Example: marketing

CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)

CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) _____ _____ _____ _____ _____ _____ _____ SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Manual 12/2014 A5E33591411-AB Preface Documentation guide 1 Product overview 2 Wiring 3 Interrupts, error messages, diagnostics and system alarms 4 Technical specifications 5 Dimension drawing A Siemens AG Division Digital Factory Postfach 48 48 90026 N RNBERG GERMANY A5E33591411-AB 12/2014 Subject to change Copyright Siemens AG 2014. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property.

CPU 1512SP-1 PN sends and receives data from the connected IO devices within a PROFINET IO system. You can operate the CPU with a maximum of 128 connected IO devices, a maximum of 64 of which use IRT (Isochronous Realtime). I-device The "I-device" (intelligent IO device) functionality allows you to exchange data with an IO controller.

Tags:

  System, Profinet, Profinet io system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)

1 CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) _____ _____ _____ _____ _____ _____ _____ SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Manual 12/2014 A5E33591411-AB Preface Documentation guide 1 Product overview 2 Wiring 3 Interrupts, error messages, diagnostics and system alarms 4 Technical specifications 5 Dimension drawing A Siemens AG Division Digital Factory Postfach 48 48 90026 N RNBERG GERMANY A5E33591411-AB 12/2014 Subject to change Copyright Siemens AG 2014. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property.

2 The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken.

3 If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/ system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.

4 Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.

5 Trademarks All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) 4 Manual, 12/2014, A5E33591411-AB Preface Purpose of the documentation This manual supplements the ET 200SP distributed I/O system ( ) system manual as well as the function manuals.

6 All cross- system functions are described in the system manual and in the function manuals. The information provided in this manual and the system manual allows you to commission the CPU 1512SP-1 PN. Conventions STEP 7: In this documentation, "STEP 7" is used as a synonym for all versions of the configuration and programming software "STEP 7 (TIA Portal)". Please also observe the notes marked as follows: Note A note contains important information on the product described in the documentation, on the handling of the product or on the section of the documentation to which particular attention should be paid.

7 Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action ( cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.

8 Third-party products that may be in use should also be considered. You can find more information about industrial security on the Internet ( ). To stay informed about product updates as they occur, sign up for a product-specific newsletter. You can find more information on the Internet ( ). CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Manual, 12/2014, A5E33591411-AB 5 Table of contents Preface .. 4 1 Documentation guide .. 6 2 Product overview .. 8 Operating principle .. 8 Properties .. 9 Operating and display elements .. 12 Front view of the module with BusAdapter .. 12 Mode switch.

9 13 Functions .. 13 profinet IO .. 13 PROFI energy .. 14 PROFIBUS DP .. 15 Memory reset .. 16 Restoring the factory settings of the 18 3 Wiring .. 20 4 Interrupts, error messages, diagnostics and system alarms .. 25 Status and error display of the CPU .. 25 5 Technical specifications .. 28 A Dimension drawing .. 38 CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) 6 Manual, 12/2014, A5E33591411-AB Documentation guide 1 The documentation for the SIMATIC ET 200SP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require.

10 Basic information The system manual describes in detail the configuration, installation, wiring and commissioning of the SIMATIC ET 200SP. distributed I/O system . The STEP 7 online help supports you in the configuration and programming. Device information Product manuals contain a compact description of the module-specific information, such as properties, terminal diagrams, characteristics and technical specifications. General information The function manuals contain detailed descriptions on general topics regarding the SIMATIC ET 200SP distributed I/O system , diagnostics, communication, Web server, designing interference-free controllers.


Related search queries