1 SSINAMICSSINAMICS G120 CList Manual04/2014 EditionAnswers for AASINAMICSSINAMICS G120 CList ManualFundamental safety instructions1 Parameters2 Function diagrams3 Faults and alarms4 AppendixAIndexValid forDriveFirmware versionSINAMICS notice systemThis Manual contains information which you must observe to ensure your own personal safety as well as to avoid material damage. The notices referring to your personal safety are highlighted in the Manual by a safety alert symbol, notices referring only to equipment damage have no safety alert symbol. Depending on the hazard level, warnings are indicated in a descending order as follows:If more than one level of danger is simultaneously applicable, the warning notice for the highest level is used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property personnelThe product/system described in this documentation may only be operated by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions.
2 Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these Use of Siemens ProductsNote the following:TrademarksAll names identified with are registered trademarks of Siemens AG. Any other names used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the of liabilityWe have checked the contents of this publication for consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. The information given in this document is reviewed at regular intervals and any corrections that might be necessary are made in the subsequent that death or serious injury will result if proper precautions are not that death or serious injury could result if proper precautions are not that minor personal injury can result if proper precautions are not that property damage can result if proper precautions are not products are only permitted to be used for the applications listed in the catalog and in the associated technical documentation.
3 If third-party products and components are used, then they must be recommended or approved by Siemens . These products can only function correctly and safely if they are transported, stored, set up, mounted, installed, commissioned, operated and maintained correctly. The permissible ambient conditions must be adhered to. Notes in the associated documentation must be AGIndustry SectorPostfach 48 4890026 NUREMBERGGERMANYD ocument order number: A5E33840768B AA04/2014 Subject to changeCopyright Siemens AG rights reservedLegal informationSINAMICS G120C List Manual (LH13), 04/2014, A5E33840768B AA 5 Table of contents1 Fundamental safety instructions.. safety instructions.. security .. 92 Parameters.. of parameters .. of the parameter list .. ranges of parameters .. of parameters .. for data sets .. Data Set (CDS).. Data Sets (DDS) .. data sets (MDS) .. unit Data Sets (PDS).. Data Sets (EDS) .. parameters (connectors/binectors).. inputs (BI).
4 Inputs (CI) .. outputs (BO).. outputs (CO) .. outputs (CO/BO) .. for write protection and know-how protection .. with "WRITE_NO_LOCK" .. with "KHP_WRITE_NO_LOCK" .. with "KHP_ACTIVE_READ" .. commissioning (p0010 = 1) .. 3143 Function diagrams .. of contents .. of the function diagrams .. terminals.. communication (PROFIBUS/PROFINET) .. communication .. , fieldbus interface (USS, MODBUS) .. control/status words .. control .. Integrated Basic Functions .. Integrated PROFI safe .. 392 Table of contentsSINAMICS G120C 6 List Manual (LH13), 04/2014, A5E33840768B channel .. control .. functions .. controller .. and monitoring functions .. sets .. 4484 Faults and alarms .. of faults and alarms .. information .. of the list of faults and alarms.. ranges of faults and alarms .. of faults and alarms .. 463 AAppendix .. table (characters that can be displayed) .. of abbreviations .. 551 Index.. 5611 SINAMICS G120C List Manual (LH13), 04/2014, A5E33840768B AA 7 Fundamental safety safety security91 Fundamental safety General safety instructionsSINAMICS G120C 8 List Manual (LH13), 04/2014, A5E33840768B safety instructionsWARNINGRisk of death if the safety instructions and remaining risks are not carefully observedIf the safety instructions and residual risks are not observed in the associated hardware documentation, accidents involving severe injuries or death can occur.
5 Observe the safety instructions given in the hardware documentation. Consider the residual risks for the risk to life or malfunctions of the machine as a result of incorrect or changed parameterizationAs a result of incorrect or changed parameterization, machines can malfunction, which in turn can lead to injuries or death. Protect the parameterization (parameter assignments) against unauthorized access. Respond to possible malfunctions by applying suitable measures ( EMERGENCY-STOP or EMERGENCY-OFF).SINAMICS G120C List Manual (LH13), 04/2014, A5E33840768B AA 91 Fundamental safety Industrial securityNoteIndustrial securitySiemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, devices, and/or networks. They are important components of a holistic industrial security concept. With this in mind, Siemens products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product ensure that Siemens products and solutions are operated securely, suitable preventive measures ( cell protection concept) and each component must be integrated into a state-of-the-art holistic industrial security concept.
6 Third-party products that may be in use should also be considered. You will find more information about industrial security at: receive information about product updates on a regular basis, register for our product newsletter. You will find more information at: as a result of unsafe operating states resulting from software manipulationSoftware manipulation ( by viruses, Trojan horses, malware, worms) can cause unsafe operating states to develop in your installation which can result in death, severe injuries and/or material damage. Keep the software up to and newsletters can be found at: Incorporate the automation and drive components into a holistic, state-of-the-art industrial security concept for the installation or more information, visit: Make sure that you include all installed products into the holistic industrial security Fundamental safety Industrial securitySINAMICS G120C 10 List Manual (LH13), 04/2014, A5E33840768B AA2 SINAMICS G120C List Manual (LH13), 04/2014, A5E33840768B AA of of for data parameters (connectors/binectors) for write protection and know-how commissioning (p0010 = 1)3142 Overview of parametersSINAMICS G120C 12 List Manual (LH13), 04/2014, A5E33840768B of of the parameter listBasic structure of the parameter descriptionsThe data in the following example has been chosen at random.
7 The table below contains all the information that can be included in a parameter description. Some of the information is "List of parameters" (Page 25) has the following structure: - - - - - - - - - - - - Start of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Description:TextValue:0:Name and meaning of value 01:Name and meaning of value 12:Name and meaning of value :TextIndex:[0] = Name and meaning of index 0[1] = Name and meaning of index 1[2] = Name and meaning of index :TextRefer to: pxxxx, rxxxxRefer to: Fxxxxx, AxxxxxNote:Information that might be useful. - - - - - - - - - - - - End of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -The individual pieces of information are described in detail [ ] BICO: Full parameter name / abbreviated nameCU/PM variantsAccess level: 3 Calculated: p0340 = 1 Data type: FloatingPoint32 Can be changed: C(x), U, TScaling: p2002 Dyn.
8 Index: CDS, p0170 Unit group: 6_2 Unit selection: p0505 Func. diagram: 8070 MinMaxFactory [Nm] [Nm] [Nm]Bit field:BitSignal name1 signal0 signalFP00 Name and meaning of bit 0 Yesno806001 Name and meaning of bit 1 Yesno-02 Name and meaning of bit :Warning:Caution:Safety notices with a warning triangleNotice:Safety notice without a warning triangleSINAMICS G120C List Manual (LH13), 04/2014, A5E33840768B AA 132 Overview of parameterspxxxx[ ]Parameter numberThe parameter number is made up of a "p" or "r", followed by the parameter number and the index or bit field (optional).Examples of the representation in the parameter list:Other examples of the notation in the documentation:The following applies to adjustable parameters:The parameter value as delivered is specified under "Factory setting" with the relevant unit in square brackets. The value can be adjusted within the range defined by "Min" and "Max".The term "linked parameterization" is used in cases where changes to adjustable parameters affect the settings of other parameterization can occur, for example, as a result of the following actions and parameters: Setting the PROFIBUS telegram (BICO interconnection)p0922 Set component listsp0230, p0300, p0301, p0400 Automatic calculation and pre-assignmentp0340, p3900 Restoring the factory settingsp0970 The following applies to display parameters:The fields "Min", "Max" and "Factory setting" are specified with a dash "-" and the relevant unit in square brackets.
9 Parameters (read and write parameters) Display parameters (read only) p0918 Adjustable parameter 918 p2051[ ]Adjustable parameter 2051, indices 0 to 13 p1001[ ]Adjustable parameter 1001, indices 0 to n (n = configurable) r0944 Display parameter 944 parameter 2129 with bit field from bit 0 (smallest bit) to bit 15 (largest bit) p1070[1]Adjustable parameter 1070, index 1 p2098[1].3 Adjustable parameter 2098, index 1 bit 3 parameter 795, bit 4 NoteThe parameter list can contain parameters that are not visible in the expert lists of the particular commissioning software ( parameters for trace functions).2 Overview of parametersSINAMICS G120C 14 List Manual (LH13), 04/2014, A5E33840768B AABICO: Full parameter name / abbreviated nameThe following abbreviations can appear in front of the BICO parameter name: G120C variantsSpecifies for which G120C variants (communication) the parameter is valid is. If no G120C variant is listed, then the parameter is valid for all following information relating to " G120C variants" can be displayed under the parameter number: BI:Binector Input This parameter is used for selecting the source of a digital signal.
10 BO:Binector output This parameter is available as a digital signal for interconnection with other parameters. CI:Connector Input This parameter is used for selecting the source of an "analog" signal. CO:Connector output This parameter is available as an "analog" signal for interconnection with other parameters. CO/BO: Connector/Binector Output This parameter is available as an "analog" and digital signal for interconnection with other BICO input (BI/CI) cannot be interconnected with just any BICO output (BO/CO, signal source).When interconnecting a BICO input using the commissioning software, only the corresponding possible signal sources are diagrams 1020 .. 1030 explain the symbols for BICO parameters and how to deal with BICO 2-1 Information in the "CU/PM variants" fieldCU/PM variantsMeaningAll G120C variants have this with CAN interfaceG120C_DPG120C with PROFIBUS interfaceG120C_PNG120C with PROFINET interfaceG120C_USSG120C with USS interfaceSINAMICS G120C List Manual (LH13), 04/2014, A5E33840768B AA 152 Overview of parametersAccess levelSpecifies the minimum access level required to be able to display and change the relevant parameter.