Example: biology

INSTALLATION AND OPERATING INSTRUCTIONS …

671 0294 MODELSHPMEDIUM HEAD MODELSHIGH HEAD MODELS1/3 JBMB-56S JMB-56L JBHB-61S JHB-61HL 1/2 JBMC-56 SJBMC3-56 SJMC-56 LJMC3-56 JBHC-61 SJBHC3-61 SJHC-61 HLJHC3-61H3/4 JBMD-57 SJBMD3-57 SJMD-57 LJMD3-57 JBHD-62 SJBHD3-62 SJHD-62 HLJHD3-62H1 JBME-58 SJBME3-58 SJME-58 LJME3-58 JBHE-63 SJBHE3-63 SJHE-63 HLJHE3-63H1-1/2 JBMF-40 SJBMF3-40 SJMF-40 LJMF3-40 JBHF-51 SJBHF3-51 SJHF-51 HLJHF3-51H2 JBMG-41 SJBMG3-41 SJMG-41 LJMG3-41 JBHG-52 SJBHG3-52 SJHG-52 HLJHG3-52H2-1/2 JBMMG-59 SJBMMG3-59S JBHHG-53 SJBHHG3-53 SJHHG-53 HLJHHG3-53 HOWNER S MANUAL60 Cycle J and JB SeriesCentrifugal PumpINSTALLATION AND OPERATING INSTRUCTIONSREPAIR PARTS LIST 2014 Pentair Ltd.

3 California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

Tags:

  Operating, Installation, Instructions, Installation and operating instructions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INSTALLATION AND OPERATING INSTRUCTIONS …

1 671 0294 MODELSHPMEDIUM HEAD MODELSHIGH HEAD MODELS1/3 JBMB-56S JMB-56L JBHB-61S JHB-61HL 1/2 JBMC-56 SJBMC3-56 SJMC-56 LJMC3-56 JBHC-61 SJBHC3-61 SJHC-61 HLJHC3-61H3/4 JBMD-57 SJBMD3-57 SJMD-57 LJMD3-57 JBHD-62 SJBHD3-62 SJHD-62 HLJHD3-62H1 JBME-58 SJBME3-58 SJME-58 LJME3-58 JBHE-63 SJBHE3-63 SJHE-63 HLJHE3-63H1-1/2 JBMF-40 SJBMF3-40 SJMF-40 LJMF3-40 JBHF-51 SJBHF3-51 SJHF-51 HLJHF3-51H2 JBMG-41 SJBMG3-41 SJMG-41 LJMG3-41 JBHG-52 SJBHG3-52 SJHG-52 HLJHG3-52H2-1/2 JBMMG-59 SJBMMG3-59S JBHHG-53 SJBHHG3-53 SJHHG-53 HLJHHG3-53 HOWNER S MANUAL60 Cycle J and JB SeriesCentrifugal PumpINSTALLATION AND OPERATING INSTRUCTIONSREPAIR PARTS LIST 2014 Pentair Ltd.

2 All Rights Reserved. S873 (Rev. 12/16/14)293 WRIGHT STREET, DELAVAN, WI 53115 : 888-782-7483 Support suction pipeas requiredSupport discharge pipe as requiredAs closeas possible4 x "D"minimumFoot ValvePipe diameter"D"Straight run, short aspossible but at least 6times pipe diameter ("D")sloping away from pumpShort length of straight pipeafter reducerImportant:All connections mustbe air tightEccentricReducerSolid, levelbaseTee andPriming PlugRotated VoluteGateValveUnionDischarge to serviceRecommended pump suctionand discharge connectionsVentPlugPrimingPlugStreet ElbowNot recommended pump suctionand discharge connections Elbow immediately in front of pump the discharge avoid.

3 Quick closing turns in piping diameter "D"insufficient sizePipe submergedless than 4 x "D"will cause vortexingLong suctionrunConcentricReducerUse of excess fittingsmeans potential air leaksValveUnsupportedPipeConcentric Reducer causes highspots along the suction line resultingin air 0294 Figure 1 Figure 223 California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive - GENERALS upport both suction and discharge piping independently at a point near the pump to avoid putting a strain on the pump housing.

4 Start all piping AT THE pipe diameter at both the suction and discharge by one (1) standard pipe size (minimum) to obtain desired performance and flow rate. Refer to Table I when sizing pipe for your pumping : Do not use pipe with smaller diameter on the suction side of I Pipe Tapping Recommended Size On Pump Pipe Size Suction Discharge Suction Discharge 1-1/4 1 1-1/2 1-1/4 1-1/2 1-1/4 2 1-1/2 2 1-1/2 3 2 SUCTION PIPEI ncrease pipe size from pump tapping as shown in Table 1 (Page 2) depicts a recommended run of pipe and fittings for the suction side of a centrifugal pump.

5 Please refer to this illustration when choosing pipe and fittings for your suction : All connections must be air tight!Figure 2 (Page 2) depicts conditions that are NOT DESIRABLE on the suction side of a centrifugal pump and may cause problems in flow rate and priming. Please look this illustration over carefully before choosing pipe and fittings for your suction PIPINGI ncrease pipe size from pump tapping as show in Table I. Figure 1 (Page 2) depicts a recommended run of pipe and fittings for the discharge.

6 Install tee with priming plug as close to pump as possible. Figure 2 (Page 2) notes conditions that should be avoided. Please read over carefully before making discharge THE PUMPA pump is primed when all air in the suction line and pump volute has been evacuated and replaced with Prime:1. Close valve in discharge Remove priming plug from tee and fill pump and suction line with water until water is flowing back out of Replace priming Start pump and slowly open valve until desired water flow is achieved.

7 NOTICE: If water is not being pumped, turn off pump, close valve, and repeat steps 1 thru pump volute is rotated as shown in Figure 1 (Page 2), loosen vent plug when priming to evacuate air trapped inside volute and tighten when volute is completely filled with water. Risk of explosion and scalding. Never run pump against closed discharge. To do so can boil water inside pump, causing hazardous pressure buildup and possible explosion. Risk of flooding. Do not run the pump dry. This will damage mechanical seal and void warranty.

8 It may cause burns to person handling pump. Motor normally operates at high temperature and will be too hot to touch. It is protected from heat damage during operation by an automatic internal cutoff switch. Before handling pump or motor, stop motor and allow it to cool for 20 II - RECOMMENDED FUSING AND WIRING DATA - 60 CYCLE MOTORSMOTORHPMAX. LOADAMPERESBRANCHFUSE*RATINGAMPSDIAMETER IN FEET FROM MOTOR TO METER0 TO 50 51 TO 100 101 TO 200 201 TO 300 301 TO 400 401 TO 500 WIRE SIZESINGLE PHASE - 115/230 VOLT1 PHASE - 230/460 VOLT1 * Time delay fuse or circuit breakers are recommended in any motor diagram for dual voltage, single-phase motors.

9 Your dual-voltage motor s terminal board (under the motor end cover) will match one of the diagrams below. Follow that diagram if necessary to convert motor to 115 Volt power. Connect power supply wires to L1 and L2. For 3-phase motors, or if motor does not match these pictures, follow the connection diagram on the motor MOTOR IS SET FOR 230 VOLTS WHEN change the motor to use 115 volts:1. Turn off power2. Remove the back motor Use a screwdriver or 1/2 wrench and turn the voltage selector dial counterclockwise until 115 shows in the dial Reinstall the motor cover.

10 Hazardous voltage. Can shock, burn, or cause death. Disconnect power to motor before working on pump or motor. Ground motor before connecting to power Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Supply voltage must be within 10% of nameplate voltage. Incorrect voltage can cause fire or damage motor and voids warranty.


Related search queries