DZ47LE C45LE Residual Current Circuit Breaker with Over ...

DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection Application DZ47LE C45LE RCBO is used for the protection against electrical leakage in the Circuit of 50Hz or 60Hz, rated voltage 1 phase 230V and 3 phase 400V, rated Current up to 63A. When somebody gets an electric shock or the Residual Current of the Circuit ex- ceeds the fixed value, the RCBO can cut off the power within the time of automati- cally to protect the personal safety and preventing the equipment from the fault resulted by the Residual Current . With this function, the RCBO can protect the Circuit against overload and short Circuit or can be used for the unfrequent switchover of the Circuit DZ47LE 1P+N under normal conditions.

DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection Application DZ47LE C45LE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage 1 phase 230V and 3 phase 400V, rated current up to 63A. When somebody gets an electric shock or the residual current of the circuit ex-

Tags:

  Current, Breaker, Circuit, Residual, Residual current, Dz47le c45le residual current circuit breaker, Dz47le, C45le

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DZ47LE C45LE Residual Current Circuit Breaker with Over ...

1 DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection Application DZ47LE C45LE RCBO is used for the protection against electrical leakage in the Circuit of 50Hz or 60Hz, rated voltage 1 phase 230V and 3 phase 400V, rated Current up to 63A. When somebody gets an electric shock or the Residual Current of the Circuit ex- ceeds the fixed value, the RCBO can cut off the power within the time of automati- cally to protect the personal safety and preventing the equipment from the fault resulted by the Residual Current . With this function, the RCBO can protect the Circuit against overload and short Circuit or can be used for the unfrequent switchover of the Circuit DZ47LE 1P+N under normal conditions.

2 It conforms to IEC61009 standard. Normal Operation and Mounting Requirement Circumstance temperature -5 C~+40 C, average temperature not exceeding 35 C. Altitude above sea level less than 2000m. Humidity not exceeding 50% at 40 C and not exceeding 90% at 25 C. Installation class II or III. Pollution class II. Installation method DIN Rail mounting type. The external magnetism shall not be more than 5 times of terrestrial one. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position. DZ47LE 3P. Specifications Number of Poles 1P+N, 2P, 3P, 3P+N, 4P. Rated Current (A) 6, 10, 16, 20, 25, 32, 40, 50, 63.

3 Rated operating Current (mA) 30, 100, 300, 500. Rated non operating (I N)(mA) n Rated voltage (V) 220/380. Tripping curve C, D. Type Electronic Wiring Diagram Single-Pole Double-Pole Triple-Pole Triple-Pole Four-Pole C45LE 1P+N. Double Line Double Line Triple Line Four Line Four Line C45N+DZ47L C45N+DZ47L C45N+DZ47L C45N+DZ47L C45N+DZ47L. C45N+C45L C45N+C45L C45N+C45L C45N+C45L C45N+C45L. 1/2 2/2 3/3 3/4 4/4. Operation Principle C45LE 3P. Tel:0086-577-88999052 Fax:0086-577-88999161 21. C65 NLE Residual Current Circuit Breaker with Over Current Protection Application C65 NLE RCBO is used for the protection against electrical leakage in the Circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated Current up to 60A.

4 When somebody gets an electric shock or the Residual Current of the Circuit exceeds the fixed value, the ELCB can cut off the power within the time of automatically to protect the personal safety and preventing the equipment from the fault resulted by the Residual Current . With this function, the ELCB can protect the Circuit against overload and short Circuit or can be used for the unfrequent switchover of the Circuit under normal conditions. C65 NLE 2P It conforms to IEC61009 standard. Specifications Number of Poles 1P+N, 2P, 3P, 3P+N, 4P. Rated voltage 240/415V. Rated Current 6A 10A 16A 20A 25A 32A 40A 50A 63A. Rated operating Current (mA) 30mA 100mA 300mA. Rated non-operating(I n) n Tripping Curve C, D.

5 C60 NLE Earth Leakage Circuit Breaker with Over C65 NLE 4P. Current Protection Specifications Number of Poles 2P. Rated Current (A) 10, 16, 20, 25, 32, 40. Rated Residual Operating Current (I n)(mA) 30, 100, 300. Rated Voltage (V) 230. Residual Current Off-time Short Circuit Capacity (Icu) (A) 4500. Dimensions 36 C60 NLE. Tel:0086-577-88999052 Fax:0086-577-88999161 22. DZ30LE(DPNLE) Earth Leakage Circuit Breaker with Over Cur- rent Protection Specifications Number of Poles 1P+N. Rated Current (A) 6, 10, 16, 20, 25, 32. Rated Residual Operating Current (I n)(mA) 30. Rated Residual Non-operation Current (I no)(mA) 15. Rated Voltage (V) 230. Residual Current Off-time Short Circuit Capacity (Icu) 4500A. DZ30LE Overload Trip Characteristic Testing Rated Limited Pre-engage Start Note Current (A) Voltage(V) Time Result Situation all t 1h non-trip cold state The Current rise steadily to a all t<1h trip heat state fixed value within 5s Open the supplementary all 1s<t<60s trip cole state switch, connect the power non-trip Open the supplementary 5In all t cold state switch, connect the power trip Open the supplementary 10In all t< cole state switch, connect the power Dimensions NC100LE 1P+N.

6 NC100LE Residual Current Circuit Breaker with Over Current Protection Application NC100LE RCBO is suitable for the Circuit of 50Hz, rated voltage 230/400V, and rated Current up to 100A. It has the earth leakage, overload & short Circuit protect function. It can also add over voltage protect function. It is mainly used in building illumination and electrical distribution system. Specifications Number of Poles 1P+N, 2P, 3P, 3P+N, 4P. Rated Current (A) 40, 50, 63, 80, 100. Rated Residual Operating Current (I n)(mA) 30, 50, 100, 200, 300. Rated Residual Non-operation Current (I no)(mA) n Rated Voltage (V) AC 230/400. Residual Current Off-time Short Circuit Capacity (Icu) 3000A. Endurance 4000. NC100LE 3P Tripping Curve C, D.

7 Protection Degree IP20. Tel:0086-577-88999052 Fax:0086-577-88999161 23. F360 Residual Current Circuit Breaker Application The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault Circuit immediately on the occasion of shock hazard or earth leakage of trunk. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for use in varieties of plants and enterprises, building con- struction 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC. pulse system. F360 2P(NEW). Specifications Number of Poles 2P, 4P. Rated Current (A) 16, 20, 25, 32, 40, 50, 63, 80. Rated Residual Operating Current (I n)(mA) 30, 100, 300.

8 Rated Residual Non-operation Current (I no)(mA) n AC 230/240. Rated Voltage (V). AC 400/415. Residual Operating Current Scope n~I n Residual Current Off-time Short Circuit Capacity (Icu) 3000A. F360 4P(NEW). Type A Type ,AC Type Protection Degree IP20. Operation Principle 1 3 1 3 5 7 N. 2 4 2 4 6 8 N. F360 2P. Overall And Mounting Dimensions (Unit: mm). 69. 68 35 70. 44 2 2. 2 2. 71. 46. 71. 46. F360 4P. Tel:0086-577-88999052 Fax:0086-577-88999161 24. ID Residual Current Circuit Breaker Application ID RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault Circuit immediately on the occasion of shock hazard or earth leakage of trunk. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage.

9 ID 2P The RCCB is mainly suitable for use in varieties of plants and enterprises, building con- struction 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC. pulse system. Specifications Number of Poles 1P+N, 3P+N. Rated Current (A) 16, 20, 25, 40, 50, 63. Rated Residual Operating Current (I n)(mA) 30, 100, 300, 500. ID 4P AC 230/240. Rated Voltage (V). AC 400/415. Residual Operating Current Scope n~I n Residual Current Off-time Short Circuit Capacity (Icu) 6000A. Endurance 4000. Protection Degree IP20. NFIN-2 2P. NFIN Residual Current Device Application The Residual Current Device NFIN is in conformity with the standard of IEC61008, VDE0664,CEE27 and BS4263. It can cut off the fault Circuit immediately on the occasion of shock hazard or earth leak- NFIN-2 4P.

10 Age of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage. NFIN RCD is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerce, guesthouses and families. It can be used in circuits of 1 phase 230V and 3 phase 400V 50/60Hz. Specifications Number of Poles 2P, 4P. NFIN-1 2P. Rated Current (A) 16, 20, 25, 32, 40, 50, 63, 80, 100. Rated Residual Operating Current (I n)(mA) 30, 100, 300, 500. Rated Residual Non-operation Current (I no)(mA) n Rated Voltage (V) AC 230/400. Residual Current Off-time Short Circuit Capacity (Icu) 3000A. Endurance 4000. NFIN-1 4P Protection Degree IP20. Tel:0086-577-88999052 Fax:0086-577-88999161 25. FIN Residual Current Device Application Residual Current Device(RCD) FIN is in conformity with the standard of IEC61008.