nomex paper type 410
www.nomex-klebeband.deTemperature has a minor effect on dielectric strength and dielectric constant, as shown in Figure 1. Variations in frequency up to 104 Hz have essentially no effect on the dielectric constant of DuPont™ Nomex® paper ® Type 410.
CHESTER DISTRICT, SC EQUITY INDEX
www.piedmont-historical-society.org134 Plaintiff(s) Defendant(s) Class of Paper No. Years Hicklin, Jason Sr Mrs. E R Gladden et al Bill 456 1860-1869 Hicklin, Jason Sr W M Dye et al " 459 1868-1869 Hunsucker,aco J b et al A Hunsucker et al " 462 1867- " Hogan Michael , et al DB Rothrods " 512 1867-1874 Hogan Michael , Admr William Thompson " 526 !869-1874
Paper, District, Index, Equity, Chester, Chester district, Sc equity index
Oil Analysis Tables - RSA Reliability and Maintenance ...
www.rsareliability.comMaintenance Excellence Rolly Angeles RSA 2003 Oil Analysis Important Tables ISO 4406 CODE From To 26 320,000 640,000 25 160,000 320,000 24 80,000 160,000 23 40,000 80,000
RFM - SOFIMA HYD
www.sofima-hyd.comtype rfm 004 rfm 008 rfm 009 rfm 011 rfm 012 rfm 015 rfm 020 rfm 025 rfm 030 rfm 040 rfm 050 rfm 055 rfm 060 rfm 070 rfm 08 0 rfm 100 rfm 101 rfm 125
Oregon Medicaid Fee-for-Service PA Criteria
www.oregon.govOregon Medicaid PA Criteria 6 June 1, 2017 Introduction A bout this guide The Oregon Medicaid Pharmaceutical Services PA Criteria is designed to assist the following