Model q46n . Dissolved Ammonia Measurement System Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA19426 Delph New Road, Delph Saddleworth OL3 5DE. Ph: 800-959-0299 Ph: +44 (0)1457-873-318. 610-917-0991. Fax: 610-917-0992 Fax: + 44 (0)1457-874-468. Email: PRODUCT WARRANTY. Analytical Technology, Inc. (Manufacturer) warrants to the Customer that if any part(s). of the Manufacturer's equipment proves to be defective in materials or workmanship within the earlier of 18 months of the date of shipment or 12 months of the date of start- up, such defective parts will be repaired or replaced free of charge.

5 O&M Manual Rev-L (5/16) Part 1 - Introduction 1.1 General The Model Q46N is an on-line monitoring system designed for the continuous measurement of dissolved ammonia in aqueous solution.

Tags:

  Model, Model q46n, Q46n

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Model Q46N - Gas Monitors and Water Quality Monitors

1 Model q46n . Dissolved Ammonia Measurement System Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA19426 Delph New Road, Delph Saddleworth OL3 5DE. Ph: 800-959-0299 Ph: +44 (0)1457-873-318. 610-917-0991. Fax: 610-917-0992 Fax: + 44 (0)1457-874-468. Email: PRODUCT WARRANTY. Analytical Technology, Inc. (Manufacturer) warrants to the Customer that if any part(s). of the Manufacturer's equipment proves to be defective in materials or workmanship within the earlier of 18 months of the date of shipment or 12 months of the date of start- up, such defective parts will be repaired or replaced free of charge.

2 Inspection and repairs to products thought to be defective within the warranty period will be completed at the Manufacturer's facilities in Collegeville, PA. Products on which warranty repairs are required shall be shipped freight prepaid to the Manufacturer. The product(s) will be returned freight prepaid and allowed if it is determined by the manufacturer that the part(s) failed due to defective materials or workmanship. This warranty does not cover consumable items, batteries, or wear items subject to periodic replacement including lamps and fuses.

3 Gas sensors carry a 12 months from date of shipment warranty and are subject to inspection for evidence of misuse, abuse, alteration, improper storage, or extended exposure to excessive gas concentrations. Should inspection indicate that sensors have failed due to any of the above, the warranty shall not apply. The Manufacturer assumes no liability for consequential damages of any kind, and the buyer by acceptance of this equipment will assume all liability for the consequences of its use or misuse by the Customer, his employees, or others.

4 A defect within the meaning of this warranty is any part of any piece of a Manufacturer's product which shall, when such part is capable of being renewed, repaired, or replaced, operate to condemn such piece of equipment. This warranty is in lieu of all other warranties ( including without limiting the generality of the foregoing warranties of merchantability and fitness for a particular purpose), guarantees, obligations or liabilities expressed or implied by the Manufacturer or its representatives and by statute or rule of law.

5 This warranty is void if the Manufacturer's product(s) has been subject to misuse or abuse, or has not been operated or stored in accordance with instructions, or if the serial number has been removed. Analytical Technology, Inc. makes no other warranty expressed or implied except as stated above Table of Contents TABLE OF 4. PART 6 CALIBRATION ..52. PART 1 - INTRODUCTION .. 5. Ammonia General .. 5 Ammonia ZeroCal ..52. Standard System .. 6 Ammonia SpanCal ..53. Features .. 6 Temperature Calibration ..55. q46n System Specifications.

6 7. PART 7 PID CONTROLLER DETAILS ..56. q46n Performance Specifications .. 9. PID Description ..56. PART 2 MECHANICAL INSTALLATION ..10. PID Algorithm ..56. General ..10 Classical PID Tuning ..58. Wall or Pipe Common PID Pitfalls ..59. Panel Mount ..15. PART 8 SYSTEM MAINTENANCE ..60. Chemistry Module Mounting Dimensions 16 General ..60. Analyzer Maintenance ..60. PART 3 ELECTRICAL INSTALLATION ..17. Sensor Maintenance ..60. General ..17 Sensor Acid Cleaning ..61. Monitor Power Connection ..17 Inlet Filter Maintenance ..62. Chemistry Module Power Connection.

7 22 Flow Cell Maintenance ..62. PART 4 CHEMISTRY SYSTEM ASSY ..23 PART 9 TROUBLESHOOTING ..65. Chemistry Module ..23 General ..65. Sensor Preparation ..23 External Sources of Problems ..65. Sensor Analyzer Tests ..66. Reagent Preparation ..25 Chemistry System Tests ..67. Reagent Connections ..27 Display Messages ..68. Reagent Bottle Holders ..28 Sensor Tests ..70. Inlet Filter SPARE PARTS ..72. PART 5 CONFIGURATION ..30. SPARE PARTS ..73. User Interface ..30. Keys ..31. Display ..31..31. Software ..33. Software Navigation ..33. Measure Menu [MEASURE].

8 36. Calibration Menu [CAL]..37. Configuration Menu [CONFIG] ..38. Control Menu [CONTROL] ..42. Diagnostics Menu [DIAG] ..47. 3. O&M Manual Rev-K (7/15). Table of Figures FIGURE 1 - q46n STANDARD 11. FIGURE 2 - Q46 ENCLOSURE DIMENSIONS .. 12. FIGURE 3 - WALL OR PIPE MOUNT BRACKET .. 13. FIGURE 4 - WALL MOUNTING DIAGRAM .. 14. FIGURE 5 - PIPE MOUNTING 14. FIGURE 6 - PANEL MOUNT AND CUTOUT .. 15. FIGURE 7 - CHEMISTRY SYSTEM DIMENSIONAL .. 16. FIGURE 8 - q46n AC POWER CONNECTION .. 18. FIGURE 9 - q46n EXTERNAL CONNECTIONS .. 19. FIGURE 10 - RELAY CONTACTS.

9 20. FIGURE 11 - OPTIONAL RELAY BOARD WIRING .. 21. FIGURE 12 - OPTIONAL ANALOG OUTPUT WIRING .. 21. FIGURE 13 - ELECTRICAL CONNECTIONS, SEPARATED SYSTEM .. 22. FIGURE 14 - SENSOR ASSEMBLY .. 24. FIGURE 15 - REAGENT PICKUP ASSEMBLY .. 27. FIGURE 16 - REAGENT BOTTLE HOLDER .. 28. FIGURE 17 - CUSTOMER INLET 29. FIGURE 18 - USER 30. FIGURE 19 - SOFTWARE MAP .. 35. FIGURE 20 - CONTROL RELAY EXAMPLE .. 45. FIGURE 21 - ALARM RELAY 46. FIGURE 22 - ISA (IDEAL) EQUATION .. 57. FIGURE 23 - INLET FLOWBLOCK EXPLODED VIEW .. 63. FIGURE 24 - SYSTEM FITTINGS EXPLODED VIEW.

10 64. FIGURE 25 - q46n DISPLAY MESSAGES .. 68. FIGURE 26 - q46n DISPLAY MESSAGES (CONT'D) .. 69. FIGURE 27 - PT100 RTD TABLE .. 71. 4. O&M Manual Rev-K (7/15). Part 1 - Introduction General The Model q46n is an on-line monitoring system designed for the continuous measurement of dissolved ammonia in aqueous solution. The full scale display range of the system is ppm, but the chemistry used in the monitor limits the reliable range of operation to PPM. The sensing system will operate on Water streams with temperatures ranging from 5 to 40 C.