Example: bachelor of science

3-Way Pilot Valves - AMOT

3-Way Pilot ValvesKey features and benefitsl Suitable for use on many types of fluid: l Clean air l Natural gas l LP gases l Petroleum base lubricants l Hydraulic oils l Many other fluidsl Balanced force design, pressure can be applied to any port - simplifies system designl Can be panel or bracket mounted - simple, flexible and low cost installationl Uses the AMOT patented Tad Pole seal - provides lower friction and longer cycle life than conventional O-ringsTypical applications Developed for use in manual and automatic control systems:l Hydraulic fluid controll Actuator controll Pneumatic panel systemsl Safety control systems Models 4057 and 4457 Aluminum and stainless steel versions 4057D Valve (Aluminum)Type 4457A Valve (Stainless Steel)Overview AMOT Models 4057 and 4457 3-Way Valves have been developed for use in manual and automatic hydraulic or pneumatic control systems. They offer versatility in operating requirements and allowable pressure limits. For a 1/4 size control valve, they offer exceptional flow capacity.

page 2 3-Way Pilot Valves - Models 4057/4457 Datasheet_4057_4457_pilot_valve_0212_Rev2 The 3-way pilot valves feature modular construction and incorporate a sliding spool.

Tags:

  7450, Valves, Pilots, 3 way pilot valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 3-Way Pilot Valves - AMOT

1 3-Way Pilot ValvesKey features and benefitsl Suitable for use on many types of fluid: l Clean air l Natural gas l LP gases l Petroleum base lubricants l Hydraulic oils l Many other fluidsl Balanced force design, pressure can be applied to any port - simplifies system designl Can be panel or bracket mounted - simple, flexible and low cost installationl Uses the AMOT patented Tad Pole seal - provides lower friction and longer cycle life than conventional O-ringsTypical applications Developed for use in manual and automatic control systems:l Hydraulic fluid controll Actuator controll Pneumatic panel systemsl Safety control systems Models 4057 and 4457 Aluminum and stainless steel versions 4057D Valve (Aluminum)Type 4457A Valve (Stainless Steel)Overview AMOT Models 4057 and 4457 3-Way Valves have been developed for use in manual and automatic hydraulic or pneumatic control systems. They offer versatility in operating requirements and allowable pressure limits. For a 1/4 size control valve, they offer exceptional flow capacity.

2 Datasheet_4057_4457_pilot_valve_0212_Rev 2page 2 3-Way Pilot Valves - Models 4057/4457 Datasheet_4057_4457_pilot_valve_0212_Rev 2 The 3-Way Pilot Valves feature modular construction and incorporate a sliding spool. The standard spool has a small center dead spot position and no valve port overlap. With the spool fully to the left (rest position), Port 2 is open to Port 3 and Port 1 is closed. With the spool moved to the right (actuated position), OperationPort 2 is open to Port 1 and Port 3 is closed. The Valves are available with a variety of manual and pressure operators and with manual, pressure or spring returns. See the valve types table below for the standard variations which are TypesManual operated kg (5 lbs) force requiredType CAType CFDouble Pilot operated bar (10 psi) pressure requiredType CBManual pull Spring return kg (15 lbs) force requiredManual or pressure operated Manual return bar (10 psi) pressure or kg (6 lbs) force requiredManual or pressure operated spring return, bar (26 psi) pressure or kg (16 lbs) force requiredPressure operated, spring return.

3 Bar (26 psi)Double Pilot operated spring return in one direction. bar (10 psi) and bar (26 psi) requiredManual latch or pressure operated, spring return when released. bar (26 psi) pressure pressure operated spring return. Adjustable from to bar (5 to 15 psi) Manual latch or pressure operated, spring return when released. bar (13 psi) pressure requiredType SBType CTType CPType CSType CGType CDType C1 Type CEType C2 Mechanical limit valve Machine actuated Spring return kg (15 lbs) force requiredNormally open Pressure operated Internal pressure returnpage 3 3-Way Pilot Valves - Models 4057/4457 Datasheet_4057_4457_pilot_valve_0212_Rev 2 Type CA: Manual operated kg (5 lbs) force requiredType CB: Manual pull spring return kg (15 lbs) force requiredSpecification 4057 4457 Body material Anodised aluminum Stainless steel Standard spool and internal materials Anodised aluminum Anodised aluminumStandard seal materials Viton Viton Maximum temperature 120 C (250 F) 120 C (250 F)Flow coefficient Cv = Cv = pressure at Ports 1, 2 or 3 bar (125 psi) bar (125 psi) Maximum pressure at Ports A or B bar (150 psi) bar (150 psi)Maximum pressure at bar (125 psi) Not available Port C (types CT & SB only) Net weight to kg ( to 2 lbs) to kg ( to lbs) Type CD: Manual or pressure operated manual return, bar (10 psi) pressure or kg (6 lbs) force requiredType CE: Manual or pressure operated spring return, bar (26 psi) pressure or kg (16 lbs) force required Type CG.

4 Pressure operated, spring return, bar (26 psi) pressure (1 1/8 ) mm (1 1/8 ) mm (1 1/32 ) mm (11/32 ) mm (13/4 ) 54mm (21/8 )27mm (11/16 ) (3/4 ) (1 1/2 ) (9/32 ) (4 1/8 ) (1 ) (3/8 ) (1 3/8 ) (13/16 ) (13/16 ) (1/2 ) (1/2 ) (1 ) (5/8 ) Panel opening (7/8 ) (6 ) (2 7/8 ) page 4 3-Way Pilot Valves - Models 4057/4457 Datasheet_4057_4457_pilot_valve_0212_Rev 2 Type CP: Manual latch or pressure operated, spring return when released. bar (26 psi) pressure required. Type CT: Adjustable pressure operated spring return. Adjustable from to bar (5 to 15 psi). Dimensions continuedType SB: Manual latch or pressure operated, spring return when released bar (13 psi) Type CF: Double Pilot operated, bar (10 psi) pressure C2: Double Pilot operated, spring return in one direction, bar (10 psi) and bar (26 psi) pressure (2 7/8 )157mm (6 ) 210mm (8 1/4 ) (9/16 ) 173mm (6 13/16 ) 22mm (7/8 ) 65mm (2 9/16 ) (7 1/2 ) 73mm (2 7/8 ) (9/16 ) (7 5/8 ) (2 9/16 )140mm) (5 1/2 ) (1 1/8 ) (1 1/8 ) ) (1 ) (13/4 )54mm (21/8 ) 27mm (11/16 ) (3/4 ) (1 1/2 ) (9/32 ) (3 ) ) (1 ) (13/4 )page 5 3-Way Pilot Valves - Models 4057/4457 Datasheet_4057_4457_pilot_valve_0212_Rev 2 How to orderUse the table below to select the unique specification of your 4057 3-Way Pilot ValveExample Code4057D019F1-AABasic ModelBasic Model4057 DAnodized AluminiumOperator, Finish and Thread - Gulf-Proofed NPTO perator, Finish and Thread - Gulf Proofed Anodised Aluminium NPT 019 FCA - Manual operated - kg / 5 lbs force required020 FCB - Manual pull spring return kg / 15 lbs force required022 HCD - Manual or pressure operated manual return, 10 psi ( bar)

5 Pressure or kg / 6 lbs force required023 HCE - Manual or pressure operated spring return, bar / 26 psi pressure or kg / 6 lbs force required025 HCP - Manual latch or pressure operated, spring return when released. bar / 26 psi pressure required027 KSB - Manual latch or pressure operated, spring return when released bar / 26 psi029 KCT - Adjustable pressure operated spring return. Adjustable from to bar / 5 to 15 psi 031 HCG - Pressure operated, spring return, bar / 26 psi pressure required032 JCF - Double Pilot operated, bar / 10 psi pressure required035JC2 - Double Pilot operated, spring return in one direction, bar / 10 psi and bar / 26 psi pressure requiredStandard Spool - Valve typeSpool 1 Standard centre dead spotCA, CB, CD, CE, CP, CT, CG, CF, C22 Valve port overlap5 Standard centre dead spotSB6 Valve port overlapCustomer Special CodeCustomer Special Requirements-AAStandard Product-**Customer Special CodeUse the table below to select the unique specification of your 4457 3-Way Pilot ValveExample Code4457A001F1-AABasic ModelBasic Model4457 AStainless SteelOperator, Finish and Thread - Stainless Steel NPTO perator, Finish and Thread - Stainless Steel NPT001 FCA - Manual operated - kg / 5 lbs force required002 FCB - Manual pull spring return kg / 15 lbs force required004 HCD - Manual or pressure operated manual return.

6 Bar / 10 psi pressure or kg / 6 lbs force required005 HCE - Manual or pressure operated spring return, bar / 26 psi pressure or kg / 16 lbs force required007 HCP - Manual latch or pressure operated, spring return when released. bar / 26 psi pressure required013 HCG - Pressure operated, spring return, bar / 26 psi pressure required014 JCF - Double Pilot operated, bar / 10 psi pressure requiredSpool - Valve TypeSpool 1 Standard center dead spot2 Valve port overlapCustomer Special CodeCustomer Special Requirements-AAStandard Product-**Customer Special Codepage 6 3-Way Pilot Valves - Models 4057/4457 Datasheet_4057_4457_pilot_valve_0212_Rev 2 For all types except CT & SB (Viton) Kit 9113X001 Ref no.:Qty DescriptionPart ring, Viton7896L00242 Seal ring, Viton7898L002 Bracket Mounting or Panel Mounting. A satin chrome nut, Part Number: 3496L001 is available as an option, and it substitutes for the standard nut to improve the appearance for the front of a panel KitsFor Types CT & SB (Viton) Kit 9128X001 Ref no.

7 :Qty DescriptionPart ring, Viton7896L002471 Diaphragm, Viton2254L002481 Thread seal7898L002(May contain extra parts when used with some Valves ).Types CT & SBRed Knob: Part Number 681L001 is available for types CA, CB, CD or CE as a substitute for the standard black knob. 342 req d4 req d4 req d34748 Europe and AfricaAMOTW estern WayBury St EdmundsSuffolk, IP33 3 SZEnglandTel +44 (0) 1284 762222 Fax +44 (0) 1284 760256 Email Controls GmbHRondenbarg 2522525 HamburgGermanyTel +49 (0) 40 8537 1298 Fax +49 (0) 40 8537 1331 Email Russia#34 Shabolovka StreetBuilding 2 Moscow 115419 RussiaTel: +7 495 617 12 93 Fax: +7 495 913 97 65 AmericasAMOT USA 8824 Fallbrook DrHouston TX 77064 USATel: +1 (281) 940 1800 Fax +1 (713) 559 9419 Email Asia and AustralasiaAMOT ShanghaiRm 4102 - 4104 United Plaza1468 Nanjing Road WestShanghai 200040 ChinaTel +86 (0) 21 6279 7700 Fax +86 (0) 21 5237 8560 Email Singapore10 Eunos Road 8 #12-06 Singapore Post CentreSingapore 408600 Tel +65 6408 6265 Fax +65 6293 3307 Email


Related search queries