CEAG Products Ex-Solutions LED Lighting
The LED system design and certification allow the use in the proved Ex e technology of the ... LED 800A = 1360 M8, 14 deep M25 x 1.5 LED 400A = 400 LED 800A = 700 21 Hexagon A/F 13 M8, 14 deep ... C90 l/cd/klm 90 75 60 45 30 15 0 15 30 45 60 75 90 100 200 300 400 500 C 0 C90 l/cd/klm 90 75 60 45 30 15 0 75 90 100 200 300 400 500.
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Safe. Reliable. Effi cient. - CROUSE-HINDS
www.crouse-hinds.deCustom Type I, III and V optics for better output, zero maintenance and reduced energy consumption Harsh & heavy industrial A Modular design - This contractor-friendly design is ideal for both retrofit and new construction applications.
Ex-plugs and receptacles 63 A 4/5-pole up to 690 V 1
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BVS17.0062X Marking accd. to IECEx Ex db eb [ia Ga] IIC/IIB T5 Gb / Ex tb IIIC T80°C Db Permissible ambient temperature -20 °C up to +55 °C (IIC)-40°C up to +40 °C (IIB) Rated voltage 690 V (AC) Rated current 63 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 accd. EN 60947-3 U e ...
Receptacles, Plugs, Conformity, Iecex, Of conformity iecex, Ex plugs and receptacles 63 a
EX-PLUGS AND RECEPTACLES - CROUSE-HINDS
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BKI 04.0002 Marking accd. to IECEx Ex ed [ia] IIC T6/T5 Permissible ambient temperature -20°C up to +40°C 1) Rated voltage up to 400 V, (3-pole) / 690 V, (4-pole) / 500 V, (5-pole) AC Rated current 16 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 U e 250 V / I e 16 A (3-pole) accd.
Ex-e/i Cable Glands - CROUSE-HINDS
www.crouse-hinds.de2.3.4 EATON www.crouse-hinds.de 3.1 Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and 22 1 - according to EN 60079-0: 2012 Conform with latest stand-ards Cable glands with metric screw-in threads are now standard and had replace the PG cable glands that were formally used. The CEAG plastic cable glands are in accordance with
Global Reference Guide on the Marking of Electrical ...
www.crouse-hinds.deDirective 2014/34/EU (previously 94/9/EG) (ATEX) Marking according to IEC/CENELEC/CSA standard 60079-0 Typical marking of electrical equipment for use in explosive dust atmospheres (EU/ATEX/IECEx): Electrical types of protection for explosive atmospheres due to fl ammable gases, vapours and mists Type Protec-tion level Type of protection Group ...
CEAG ProductsMain Catalogue Part 2: Chapter 2
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BVS 16.0024 Marking accd. to IECEx Ex e IIC T5/T6 Gb Ex tb IIIC T80°C Db Permissible ambient temperature –20 °C to +40 °C / -55 C to +55 °C (option) Rated voltage 690 V / 550 V1) Terminal cross section max. 3 x 4 mm ...
Certificate, Conformity, Iecex, Iecex certificate of conformity iecex
Industrial Plugs & Receptacles - CROUSE-HINDS
www.crouse-hinds.deRated current 63 A 63 A 63 A 63 A 63 A Cable entry 1 x M50 Ø 22 - 35 mm, 1 x M50 thread plug plastic 1x M50 Ø 22 - 35 mm, 1 x M50 thread plug plastic Ø 19 - 34 mm Ø 19 - 34 mm Connecting terminals 2 x 4 – 25 mm 2 with switch 2 x 4 – 35 mm without switch 1 x 4 – 16 mm / with pin cable lug 2) 1 x 35 mm2 1 x 2.5 – 35 mm2 1 x 2.5 – 35 mm2
Switch, Industrial, Receptacles, Trade, Plugs, Industrial plugs amp receptacles
Ex-Linear light fittings for fluorescent lamps
www.crouse-hinds.dein hazardous areas The eLLK 92 linear luminaire se-ries for fluorescent lamps com-bines the latest lighting technol-ogy with the requirements of a harsh and hazardous envi-ronment. This luminaire series is available in various sizes as a ceiling mounted light fitting (eLLK) and as a pole-mounted light fitting (eLLM). Long-term safety
Linear light fitting series with new LED module for ...
www.crouse-hinds.deeLLM 92 LED 800A 1/3-1K 1 x 3 – – 1 x M25, Plastic 1 2269 505 101 1 2269 504 101 eLLK 92 LED 400 V-CG-S 2) eLLK 92 LED 400 V-CG-S 2/6-2K 2 x 6 – x 2 x M25, Plastic 2 x M25 1 2265 517 103 1 2265 516 103 eLLK 92 LED 400 V-CG-S 2/6-2M 1) 2 x 6 – x 4 x M20, Metal thread 2 x M25 1 2265 517 111 1 2265 516 111
Champ VMVL LED luminaires - 3,000 to 11,000 lumens
www.crouse-hinds.deWall 4.50 2.04 Angled stanchion 3.50 1.59 Straight stanchion 4.50 2.04 Weights: Model lbs. kg. VMVL-3 to VMVL-7 19.00 8.62 VMVL-9 & VMVL-11 19.20 8.70 VMVL-3 to VMVL-11 40°C 55°C 65°C Class I, Division 2 T5 T5 T4A Class II, Division 1 T5 T4A T4A Simultaneous rating Class I, Division 1 & 2 T3C T3A T3A Class I, Zone 2 AEx nA nR; Ex nA nR T5 T5 ...
Related documents
System No. W-L-1360 WL 1360 - hiltiman.com
hiltiman.comSystem No. W-L-1360 SECTION A-A WL 1360 Page: 1 of 2 1. Wall Assembly -- The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300, U400 or V400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following
PART 25 AIRWORTHINESS STANDARDS: TRANSPORT …
www.engineerstoolkit.comCONTROL S URFACE AND S YSTEM L OADS 25.391 Control surface loads: general. 25.393 Loads parallel to hinge line. 25.395 Control system. 25.397 Control system loads. 25.399 Dual control system. 25.405 Secondary control system. 25.407 Trim tab effects. 25.409 Tabs. 25.415 Ground gust conditions. 25.427 Unsymmetrical loads. 25.445 Auxiliary ...
Spec sheet for Cat 259B Series 3 Compact Track Loader …
www.holtcat.comDisplacement 3.3 L 201 in3 Stroke 120 mm 4.7 in Bore 94 mm 3.7 in Weights* Operating Weight (320 mm/12.6 in tracks) 4052 kg 8,934 lb Operating Weight (400 mm/15.7 in tracks) 4185 kg 9,227 lb Power Train Travel Speed (Forward or Reverse) One Speed 9.5 km/h 5.9 mph Two Speed 13.6 km/h 8.5 mph Hydraulic System Hydraulic Flow – Standard:
Fluid System Products - John Guest
www.johnguest.compart no. tube tube mounting bag box od od hole dia. qty qty pp121208w 3/8 - 1/4 0.83 10 150 two way divider part no. tube bag box od qty qty pp2312w 3/8 10 150 female adapter nptf thread part no. tube thread bag box od nptf qty qty pp450821w 1/4 x 1/8 10 400 pp450822w 1/4 x 1/4 10 200
Ventilation Fundamentals - Solutions for Air
www.solutionsforair.comt a y l e v i s u l c x e e l b a l i a v a s t c u d o r p n o t y a D l l A All Dayton products available exclusively at 4 Reading Performance Charts The most important part of selecting a fan is the ability to read the performance charts. Most of the performance charts in the catalog are similar and are read in the same manner.
EZ Dock Product Guide & Price List
ezdocktexas.comCoupler set (bulk pack) w/hardware 301100 Coupler set (2 pair) w/hardware 301200 Coupler set (3 pair) w/hardware 301300 A view of the bottom and inside of an EZ Dock section reveals ßotation chambers and an extra-heavy wall thickness that creates tremendous structural integrity. The patented ßotation