Example: tourism industry

Ecotec Plus Open Vent Installation and Maintenance ...

EnInstallation and Maintenance instructionsecoTEC plusVU ..6/6-5 OVZ (H-GB) 0020238195_07 - and Maintenance instructions Ecotec plus 0020238195_07 Installation and safety information .. (directives, laws, standards).. of relevant standards for Great Britain 52 Guarantee and Customer 63 Technical 74 Notes on the documentation .. 95 Product Water Association .. number .. on the data the scope of the mounting the the front Removing/installing the side section.

ing(Qmin.) 4.5kW 4.5kW 5.0kW 6.1kW 7.2kW 7.1kW Maximumheatinput–do-mestichotwater(Qmax.) 18.4kW 18.4kW 25.7kW 30.6kW 35.7kW 35.7kW Minimumheatinput–do-mestichotwater(Qmin.) 4.5kW 4.5kW 5.1kW 6.1kW 7.2kW 7.1kW Technicaldata–Heating VU126/6-5 OVZ(H-GB) VU156/6-5 OVZ(H-GB) VU186/6-5 OVZ(H-GB) VU246/6-5 OVZ(H-GB) …

Tags:

  Vents

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Ecotec Plus Open Vent Installation and Maintenance ...

1 EnInstallation and Maintenance instructionsecoTEC plusVU ..6/6-5 OVZ (H-GB) 0020238195_07 - and Maintenance instructions Ecotec plus 0020238195_07 Installation and safety information .. (directives, laws, standards).. of relevant standards for Great Britain 52 Guarantee and Customer 63 Technical 74 Notes on the documentation .. 95 Product Water Association .. number .. on the data the scope of the mounting the the front Removing/installing the side section.

2 For the heating water supply in the open heatingsystem .. water supply in the sealed heatingsystem .. the heating flow and heatingreturn .. compliance with the local gas group .. the condensate discharge pipe .. Electrical Installation .. concept .. up the installer Monitor (status codes) .. out the initial and treating the heating water/fillingand supplementary water .. the condensate trap .. the heating Installation for the firsttime ("cold") .. on the product.

3 The Installation assistants .. the Installation assistants .. the heating Installation .. Checking the gas setting .. Thoroughly flushing the heating Installation ("hot").. Checking leak-tightness .. Checking the heating 3010 Adapting the unit to the Burner anti-cycling 3011 Handing over to the end 3112 Inspection and Maintenance .. Complete Service Interval Record section .. Using original Observing inspection and maintenanceintervals .. Checking the CO content.

4 Setting the CO content .. Removing the gas-air mixture Cleaning the heat Checking the burner .. Checking the ignition electrode .. Cleaning the condensate Installing the gas-air mixture Draining the product .. Completing inspection and Maintenance work .. 3413 Troubleshooting .. Rectifying faults .. Calling up the fault Deleting the fault Resetting parameters to factory Preparing the repair work .. Replacing defective Checking the product for leak-tightness.

5 3614 Decommissioning the 3615 Recycling and and Maintenance 37 BInstaller level 38 COverview of diagnostics 40 DStatus codes Overview .. 43 EOverview of fault codes .. 44 FWiring 46 GWiring diagram, 30 kW .. 47 HCommissioning 48 ICommissioning Flow Chart .. Ecotec plus Installation and Maintenance instructions31 Intended useThe product is intended as a heat generatorfor open and sealed heating installations andfor domestic hot water use of any kind is use also includes the following: use of the product only in mobile homesthat are made, transported once and per-manently situated in Great Britain and Ire-land.

6 After the transportation of the mo-bile home to its destination the completeproduct must be checked for leak-tightnessagain validity of the product only for Great Britainand Ireland and for the gas types in GreatBritain and Ireland as listed on the dataplate Installing and operating the product onlyin conjunction with accessories for theair/flue pipe which are listed in the otherapplicable documents and comply with thetype of unit Using the product while observing the ac-companying operating, Installation andmaintenance instructions for the productalong with all other components of the in-stallation Installing and setting up the product whileobserving the product and system ap-proval Observing all inspection and maintenanceconditions listed in the instructions Installing while observing the IP codeThe following is classed as improper use: Using the product in vehicles, such as mo-bile homes or caravans.

7 Units that are notclassed as vehicles are those that are in-stalled in a fixed and permanent location(known as "fixed Installation "). Any direct use in industrial or commercialprocesses Any use other than those described inthese instructions and any use that goesbeyond what is described QualificationThe person carrying out the work describedhere must have completed professional train-ing. The competent person must demon-strably have all of the knowledge, skills andcapabilities that are required in order to carryout the work mentioned following work must only be carried outby competent persons who are sufficientlyqualified to do so: Set-up Dismantling Installation Start-up Inspection and Maintenance Repair Decommissioning Proceed in accordance with current tech-nology.

8 Use the correct above-mentioned work must always onlybe carried out by persons with sufficient product can be used by children overeight years old and also by persons with lim-ited physical, sensory or mental capabilitiesor insufficient experience and/or knowledge ifthey are supervised or have been providedwith instructions on how to safely use theproduct, and they understand the risks res-ulting from using the product. Children mustnot play with the product. Cleaning and usermaintenance work must not be carried out bychildren unless they are General safety informationThe following sections convey importantsafety information.

9 It is essential to read andobserve this information in order to preventrisk of death, risk of injury, material damageor environmental GasIf you smell gas: Avoid rooms that smell of gas. If possible, open doors and windows fullyand ensure adequate ventilation. Do not use naked flames ( lighters,matches). Do not and Maintenance instructions Ecotec plus 0020238195_07 Do not use any electrical switches, mainsplugs, doorbells, telephones or other com-munication systems in the building. Close the emergency control valve or themain isolator.

10 If possible, close the gas stopcock on theproduct. Warn other occupants in the building byyelling or banging on doors or walls. Leave the building immediately and ensurethat others do not enter the building. Notify the gas supply company orthe Emergency Service Provider+44 (0) 800 111999 by telephone once youare outside of the Flue gasFlue gases may cause poisoning, while hotflue gases may also cause burns. Flue gasesmust therefore never be allowed to to do if you smell flue gas in the prop-erty: Open all accessible doors and windowsfully to provide ventilation.


Related search queries