Example: biology

RESIDUAL CURRENT CIRCUIT BREAKERS LFN - OEZ

LFN RESIDUAL CURRENT CIRCUIT BREAKERS Minia RESIDUAL CURRENT CIRCUIT BREAKERS LFN. RESIDUAL CURRENT CIRCUIT BREAKERS with conditional short- Wide range of accessories - auxiliary and signal switch- CIRCUIT CURRENT 10 kA. es, undervoltage releases and shunt trips, intercon- For protection: necting busbars etc. against dangerous contact with live parts (I n 30 mA) Possibility of locking and sealing in off or on position. against dangerous contact with dead parts Possibility of interconnection with CIRCUIT BREAKERS LTP, against fire or short- CIRCUIT in reduced insulation LTS, LTN-UC by means of interconnecting busbars up capacity of electrical equipment. or down. Mounting/dismantling on/from U rails: The latches N-pole of RESIDUAL CURRENT CIRCUIT BREAKERS in switching enable very quick mounting and dismantling by on it closes before and in switching off it opens after hand, without any tool needed.

RESIDUAL CURRENT CIRCUIT BREAKERS LFN Residual current circuit breakers 2-pole, type A Residual current circuit breakers 4-pole, type A They react to both sine-wave residual current and pulsating direct residual current (type A). Standard type for common use in building and industrial installations up to 63 A, AC 230 V.

Tags:

  Current, Breaker, Circuit, Residual, Residual current, Residual current circuit breaker, Residual current circuit breakers lfn, Residual current circuit breakers lfn residual current circuit breakers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RESIDUAL CURRENT CIRCUIT BREAKERS LFN - OEZ

1 LFN RESIDUAL CURRENT CIRCUIT BREAKERS Minia RESIDUAL CURRENT CIRCUIT BREAKERS LFN. RESIDUAL CURRENT CIRCUIT BREAKERS with conditional short- Wide range of accessories - auxiliary and signal switch- CIRCUIT CURRENT 10 kA. es, undervoltage releases and shunt trips, intercon- For protection: necting busbars etc. against dangerous contact with live parts (I n 30 mA) Possibility of locking and sealing in off or on position. against dangerous contact with dead parts Possibility of interconnection with CIRCUIT BREAKERS LTP, against fire or short- CIRCUIT in reduced insulation LTS, LTN-UC by means of interconnecting busbars up capacity of electrical equipment. or down. Mounting/dismantling on/from U rails: The latches N-pole of RESIDUAL CURRENT CIRCUIT BREAKERS in switching enable very quick mounting and dismantling by on it closes before and in switching off it opens after hand, without any tool needed.

2 The other poles. Operating ambient temperature is for all designs RESIDUAL CURRENT CIRCUIT breaker are testing once per already from -25 C to +45 C. 6 months. Equipped with device status indicator. RESIDUAL CURRENT CIRCUIT BREAKERS 2-pole, type AC. They react to sine-wave RESIDUAL CURRENT (type AC). Surge CURRENT resistance 250 A (8/20 s). Standard type for common use in building and housing installations up to 40 A, AC 230 V. 10000 -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs]. 10 16 LFN-16-2-030AC OEZ:42408 2 1. 25 LFN-25-2-030AC OEZ:42409 2 1. 30 40 LFN-40-2-030AC OEZ:42410 2 1. 63 LFN-63-2-030AC OEZ:42411 2 1. 25 LFN-25-2-100AC OEZ:42412 2 1. 100 40 LFN-40-2-100AC OEZ:42413 2 1. LFN-25-2-100AC 63 LFN-63-2-100AC OEZ:42414 2 1. 25 LFN-25-2-300AC OEZ:42415 2 1. 300 40 LFN-40-2-300AC OEZ:42416 2 1. 63 LFN-63-2-300AC OEZ:42417 2 1. RESIDUAL CURRENT CIRCUIT BREAKERS 4-pole, type AC.

3 They react to sine-wave RESIDUAL CURRENT (type AC). Surge CURRENT resistance 250 A (8/20 s). Standard type for common use in building and housing installations up to 80 A, AC 230/400 V. 10000 -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs]. 25 LFN-25-4-030AC OEZ:42418 4 1. 40 LFN-40-4-030AC OEZ:42419 4 1. 30. 63 LFN-63-4-030AC OEZ:42420 4 1. 80 LFN-80-4-030AC OEZ:42421 4 1. 25 LFN-25-4-100AC OEZ:42422 4 1. 100 40 LFN-40-4-100AC OEZ:42423 4 1. LFN-40-4-030AC 63 LFN-63-4-100AC OEZ:42424 4 1. 25 LFN-25-4-300AC OEZ:42425 4 1. 40 LFN-40-4-300AC OEZ:42426 4 1. 300. 63 LFN-63-4-300AC OEZ:42427 4 1. 80 LFN-80-4-300AC OEZ:42428 4 1. 40 LFN-40-4-500AC OEZ:42429 4 1. 500. 63 LFN-63-4-500AC OEZ:42430 4 1. C7. Minia LFN RESIDUAL CURRENT CIRCUIT BREAKERS RESIDUAL CURRENT CIRCUIT BREAKERS LFN. RESIDUAL CURRENT CIRCUIT BREAKERS 2-pole, type A. They react to both sine-wave RESIDUAL CURRENT and Surge CURRENT resistance 1 kA (8/20 s).

4 Pulsating direct RESIDUAL CURRENT (type A). Standard type for common use in building and industrial installations up to 63 A, AC 230 V. 10000 -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs]. 10 16 LFN-16-2-010A OEZ:42441 2 1. 25 LFN-25-2-030A OEZ:42442 2 1. 30 40 LFN-40-2-030A OEZ:42443 2 1. 63 LFN-63-2-030A OEZ:42444 2 1. 25 LFN-25-2-100A OEZ:42445 2 1. LFN-25-2-030A 100 40 LFN-40-2-100A OEZ:42446 2 1. 63 LFN-63-2-100A OEZ:42447 2 1. 25 LFN-25-2-300A OEZ:42448 2 1. 300 40 LFN-40-2-300A OEZ:42449 2 1. 63 LFN-63-2-300A OEZ:42450 2 1. RESIDUAL CURRENT CIRCUIT BREAKERS 4-pole, type A. They react to both sine-wave RESIDUAL CURRENT and Surge CURRENT resistance 1 kA (8/20 s). pulsating direct RESIDUAL CURRENT (type A). Standard type for common use in building and industrial installations up to 80 A, AC 230/400 V. 10000 -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs].

5 25 LFN-25-4-030A OEZ:42451 4 1. 40 LFN-40-4-030A OEZ:42452 4 1. 30. 63 LFN-63-4-030A OEZ:42453 4 1. 80 LFN-80-4-030A OEZ:42454 4 1. 25 LFN-25-4-100A OEZ:42455 4 1. 100 40 LFN-40-4-100A OEZ:42456 4 1. LFN-40-4-030A 63 LFN-63-4-100A OEZ:42457 4 1. 25 LFN-25-4-300A OEZ:42458 4 1. 40 LFN-40-4-300A OEZ:42459 4 1. 300. 63 LFN-63-4-300A OEZ:42460 4 1. 80 LFN-80-4-300A OEZ:42461 4 1. 40 LFN-40-4-500A OEZ:42462 4 1. 500. 63 LFN-63-4-500A OEZ:42463 4 1. C8. LFN RESIDUAL CURRENT CIRCUIT BREAKERS Minia RESIDUAL CURRENT CIRCUIT BREAKERS LFN. RESIDUAL CURRENT CIRCUIT BREAKERS of G type Special RESIDUAL CURRENT CIRCUIT BREAKERS which reduce Operating ambient temperature is for all designs the number of undesirable releases. already from -25 C to +45 C. Conditional short- CIRCUIT CURRENT 10 kA. Equipped with status indicator. Release delay: 10 ms. Wide range of accessories auxiliary and signal For protection: switches, undervoltage releases and shunt trips, against dangerous contact with live parts (I n 30 mA) interconnecting busbars etc.

6 Against dangerous contact with dead parts Possibility of locking and sealing in off or on position. against fire or short- CIRCUIT in reduced insulation Possibility of interconnection with CIRCUIT BREAKERS LTP, capacity of electrical equipment (I n 100 mA). LTS, LTN-UC by means of interconnecting busbars up Mounting/dismantling on/from U rails: The latches or down. enable very quick mounting and dismantling by hand, without any tool needed. RESIDUAL CURRENT CIRCUIT BREAKERS 2-pole, type AC-G. They react to sine-wave alternating RESIDUAL CURRENT Surge CURRENT resistance 3 kA (8/20 s). (type AC). 10000 G -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs]. 25 LFN-25-2-030AC-G OEZ:42431 2 1. 30. 40 LFN-40-2-030AC-G OEZ:42432 2 1. LFN-25-2-100AC-G. LFN 25 2 100AC G. RESIDUAL CURRENT CIRCUIT BREAKERS 4-pole, type AC-G. They react to sine-wave alternating RESIDUAL CURRENT Surge CURRENT resistance 3 kA (8/20 s).

7 (type AC). 10000 G -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs]. 25 LFN-25-4-030AC-G OEZ:42433 4 1. 30 40 LFN-40-4-030AC-G OEZ:42434 4 1. 63 LFN-63-4-030AC-G OEZ:42435 4 1. 25 LFN-25-4-100AC-G OEZ:42437 4 1. 100 40 LFN-40-4-100AC-G OEZ:42438 4 1. 63 LFN-63-4-100AC-G OEZ:42439 4 1. LFN 40 4 030AC G. LFN-40-4-030AC-G. C9. Minia LFN RESIDUAL CURRENT CIRCUIT BREAKERS RESIDUAL CURRENT CIRCUIT BREAKERS LFN. RESIDUAL CURRENT CIRCUIT BREAKERS 2-pole, type A-G. They react to both sine-wave RESIDUAL CURRENT and Surge CURRENT resistance 3 kA (8/20 s). pulsating direct RESIDUAL CURRENT (type A). 10000 G -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs]. 25 LFN-25-2-030A-G OEZ:42464 2 1. 30. 40 LFN-40-2-030A-G OEZ:42465 2 1. LFN-25-2-030A-G. LFN 25 2 030A G. RESIDUAL CURRENT CIRCUIT BREAKERS 4-pole, type A-G. They react to both sine-wave RESIDUAL CURRENT and Surge CURRENT resistance 3 kA (8/20 s).

8 Pulsating direct RESIDUAL CURRENT (type A). 10000 G -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs]. 25 LFN-25-4-030A-G OEZ:42466 4 1. 40 LFN-40-4-030A-G OEZ:42467 4 1. 30. 63 LFN-63-4-030A-G OEZ:42468 4 1. 80 LFN-80-4-030A-G OEZ:42469 4 1. 25 LFN-25-4-100A-G OEZ:42470 4 1. 40 LFN-40-4-100A-G OEZ:42471 4 1. 100. LFN-40-4-030A-G. LFN 40 4 030A G 63 LFN-63-4-100A-G OEZ:42472 4 1. 80 LFN-80-4-100A-G OEZ:42473 4 1. C10. LFN RESIDUAL CURRENT CIRCUIT BREAKERS Minia RESIDUAL CURRENT CIRCUIT BREAKERS LFN. RESIDUAL CURRENT CIRCUIT BREAKERS of S type (selective). Special RESIDUAL CURRENT CIRCUIT BREAKERS which reduce Mounting/dismantling on/from U rails: The latches the number of undesirable releases and enable selec- enable very quick mounting and dismantling by tive switching of RESIDUAL CURRENT CIRCUIT BREAKERS . hand, without any tool needed. Conditional short- CIRCUIT CURRENT 10 kA.

9 Operating ambient temperature is for all designs Release delay: 40 ms. already from -25 C to +45 C. They react to both sine-wave RESIDUAL CURRENT and Equipped with device status indicator. pulsating direct RESIDUAL CURRENT (typ A). Wide range of accessories - auxiliary and signal Surge CURRENT resistance 5 kA (8/20 s). switches, undervoltage releases and shunt trips, For protection: interconnecting busbars etc. against dangerous contact with dead parts Possibility of locking and sealing in off or on position. against fire or short- CIRCUIT in reduced insulation Possibility of interconnection with CIRCUIT BREAKERS LTP, capacity of electrical equipment. LTS, LTN-UC by means of interconnecting busbars up or down. 10000 G -25. I n In Type Order Number Weight Package [mA] [A] code of modules [kg] [pcs]. 40 LFN-40-4-300A-S OEZ:42474 4 1. 300. 63 LFN-63-4-300A-S OEZ:42475 4 1. LFN-40-2-300A-S.

10 LFN 40 2 300A S. Accessories S2L Auxiliary and signal switches PS-LT, SS-LT page B36. Shunt trips SV-LT page B37. Undervoltage releases SP-LT page B37. Locking inserts OD-LT-VU02 page B39. Interconnecting busbars S2L, S2L+N, S3L, S3L+N, 1), S4L page B45. Terminal extension AS-50-S-AL01 page B47. 1). AS-50-S-AL01 For interconnection of the RESIDUAL CURRENT CIRCUIT breaker with a series of CIRCUIT BREAKERS where the series of CIRCUIT BREAKERS needs to start from N-pole of the RESIDUAL CURRENT CIRCUIT breaker . OD-LT-VP01. SV-LT PS-LT. C11. Minia LFN RESIDUAL CURRENT CIRCUIT BREAKERS RESIDUAL CURRENT CIRCUIT BREAKERS LFN. Specifications Type Standards EN 61008-1 EN 61008-1 EN 61008-1 EN 61008-1 EN 61008-1. EN 61008-2-1 EN 61008-2-1 EN 61008-2-1 EN 61008-2-1 EN 61008-2-1. EN 61543 EN 61543 EN 61543 EN 61543 EN 61543. Approval marks Number of poles 2 4 2 4 4. Type AC, A AC, A AC-G, A-G AC-G, A-G A-S.