40ADC UPS Module DR-UPS40

SPECIFICATIONMODELMTBFDIMENSIONNOTEPACKI NG C (as available on ) C C DC UPS ModuleDR-UPS40 DC INPUT /DC BUSBATTERYINPUT /OUTPUTOTHERSENVIRONMENTDR-UPS40DC voltage (Typ.) CURRENTVOLTAGE RANGE (Typ.)CURRENT RANGE CHARGE CURRENT (Typ.) BATTERY (Typ.)RELAY CONTACT RATING (max.)DC BUS OKBATTERY FAIL DISCHARGEWORKING HUMIDITYSTORAGE TEMP., HUMIDITYVIBRATION24 ~ 29V40A21 ~ 29V0 ~ 40A2A4 / 7 / 12AH / 24V30 VDC, 1 ARelay contact : Short when DC voltage between 21~29V( 3%), relay contacts LED(Green) : DC BUS OK : light ; DC BUS fail : darkLED(Red) : Battery over-discharge warning or battery broken : light ; Battery OK : darkShort when battery voltage falls below ( 3%) or battery failure is observed through the battery test function, relay contactsRelay contact : Short when battery in discharge condition, relay contacts LED(Yellow):light : Battery discharging dark : Battery is not discharging or discharging current< ~ +70 C20 ~ 90% RH -20 ~ +85 C, 10 ~ 95% RHComponent : 10 ~ 500Hz, 2G , 60min.

40adc ups module dr-ups40 ’ = dc input / dc bus battery input / output others environment dr-ups40 dc voltage (typ.) note.5 rated current voltage range (typ.) current range charge current (typ.) note.4 external battery (typ.) relay contact rating (max.) dc bus ok battery fail note.2 battery discharge working temp. working humidity storage ...

Tags:

  Module, Voltage

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 40ADC UPS Module DR-UPS40

1 SPECIFICATIONMODELMTBFDIMENSIONNOTEPACKI NG C (as available on ) C C DC UPS ModuleDR-UPS40 DC INPUT /DC BUSBATTERYINPUT /OUTPUTOTHERSENVIRONMENTDR-UPS40DC voltage (Typ.) CURRENTVOLTAGE RANGE (Typ.)CURRENT RANGE CHARGE CURRENT (Typ.) BATTERY (Typ.)RELAY CONTACT RATING (max.)DC BUS OKBATTERY FAIL DISCHARGEWORKING HUMIDITYSTORAGE TEMP., HUMIDITYVIBRATION24 ~ 29V40A21 ~ 29V0 ~ 40A2A4 / 7 / 12AH / 24V30 VDC, 1 ARelay contact : Short when DC voltage between 21~29V( 3%), relay contacts LED(Green) : DC BUS OK : light ; DC BUS fail : darkLED(Red) : Battery over-discharge warning or battery broken : light ; Battery OK : darkShort when battery voltage falls below ( 3%) or battery failure is observed through the battery test function, relay contactsRelay contact : Short when battery in discharge condition, relay contacts LED(Yellow):light : Battery discharging dark : Battery is not discharging or discharging current< ~ +70 C20 ~ 90% RH -20 ~ +85 C, 10 ~ 95% RHComponent : 10 ~ 500Hz, 2G , 60min.

2 Each X, Y, Z axes ; Mounting : Compliance to * *100mm (W*H*D) ; 20pcs/12 &EMC(Note 3) WITHSTAND VOLTAGEISOLATION RESISTANCET erminal-Chassis :>100M Ohms / 500 VDC / 25 C/ 70% RHTerminal-Chassis , Relay Contacts-Terminal to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EACTPTC020 Compliance to EN61000-4-2,3,4,5,6,8, heavy industry level, criteria ABS EN/,11, EACTPTC020 EMC IMMUNITYEMC EMISSIONFile Name: DR-UPS40 -SPEC 2022-03-18AS/NZS62368-1 TPTC004 User s Manual hrs min. Telcordia SR-332 (Bellcore) ; hrs min. MIL-HDBK-217F (25 C)Case Unit:mmMechanical SpecificationTerminal Pin No. Assignment (TB1)Terminal Pin No. Assignment (TB2)Pin INPUT +DC INPUT -BATTERY INPUT -BATTERY INPUT +DC OK 1DC OK 2 BAT FAIL 1 BAT FAIL 2 BAT DISC 1 BAT DISC 2 ADMISSIBLE DIN-RAIL:TS35 OR TS35/1535 Block +24V25Ax2 BATTERYDC OKBAT FAILBAT DISCHARGEINPUT+AMBIENT TEMPERATURE ( C)LOAD (%)-2001020304550607020406080100(VERTICA L)Derating DC UPS ModuleFile Name: DR-UPS40 -SPEC up connection for AC redundancy Module (DR-RDN20) to back up AC interruption or failure of PSUS uggested ApplicationDCBATDR-UPS40 PSU24V24V/40A ++--+++---DCBATDR-UPS40DR-RDN2024 VPSUALoadBattery +++---+++-----40A DC UPS ModulePSUB+-File Name: DR-UPS40 -SPEC 2022-03-18