Example: dental hygienist

CardaxFT Universal Reader Interface - uvel.com

CardaxFTUniversalReader InterfaceThe CardaxFT Universal ReaderInterface provides an interfacefor connecting Cardax readers andthird party readers to theCardaxFT Universal Reader InterfaceConnectivity Diagrams: Cardax ReadersCardax entry and exit readers connected to the CardaxFTUniversal Reader Interface for the access control of one Cardax entry readers (with push button exits) connected to theCardaxFT Universal Reader Interface for the access control of two Commsfrom CardaxFTController orprevious deviceDoor 1 Strike OutputDoor 1 Position StatusDoor 1 Lock StatusSpare Output Relay4 Spare Inputs forIntruder Alarm UseRS485 Comms tonext DC 15%Door 1 CardaxEntry ReaderDoor 1 CardaxExit ReaderCardaxCommsDoor 1 Strike OutputDoor 1 Position StatusDoor 1 Lock StatusDoor 1 Push Button Exit (or Intruder Alarm Input Optional)

CardaxFT Universal Reader Interface The CardaxFT Universal Reader Interface provides an interface for connecting Cardax readers and third party readers to the

Tags:

  Interface, Universal, Reader, Cardaxft universal reader interface, Cardaxft

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of CardaxFT Universal Reader Interface - uvel.com

1 CardaxFTUniversalReader InterfaceThe CardaxFT Universal ReaderInterface provides an interfacefor connecting Cardax readers andthird party readers to theCardaxFT Universal Reader InterfaceConnectivity Diagrams: Cardax ReadersCardax entry and exit readers connected to the CardaxFTUniversal Reader Interface for the access control of one Cardax entry readers (with push button exits) connected to theCardaxFT Universal Reader Interface for the access control of two Commsfrom CardaxFTController orprevious deviceDoor 1 Strike OutputDoor 1 Position StatusDoor 1 Lock StatusSpare Output Relay4 Spare Inputs forIntruder Alarm UseRS485 Comms tonext DC 15%Door 1 CardaxEntry ReaderDoor 1 CardaxExit ReaderCardaxCommsDoor 1 Strike OutputDoor 1 Position StatusDoor 1 Lock StatusDoor 1 Push Button Exit (or Intruder Alarm Input Optional)

2 Door 1 CardaxEntry ReaderDoor 2 CardaxEntry ReaderCardaxCommsDoor 2 Strike OutputDoor 2 Position StatusDoor 2 Lock StatusDoor 2 Push Button Exit (or Intruder Alarm Input Optional)RS485 Commsfrom CardaxFTController orprevious deviceRS485 Comms tonext DC 15% Universal Reader InterfaceCardaxFTThe CardaxFT Universal Reader Interface extendsthe CardaxFT system by integrating Cardax doorreaders and third party CardaxFT Universal Reader Interfaceprovides an Interface for connectingCardax door readers, and selectedWiegand format and other third partyreaders, to the CardaxFT system. A thirdparty keypad can also be CardaxFT Controller is the fieldcontroller in the CardaxFT system,supporting 16 field devices. The Cardaxdoor readers and third party readersattached to the CardaxFT UniversalReader Interface do not count amongstthese 16 field Cardax ReadersConnecting to the CardaxFT Controllerover RS485, the CardaxFT UniversalReader Interface is capable ofsupporting two Cardax readers using4-core CardaxFT Universal Reader Interfacesupports the following Cardax doorreaders.

3 Cardax Prox (125, Mifare and TIRIS Series) Cardax Prox Plus (125, Mifare and TIRIS Series) Cardax Prox LR (TIRIS Series) Cardax Swipe (Magstripe) Cardax Swipe PlusIntegrating Third Party ReadersUsing a 6-core cable connection, theCardaxFT Universal Reader Interface iscapable of supporting two Wiegandformat readers and a large number ofWiegand formats. In addition to thereaders, it can also support one thirdparty keypad using 4 x 3 matrix Inputs and OutputsMaking no high level decisions, theCardaxFT Universal Reader Interfacemonitors the state of the balancedinputs and switches the output relaysas instructed by the CardaxFT six balanced inputs on the CardaxFTUniversal Reader Interface are designedto be used as follows: inputs for monitoring"Door Open" state inputs for monitoring"Door Locked" state auxiliary inputs for push button exitcontrolThe inputs can also be used as normalinput connections for other Diagram.

4 Wiegand format ReadersTwo Wiegand format readers and one third party keypadconnected to the CardaxFT Universal Reader Interface forthe access control of one features of the CardaxFT Universal Reader InterfaceRS485 Commsfrom CardaxFTController orprevious deviceRS485 Comms tonext deviceDoor 1 Strike OutputDoor 1 Position StatusDoor 1 Lock StatusSpare Output Relay4 Spare Inputs forIntruder Alarm DC 15%Door 1 Wiegand FormatEntry ReaderDoor 1 Wiegand FormatExit ReaderWiegandCommsExternalKeypadCardaxFT UniversalReaderInterface5 V4k7 InputplugTamperswitchR14k7 PIR DetectorRelayR24k70 V5 V4k7 InputplugR24k7 GNDR14k7 Alarm SensorReader 2 ConnectionRelayOutputConnectorsRelaysBal ancedInputsPower andComms InRun/DiagnosticIndicatorFront OpticalTamper Detector(door open) Reader 1 ConnectionKeypadConnectionFusedPower OutRear Optical TamperDetector (Cabinetremoved) on reverseside of PCBO utputPlug12 VDoor StrikeSirenNormally OpenNormally ClosedCommonRelay Output to door strike connectionOutputPlug12 VNormally OpenNormally ClosedCommonRelay Output to siren connectionRRInput to sensor connection with tamperInput to sensor connection without tamperCardaxFT Cabinet (with 2 Universal Reader Interfaces)The inputs on the CardaxFT UniversalReader Interface are 4-state balancedinputs.

5 The four states monitored are: Open Closed Short Circuit (Tamper) Open Circuit (Tamper)Two 4K7 Ohm resistors must beconnected to monitored inputs (asillustrated in the Input to sensorconnection diagrams). The tworesistors (R1 and R2) allow a tamperswitch as well as a sensor output tobe wired to each inputs on the CardaxFT UniversalReader Interface can be used tomonitor: Access controlled doors Passive Infra-Red detectors (PIRs) Uncontrolled doors Equipment alarms Any other devices that provide aclean contactOutputsThe CardaxFT Universal ReaderInterface contains 2 relay relay outputs can be used in thefollowing ways: To unlock access controlled doors(as illustrated in the Relay Outputto door strike connection diagram) As alarm outputs, to activatesirens (as illustrated in the RelayOutput to siren connection diagram) As logic activated outputs, to switch on air conditioning As time activated outputs, to switch on lightingCardaxFT CabinetThe CardaxFT Cabinet is a secureenclosure for the CardaxFT UniversalReader Interface .

6 It provides cost-effective housing and includes manyfeatures designed to makeinstallation and servicing design of the CardaxFT Cabinetenables several Cabinets to beinstalled side by side, neatly fittingtogether. Each Cabinet has a lockabledoor that can be installed, on site, tohinge from any the Printed Circuit Board (PCB)is installed in the CardaxFT Cabinet,optical tamper protection is front optical tamper detector willsense when the Cabinet door isopened. The rear optical tamperdetector will sense if the Cabinetis being removed from the from a strongpolycarbonate/ABS plastic alloy, theCardaxFT Cabinet has a UL94 flamerating of a Mounting Plate, the Cabinetcan house one or two CardaxFTUniversal Reader Interface PCBs,or one CardaxFT Universal ReaderInterface PCB and one CardaxFTStrike Controller PCB (aninput/output device designedto control two doors).

7 The CardaxFT Universal ReaderInterface must be mounted in aCardaxFT Cabinet following thedirections in the installationinstructions to comply withinternational emission standardssuch as C-Tick, FCC and SPECIFICATIONS CardaxFT Universal Reader InterfacePower Supply V DC 15%Current 300 mANumber of PortsRS4851 Reader ports for Cardax and third party readers2 Keypad port (third party)1 CommunicationsTo CardaxFT ControllerRS485 at Kbits per secondTo Cardax readersCardax proprietaryTo third party readersWiegand formatCable SpecificationsCommunications to: CardaxFT ControllerTwo wire Cat 5 (or better) Data CableCardax readers4-core cableThird party readers6-core cableThird party keypad4 x 3 matrix wiringPowerDependent upon distance from power supplyand current required by readersMax Cable LengthsFrom CardaxFT Controller500 mTo Cardax readers200 mTo third party readers 100 mInputs / OutputsInputs (4-state balanced)6 Relay Outputs 2 Electrical Outputs SpecificationsRelays are capable of switching the following loads.

8 3 Amps at 24 V DC/AC resistive load1 Amp at 24V DC/AC inductive loadSupported ID TechnologiesCardax Magnetic StripeIndala (27 bit)Cardax ProximityMotorola Secure (32 bit)Cardax Smart CardWiegand 26/8 bitDeister (64 bit)Wiegand 26/12 bitHughes proximity (36 bit)Please discuss your ID technology requirements with your nearest Cardax officeHousingCardaxFT CabinetHeight280 mmWidth280 mmDepth94 mmWeight (nominal)One PCB and Cabinet1662 gramsTwo PCBs and Cabinet1824 gramsEnvironmental DataTemperature range-10 to +55 CFire ResistanceFlame rating of CabinetUL94 HBCompliance StandardsThe CardaxFT Universal Reader Interface complies with C-Tick. Compliancewith other international standards will be proven during 2001 contact Cardax for the latest list of CardaxFT PCBs must be mounted in CardaxFT Cabinets following the directions in the installation instructions to comply with international 2001 6J8106 04/01 Cardax (International) Limited 2001.

9 All rights (International) LimitedKahikatea DrivePrivate Bag 3026 HamiltonNew ZealandPhone+64-7-838 9851 Fax +64-7-838 9801 Email Offices are located in:AustraliaChinaNew ZealandSouth AfricaUnited KingdomUnited States of AmericaWhilst every effort has been made to ensure accuracy, neither Cardax (International) Limited nor any employee of the company, shall be liable on any ground whatsoeverto any party in respect of decisions or actions they may make as a result of using this accordance with the Cardax policy of continuing development, design and specifications are subject to change without and manufactured by Cardax (International) Limited, an ISO 9001 certificated is a registered trademark of Cardax (International) (International) Limited is a subsidiary of Gallagher Group pending.