CDU, CDX - EBARA Pumps Americas Corp
Standard Pump Division 300 (t) 803 327 5005 • (f) 803 327 5097 • [email protected] rev. 09/18 Item No. Specifications Selection Performance Pump Sectional View Chart Curve Dimensions CDU70/0-1/2HP ...
Tags:
Performance, Specification, Time, Pumps, Selection, Item no, Specifications selection performance pump
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Submersible Slurry Pumps - Ebara Pump
www.pumpsebara.comSubmersible Slurry Pumps. Ebara Submersible Slurry Pump ENZX Operating, Installation and Maintenance ... Please be sure that the actual flow and head is the same as the performance curve. If the actual flow is ... conduct an air pressure test for motor and mech. seal chamber. There should be no leakage within 5 minutes under 29 PSI.
User, Seal, Pumps, Submersible, Submersible slurry pumps, Slurry
EBARA Submersible Stainless Steel Pumps DWU, …
www.pumpsebara.comEBARA Fluid Handling www.pumpsebara.com 1-131 (803) 327-5005 • (803) 327-5097 (fax) rev. 09/08 EBARA Submersible Stainless Steel Pumps DWU, DWXU – Dominator Selection Chart Model DWX(A)U DWXF(A)U
Pumps, Steel, Stainless, Submersible, Dominator, Ebara submersible stainless steel pumps dwu, Ebara
EBARA Submersible Sewage Pumps DLU
www.pumpsebara.comEBARA Submersible Sewage Pumps DLU Specifications Project: Model: Chk’d: Date: Model DLU S ecificaˇi ˘ S a a O a Size 2, 3, 4 inch Range of HP 1 to 2 HP Three Phase
Pumps, Submersible, Sewage, Ebara, Ebara submersible sewage pumps dlu
EBARA Submersible Stainless Steel Pumps …
www.pumpsebara.comEBARA Submersible Stainless Steel Pumps Optima/EPD Contents Project: Model: Chk’d: Date: EBARAFluid Handling www.pumpsebara.com 1-100 (803) 327-5005 • (803) 327-5097 (fa) rev. 03/12
Pumps, Steel, Stainless, Submersible, Optima, Ebara, Ebara submersible stainless steel pumps, Ebara submersible stainless steel pumps optima
EPD, Optima IOM, instruction and operation …
www.pumpsebara.comEBARA Fluid Handling www.pumpsebara.com 5 (t) 803 327-5005 † (f) 803 327-5097 rev. 12/07 EBARA Submersible Sump/Drainage Pumps EPD / Optima Important Safeguards To reduce risk of injury, alwaysfollow these instructions and safety precautions when using this pump and to maintain warranty.
EBARA Submersible Wastewater Pumps DMLEU
www.pumpsebara.comEBARA Submersible Wastewater Pumps DMLEU Contents Project: Model: Chk’d: Date: EBARAFluid Handling www.pumpsebara.com 2-136 (803) 327-5005 • (803) 327-5097 (fax) rev. 01/13
Wastewater, Pumps, Submersible, Ebara, Ebara submersible wastewater pumps dmleu, Dmleu
EBARA Submersible Sewage Pumps DLFU Contents
www.pumpsebara.comEBARA Submersible Sewage Pumps DLFU Contents Project: Model: Chk’d: Date: Model DLFU 50DLFU61.5 80DLFU61.5 80DLMFU61.5 80DLFU62.2 80DLMFU62.2 80DLFU63.7 80DLMFU63.7
Pumps, Content, Submersible, Sewage, Ufld, Ebara, Ebara submersible sewage pumps dlfu contents
Sc Pa - Ebara Pump
www.pumpsebara.comEBARA Self Priming Trash Pump EFQT/EFQU Model Designation Project: Model: Chk’d: Date:
2CDXU-2CDU, Technical Section, rev. 0116 - Ebara …
www.pumpsebara.comModel 2CDX Model Designation 2CDX/2CDU EBARA Stainless Steel Two-Stage Centrifugal Pumps EBARAFluid Handling www.pumpsebara.com 601 (t) 803 327-5005 • (f) 803 327-5097 rev. 12/03
Section, Technical, 6110, Ebara, Technical section, 2cdxu 2cdu, 2cdxu, 2cdu, 0116 ebara, 2cdu ebara
Model EVMU /EVMUG / EVMUL - EBARA Fluid …
www.pumpsebara.comAlways check to make sure pump was not damaged in shipment before accepting delivery. If damage is evident, a claim should be filed with the carrier at that time.
Related documents
0904 3U 3UB - EBARA Pumps Americas Corp
www.pumpsebara.comItem No. Specifications Selection Performance Pump Sectional View Chart Curve Dimensions 3U-32-125-3HP
Performance, Specification, Time, Pumps, Selection, Item no, Specifications selection performance pump, 3u 3ub
Agilent InfinityLab LC Series 1260 Infinity II ...
www.agilent.comPhysical Specifications 37 Performance Specifications 41 pmu 9Pe4h tgn i3Us Magnets 50 Turn on/off 51 Status Indicators 53 Best Practices 54 Leak and Waste Handling 57 Hints for Successful Use of the Pump 59 Setting up the Pump with the G4208A Instant Pilot 60 Setting up the Pump with the Instrument Control Interface 61 Solvent Information 71
Performance, Series, 2016, Specification, Pumps, Agilent, Infinity, Performance specifications, Infinitylab, Agilent infinitylab lc series 1260 infinity
Agilent 1290 Infinity Binary Pump User Manual
www.agilent.comThe Binary pump is designed for highest performance, GLP compliance and easy maintenance. It includes the following features: † Seal wash for continued high lifetime of pump seals for buffer applications. † Solvent selection valve for method flexibility. † Jet Weaver for optimum mixing performance with a minimum of delay volume.
Manual, Performance, User, Pumps, Selection, 2019, Binary, Agilent, Infinity, Agilent 1290 infinity binary pump user manual
Hydraulic Considerations in Pumping System Design
cdn.ymaws.comn •Energy dissipated due to friction and turbulence during pump operation •Major Losses (Friction Losses) • Due to friction between pumped water and inner surface of piping • H f = 3.02 L D-1.167 (V/C h)1.85 (Hazen-Williams Formula) where: • L is length of pipe (feet) • D is diameter of pipe (square feet) • V is mean velocity (fps) • C h is Hazen-Williams friction coefficient ...
System, Design, Pumps, Hydraulic, Considerations, Pumping, Hydraulic considerations in pumping system design
KASHIYAMA IND., LTD.
www.idealvac.comThe output signal (pin No. 5-13) is no-voltage relay contact outputs. Apply a voltage of 24 V DC, 0.1A or less on the equipment side. When condensable gas such as water vapor is pumped, please keep it running for about 1 hour opening the inlet port. There is a possibility of pump failure arising from corrosion or other factors