Example: biology

MRH - SOFIMA HYDRAULIC FILTERS

MRHRETURN FILTERR eturn FiltersMRH 2 MPa (20 bar)Port sizes: 1/2 3 1/2 Flow rates: 3 l/minTECHNICAL DATAMax. working pressure: 2 MPa (20 bar)Max. test pressure: 3 MPa (30 bar)Bursting pressure: 6 MPa (60 bar)Fatigue test: 0 1,5 MPa (15 bar) / cycles Bypass valve: p 300 kPa (3 bar) 10% filter element collapse pressure:standard: p 1 MPa (10 bar)Working temperature: -25 +110 CMATERIALSHead: anodized aluminiumBowl: anodized aluminium (steel for size 250 only) Seals: standard NBRon request FKMCOMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test.

CLOGGING INDICATORS 64,5 30 48 35 M20 x 1,5 G R 2 3 1+ 4-N.C. N.O. C Setting 200 kPa (2 bar) NBR FKM 7C EC Differential ELECTRICAL …

Tags:

  Filter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MRH - SOFIMA HYDRAULIC FILTERS

1 MRHRETURN FILTERR eturn FiltersMRH 2 MPa (20 bar)Port sizes: 1/2 3 1/2 Flow rates: 3 l/minTECHNICAL DATAMax. working pressure: 2 MPa (20 bar)Max. test pressure: 3 MPa (30 bar)Bursting pressure: 6 MPa (60 bar)Fatigue test: 0 1,5 MPa (15 bar) / cycles Bypass valve: p 300 kPa (3 bar) 10% filter element collapse pressure:standard: p 1 MPa (10 bar)Working temperature: -25 +110 CMATERIALSHead: anodized aluminiumBowl: anodized aluminium (steel for size 250 only) Seals: standard NBRon request FKMCOMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test.

2 For further information contact our Technical FiltersMRHMRH TypeType 008015 CRH025070150250 FTFCFDFVCDCVMSMNFT = 5 m(c)FC = 7 m(c)FD = 12 m(c)FV = 21 m(c)CD = 10 CV = 25 MS = 60 MN = 90 FT = 5 m(c)FC = 7 m(c)FD = 12 m(c)FV = 21 m(c)CD = 10 CV = 25 MS = 60 MN = 90 FTFCFDFVCDCVMSMNFTFCFDFVCDCVMSMNFTFCFDFV CDCVMSMNFTFCFDFVCDCVMSMNFTFCFDFVCDCVMSMN 121 = NBR Nitrile2 = FKM Fluoroelastomer1 = NBR Nitrile2 = FKM Fluoroelastomer1212121212 Bypass typeSDSDSDSDSDSDS = WhitoutD = 300 kPa (3 bar)Ports B = BSPN = NPTS = SAEF = SAE flange 3000 psiBNS-BNS-BNSFBNSFBNSF---FPort size3-----3 = 1/2 4 = 3/4 5 = 1 7 = 1 1/29 = 2 1/2B = 3 1/2-4------5------7------9------BAccesso riesXXXX = No accessory availableXXXXXXXXXXXXI ndicators035C6C7CT103 = Port, plugged5C = Visual differential 200 kPa (2 bar) 6C = Electrical differential 200 kPa (2 bar)7C = 6C with LEDT1 = Electrical 200 kPa (2 bar) with thermostat 30 C 035C6C7CT1035C6C7CT1035C6C7CT1035C6C7CT1 035C6C7CT1 Inorganic fiber >1000 Paper Inorganic fiber >1000 Paper Steel wire mesh filter mediaFilter mediaSealsSealsIndicator 71 on request onlyWhen the filter is ordered with FKM seals, the first digit of the indicator codeis a letter (please see page 188-189).

3 Steel wire mesh HOW TO ORDER THE COMPLETE FILTERHOW TO ORDER THE filter ELEMENTR eturn FiltersMRHD5D4D290 H1630RD1H4D6H6H5H3H2D3E3E2E1D5D4D290 H1630RD1H4D6H6H5H3H2D3E3E2E1 Indicator portType 250: port not availableTypeD1H1D2H2D3H3E1E2E3D4H4D5D6H 5H6 RWeight KgMRH ,5905,562,531,53105===1211286,53110===13 51476,5415552,426,2M101621748,542407035, 7M12M12M1623725410,5117,5105140177218827 588,950,89513815418027527523730014,54357 6782178160191250323420673=96100971551922 48526382911304688101055251,32,63,76,514, 249,0120,769,91/2 BSP1/2 NPTSAE 8-3/4 -16 UNF3/4 BSP3/4 NPTSAE 12-1 1/16 -12UN1 BSP1 NPTSAE 16-1 5/16 -12UN1 SAE 30001 1/2 BSP1 1/2 NPTSAE 24-1 7/8 -12UN1 1/2 SAE 30002 1/2 BSP2 1/2 NPTSAE 32-2 1/2 -12UN2 1/2 SAE 30003 1/2 SAE 3000 DIMENSIONAL LAYOUT(mm)Return FiltersMRHCLOGGING INDICATORS64,5304835M20 x 1,5GR231+ 200 kPa (2 bar)NBRFKM7 CECD ifferential ELECTRICAL indicator with LED (24V) for visual indicatorSPDT differential switch.

4 14 - 30 V: > max resistive or inductive load 4 - 3 A 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Recommended tightening torque 90 Nm23164,5304835M20 x 1,5 Setting 200 kPa (2 bar)NBRFKM6 CCCD ifferential ELECTRICAL indicator SPDT differential switch. 14 - 30 V: > max resistive or inductive load 4 - 3 A 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Recommended tightening torque 90 Nm35,530 30M20 x 1,5 Setting 200 kPa (2 bar)NBRFKM5 CACD ifferential VISUAL indicator Recommended tightening torque 90 NmO30 C704830M20 x 1,5 Setting 200 kPa (2 bar)NBRFKM71E1 Differential VISUAL ELECTRICAL indicator SPDT differential switch. 14 - 30 V: > max resistive or inductive load 4 - 3 A 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Recommended tightening torque 90 Nm705932M20 x 1,5O30 CSetting 200 kPa (2 bar)NBRFKMT1 DCDifferential ELECTRICAL indicator with THERMOSTAT 30 CSPDT differential switch.

5 14 - 30 V: > max resistive or inductive load 4 - 3 A 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Recommended tightening torque 90 NmReturn FiltersMRHTypeCRH 008 CRH 015 CRH 025 CRH 070 CRH 150 CRH 2503,45,79,225,349,495,42,64,06,918,435, 669,05,710,317,243,792,0172,54,06,910,32 8,757,5109,2 filter MediaFCFTFVFD p = 50 kPa (0,5 bar)380990160042808350176003809901600428 0835017600 TypeFilter Media32552080023304065100003255208002330 406510000 MNMSCDCVCRH 008 CRH 015 CRH 025 CRH 070 CRH 150 CRH 250 TypeMRH 008 MRH 015 MRH 025 MRH 070 MRH 150 MRH 2509223815026057031022621253503070110280 4808004590160350650100023458022038075030 7011028048080060115180410100011206512520 045010501200 FCFTFVCVFDCDMNMSF ilter MediaTechnical data subject to variations without prior notice. MRH 07/2013 FLOW RATES(l/min)DIRT HOLDING CAPACITY(g) ISO MTD p = 300 kPa (3 bar) filter AREA(cm2)The reference fluid has a kinematic viscosity of 30 cSt and a density of 0,86 different oil viscosity please contact our Sales Department for further FiltersMRH