SMA Solar Technology AG | Sonnenallee 1 | 34266 Niestetal | Germany Phone: +49 561 9522-0 | Fax: +49 561 9522-100 | Internet: | E-mail: Register court: Amtsgericht Kassel HRB 3972. Chairman of the Supervisory Board: G nther Cramer Managing Board: J rgen Dolle, Roland Grebe, Uwe Hertel, Pierre-Pascal Urbon, Marko Werner EN 50438 . Type certification test result sheet Manufacturer SMA Solar Technology AG. Adress Sonnenallee 1. Postal code, place 34266 Niestetal Country Germany Phone +49 561 9522-0. Test house Details SMA Solar Technology AG. Date of test 2010/08/26 (Grid monitoring tests). Type reference Max AC power Nominal AC power SB 3000TL-20 3 000 W 3 000 W. WB 3600TL-20 3 600 W 3 600 W. SB 4000TL-20 4 000 W 4 000 W.

Title: EN 50438 Type certification test result sheet - SUNNY BOY/WINDY BOY Author: SMA Solar Technology AG Subject: Zertifikat Created Date: 9/15/2011 2:02:21 PM

Tags:

  En 50438, 50438

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EN 50438 Type certification test result sheet - …

1 SMA Solar Technology AG | Sonnenallee 1 | 34266 Niestetal | Germany Phone: +49 561 9522-0 | Fax: +49 561 9522-100 | Internet: | E-mail: Register court: Amtsgericht Kassel HRB 3972. Chairman of the Supervisory Board: G nther Cramer Managing Board: J rgen Dolle, Roland Grebe, Uwe Hertel, Pierre-Pascal Urbon, Marko Werner EN 50438 . Type certification test result sheet Manufacturer SMA Solar Technology AG. Adress Sonnenallee 1. Postal code, place 34266 Niestetal Country Germany Phone +49 561 9522-0. Test house Details SMA Solar Technology AG. Date of test 2010/08/26 (Grid monitoring tests). Type reference Max AC power Nominal AC power SB 3000TL-20 3 000 W 3 000 W. WB 3600TL-20 3 600 W 3 600 W. SB 4000TL-20 4 000 W 4 000 W.

2 SB 5000TL-20 5 000 W 4 600 W. WB 5000TL-20 5 000 W 4 600 W. The results of the EN 50438 tests are summarized in this certificate. This includes the standard requirements of the EN 50438 . The country specific requirements (national deviations) are not covered by this certificate. The complete documentation can be viewed at SMA (headquarters) after prior announcement. Test results: Power quality Harmonic current emissions as per EN 61000-3-2 Class A. Harmonic 2nd 3rd 5th 7th 9th 11th 13th 15th .. 39th EN 61000-3-2 Limit [A] x (15/n). SB 3000TL-20 < limit WB 3600TL-20 < limit Test Values [A]. 1/2. (at rated power) SB 4000TL-20 < limit TR50438_SBWBTL-ZEEN113310. SB 5000TL-20 < limit WB 5000TL-20 < limit Voltage fluctuations and flicke ras per EN 61000-3-3.

3 Starting stopping running (at rated power). EN 61000-3-3 Limit 4% 4% Pst = Plt = Test value < < Power factor EN 50438 Limit lag -- lead Test level (AC voltage) 210 V 230 V 250 V. Tets value (at rated power) > > > Grid monitoring Under / Over voltage test Under Voltage Over Voltage Parameter Voltage Time Voltage Time EN 50438 Limit 230 V - 15% s 230 V + 15% s Actual setting V s V s Trip values V* s V s * Test is passed because the accuracy of the volatage measurement is 1% ( V). Under / Over frequency test Under Frequency Over Frequency Parameter Frequency Time Frequency Time EN 50438 Limit 47 Hz s 51 Hz s Actual setting 47 Hz s 51 Hz s Trip values Hz s Hz s Fault level contribution Fault level contribution (for electronic inverter).

4 Device Max short circuit current SB 3000TL-20 kA. WB 3600TL-20 kA. SB 4000TL-20 kA. SB 5000TL-20 kA. WB 5000TL-20 kA. Note: The above mentioned inverters are equipped with an overcurrent monitoring unit which can switch off the inverter in a short time (e. g. < 1 ms). 2/2. TR50438_SBWBTL-ZEEN113310.