Example: air traffic controller

Common mode - KEMET

1 KEMET Electronics Corporation Box 5928 Greenville, SC 29606 864-963-6300 LF0016_SU9V/9H 3/28/2017 One world. One KEMETB enefits Wide variety of sizes and specifications Inductances up to 18 mH Rated Currents up to A DC Resistances as low as OverviewThe KEMET SU Coils, SU 9V/9H Type AC line filters are offered in a wide variety of sizes and Consumer Electronics Common mode chokeAC Line FiltersSU Coils, SU 9V/9H TypePart Number SystemSU9V-R02140 SeriesCore Size (mm)Core OrientationCore TypeRated Current (A)Minimum Inductance (mH)SU9 = = VerticalH- = HorizontalBlank = StandardR = High permeability0x = A ( , 02 = A)xx = A ( , 10 = A)xx0 = xx mH ( , 140 = 14 mH)0xx = mH ( , 020 = mH)00x = mH ( , 005 = mH)AC Line Filters26 Rated voltage: 250 VAC Withstanding voltage: AC 2400V (2 sec between lines) Insulation resistance: at 500 VDC, more than 100M (between lines) Thermal class.

© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com LF0016_SU9V/9H • 3/28/2017 3 AC Line Filters SU Coils ...

Tags:

  Dome, Common, Kemet, Common mode kemet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Common mode - KEMET

1 1 KEMET Electronics Corporation Box 5928 Greenville, SC 29606 864-963-6300 LF0016_SU9V/9H 3/28/2017 One world. One KEMETB enefits Wide variety of sizes and specifications Inductances up to 18 mH Rated Currents up to A DC Resistances as low as OverviewThe KEMET SU Coils, SU 9V/9H Type AC line filters are offered in a wide variety of sizes and Consumer Electronics Common mode chokeAC Line FiltersSU Coils, SU 9V/9H TypePart Number SystemSU9V-R02140 SeriesCore Size (mm)Core OrientationCore TypeRated Current (A)Minimum Inductance (mH)SU9 = = VerticalH- = HorizontalBlank = StandardR = High permeability0x = A ( , 02 = A)xx = A ( , 10 = A)xx0 = xx mH ( , 140 = 14 mH)0xx = mH ( , 020 = mH)00x = mH ( , 005 = mH)AC Line Filters26 Rated voltage: 250 VAC Withstanding voltage: AC 2400V (2 sec between lines) Insulation resistance: at 500 VDC, more than 100M (between lines) Thermal class.

2 E (120 C) Operating temperature range ( C): 25 to T (T=120 temperature rise) Inductance measurement condition: 1kHz, 1V, KC530 Shape and DimensionsModelDC resistance(G/line) (K) (mH) (g)Ratedcurrent(A)Numbering SystemSU 9 V - 01 100/ 0 1 2 3 4 Series Core size Core Type(V : vertical type, H : horizontal type) Core Type(R : high permeability core) Current rating(01 shows ) Inductance (100 shows 10mH)SU CoilsSU 9V/9H Type[RoHS Compliant]SU CoilsSU 9V/9H Type[RoHS Compliant]SU9 01180R 02140R 03090R 05034R 07017R 10008 Marking#SU9V#SU9H mode2 KEMET Electronics Corporation Box 5928 Greenville, SC 29606 864-963-6300 LF0016_SU9V/9H 3/28/2017AC Line Filters SU Coils, SU 9V/9H TypeDimensions Millimeters SU9V Minimum17 ComplianceAll KEMET AC Line Filters are RoHS CompliantTable 1 Ratings & Part Number Reference(1) To complete KEMET part number, insert V for vertical core type or H for horizontal core NumberRated Current AC (A)Inductance (mH) MinimumDC Resistance/Line ( ) MaximumTemperature Rise (K) MaximumMarkingWeight (g) ApproximateSU9(1) (1) (1)- (1)- (1) (1) U9(1) - R (1)- (1)- (1)

3 - (1) (1) KEMET Electronics Corporation Box 5928 Greenville, SC 29606 864-963-6300 LF0016_SU9V/9H 3/28/2017AC Line Filters SU Coils, SU 9V/9H TypeSpecificationsFrequency CharacteristicsNotes on UseShelf Life Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before Condition Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. Avoid storage in atmosphere containing toxic gases or acid ( , sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. Avoid storage near strong magnetic field, as such condition may magnetize the 9V/9 HRated Voltage250 VACW ithstanding Voltage2,400 VAC (2 seconds, between lines)Insulation Resistance> 100 M at 500 VDC (between lines)Thermal ClassE (120 C)Operating Temperature Range 25 C to T (T = 120 temperature rise)Inductance Measurement Condition1 kHz, 1 V, KC530AC Line Filters27 Frequency characteristicR0118R0214R0309R0701R0503R 10001M100K10K1K100101 Impedance ( ) Frequency (Hz)1K10K100K1M10M 30M3613613613611361363 613 6133613 611M100K10K1K100101 Impedance ( ) Frequency (Hz)1K10K100K1M10M 30M3613613613611361363 613 6133613 61R01180R02140R03090R01180R02140R03090R0 7017R05034R10008R07017R05034R100081M100K 10K1K100101 Impedance ( ) Frequency (Hz)

4 1K10K100K1M10M 30M33613613613611361363 613 613 613 610701005020100050701005020100051M100K10 K1K100101 Impedance ( ) Frequency (Hz)1K10K100K1M10M 30M33613613613611361363 613 613 613 61020800305001100 Common mode4 KEMET Electronics Corporation Box 5928 Greenville, SC 29606 864-963-6300 LF0016_SU9V/9H 3/28/2017AC Line Filters SU Coils, SU 9V/9H TypeKEMET Electronic Corporation Sales Offi cesFor a complete list of our global sales offi ces, please visit product specifi cations, statements, information and data (collectively, the Information ) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or of suitability for certain applications are based on KEMET Electronics Corporation s ( KEMET ) knowledge of typical operating conditions for such applications, but are not intended to constitute and KEMET specifi cally disclaims any warranty concerning suitability for a specifi c customer application or use.

5 The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property all product related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required.

6 KEMET is a registered trademark of KEMET Electronics Corporation.