Example: quiz answers

NI 9223 Datasheet - National Instruments

DATASHEETNI 9223 Datasheet4 AI, 10 V, 16 Bit, 1 MS/s/ch Simultaneous BNC or screw-terminal connectivity 60 VDC, CAT I, channel-to-channel isolationThe NI 9223 C Series module is a high-speed, simultaneous module for use in anyNI CompactDAQ or CompactRIO chassis. With a sample rate of up to 1 MS/s andsimultaneous analog-to-digital converters (ADCs), this module is well-suited for applicationssuch as ballistics, impact, and blast wave kS/s800 kS/s8 Single-EndedNI 920116-BitNo250 kS/s 10 V 200 mV, 1 V, 5 V, 10 V NI 9205 Spring-Terminal,DSUBS pring-Terminal,DSUB 10 V 10 V 10 V 60 V16-Bit16-Bit16-BitYesNoYesYes100 kS/s/ch500 kS/s/ch1 MS/s/chNI 9220NI 9221NI 9222NI 922332 Single-Ended,16 differential4 Differential4 Differential16 Differential8 Single-EndedScrew-Terminal,Spring-Termin al,DSUBS crew-Terminal,Spring-Terminal,DSUBS crew-Terminal,BNCS crew-Terminal,BNC 10 VScrew-Terminal,Spring-Terminal,BNC16-Bi tYes100 kS/s/chNI 92154 DifferentialDSUB24-BitNo500 S/s 10 VNI 920932 Single-Ended, 16 DifferentialSpring-Terminal16.

12-Bit 12-Bit 500 kS/s No 800 kS/s NI 9201 8 Single-Ended 250 kS/s No 16-Bit ±10 V ±200 mV, ±1 V, ±5 V, ±10 V NI 9205 Spring-Terminal, DSUB Spring-Terminal, DSUB ±10 V

Tags:

  Datasheet, National, Instruments, National instruments, 2239, 12 bit, Ni 9223 datasheet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of NI 9223 Datasheet - National Instruments

1 DATASHEETNI 9223 Datasheet4 AI, 10 V, 16 Bit, 1 MS/s/ch Simultaneous BNC or screw-terminal connectivity 60 VDC, CAT I, channel-to-channel isolationThe NI 9223 C Series module is a high-speed, simultaneous module for use in anyNI CompactDAQ or CompactRIO chassis. With a sample rate of up to 1 MS/s andsimultaneous analog-to-digital converters (ADCs), this module is well-suited for applicationssuch as ballistics, impact, and blast wave kS/s800 kS/s8 Single-EndedNI 920116-BitNo250 kS/s 10 V 200 mV, 1 V, 5 V, 10 V NI 9205 Spring-Terminal,DSUBS pring-Terminal,DSUB 10 V 10 V 10 V 60 V16-Bit16-Bit16-BitYesNoYesYes100 kS/s/ch500 kS/s/ch1 MS/s/chNI 9220NI 9221NI 9222NI 922332 Single-Ended,16 differential4 Differential4 Differential16 Differential8 Single-EndedScrew-Terminal,Spring-Termin al,DSUBS crew-Terminal,Spring-Terminal,DSUBS crew-Terminal,BNCS crew-Terminal,BNC 10 VScrew-Terminal,Spring-Terminal,BNC16-Bi tYes100 kS/s/chNI 92154 DifferentialDSUB24-BitNo500 S/s 10 VNI 920932 Single-Ended.

2 16 DifferentialSpring-Terminal16-BitNo250 kS/s 200 mV, 1 V, 5 V, 10 V NI 920632 Single-Ended,16 DifferentialDSUB24-BitNo500 S/s 10 VNI 92078 DifferentialConnectivitySampleRateChanne lsProductNameSignalLevelsC SERIES ANALOG INPUT MODULE COMPARISONR esolutionSimultaneousKit ContentsAccessories NI 9971 Backshell Connector Kit (Screw Terminal) NI 9223 NI 9223 Getting Started Guide2 | | NI 9223 DatasheetNI C Series OverviewNI provides more than 100 C Series modules for measurement, control, and communicationapplications. C Series modules can connect to any sensor or bus and allow for high-accuracymeasurements that meet the demands of advanced data acquisition and control applications.

3 Measurement-specific signal conditioning that connects to an array of sensors and signals Isolation options such as bank-to-bank, channel-to-channel, and channel-to-earth ground -40 C to 70 C temperature range to meet a variety of application and environmentalneeds Hot-swappableThe majority of C Series modules are supported in both CompactRIO and CompactDAQplatforms and you can move modules from one platform to the other with no combines an open-embedded architecturewith small size, extreme ruggedness, and C Seriesmodules in a platform powered by the NI LabVIEW reconfigurable I/O (RIO) architecture. Each systemcontains an FPGA for custom timing, triggering, andprocessing with a wide array of available modular I/O tomeet any embedded application is a portable, rugged data acquisition platformthat integrates connectivity, data acquisition, and signalconditioning into modular I/O for directly interfacing to anysensor or signal.

4 Using CompactDAQ with LabVIEW, youcan easily customize how you acquire, analyze, visualize,and manage your measurement 9223 Datasheet | National Instruments | 3 SoftwareLabVIEW Professional Development System for Windows Use advanced software tools for large project development Generate code automatically using DAQ Assistant and InstrumentI/O Assistant Use advanced measurement analysis and digital signal processing Take advantage of open connectivity with DLLs, ActiveX,and .NET objects Build DLLs, executables, and MSI installersNI LabVIEW FPGA Module Design FPGA applications for NI RIO hardware Program with the same graphical environment used for desktop andreal-time applications Execute control algorithms with loop rates up to 300 MHz Implement custom timing and triggering logic, digital protocols.

5 AndDSP algorithms Incorporate existing HDL code and third-party IP including Xilinx IPgenerator functions Purchase as part of the LabVIEW Embedded Control and MonitoringSuiteNI LabVIEW Real-Time Module Design deterministic real-time applications with LabVIEW graphical programming Download to dedicated NI or third-party hardware for reliableexecution and a wide selection of I/O Take advantage of built-in PID control, signal processing, andanalysis functions Automatically take advantage of multicore CPUs or setprocessor affinity manually Take advantage of real-time OS, development and debuggingsupport, and board support Purchase individually or as part of a LabVIEW suite4 | | NI 9223 DatasheetNI 9223 Input CircuitryNI 9223AI+AI ADCA mplifierOvervoltage Protection Input signals on each channel are buffered, conditioned, and then sampled by an ADC.

6 Each AI channel provides an independent signal path and ADC, enabling you to sampleall channels 9223 SpecificationsThe following specifications are typical for the range -40 C to 70 C unless otherwise voltages are relative to the AI- signal on each channel unless otherwise Do not operate the NI 9223 in a manner not specified in this misuse can result in a hazard. You can compromise the safety protectionbuilt into the product if the product is damaged in any way. If the product isdamaged, return it to NI for CharacteristicsNumber of Channels4 analog input channelsADC resolution16 bitsType of ADCS uccessive approximation register (SAR)Input voltage ranges1, Measurement Voltage (AI+ to AI-)Minimum2 VTypical VMaximum VOvervoltage protection 30 VMaximum Sampling RateCompactDAQ (NI-DAQmx)1 MS/s1 Refer to the Safety Voltages section for more information about safe operating minimum measurement voltage range is the largest voltage the NI 9223 is guaranteed toaccurately 9223 Datasheet | National Instruments | 5 CompactRIOFPGA User-Controlled I/OSampling31 MS/sFPGA I/O Nodes350 kS/sTable 1.

7 AccuracyMeasurement ConditionsPercent of Reading(Gain Error)Percent of Range4(Offset Error) CalibratedMaximum (-40 C to 70 C) (23 C 5 C) (-40 C to 70 C) (23 C 5 C) drift6 ppm/ COffset drift29 V/ CCMRR (fin = 60 Hz)100 dB-3 dB bandwidth6>1 MHzInput impedance>1 G LSBrmsTotal Harmonic Distortion (THD) (20 Vppat 1 kHz)-85 dBCrosstalk (20 Vpp at 1 kHz)-100 dBPower RequirementsPower consumption from chassisActive mode1 W maximumSleep mode5 mW maximum3 FPGA User-Controlled I/O Sampling provides low level access to sample acquisition and transfer,and higher sample rates. Visit and enter the Info Code samplerate for information aboutFPGA User-Controlled I/O equals accuracy refers to the accuracy achieved when acquiring in raw or unscaled modeswhere the calibration constants stored in the module are not applied to the dB bandwidth for input amplitude at 10% of the input | | NI 9223 DatasheetThermal dissipation (at 70 C)Active W maximumSleep mode430 mW maximumPhysical CharacteristicsIf you need to clean the module, wipe it with a dry For two-dimensional drawings and three-dimensional models of the C Seriesmodule and connectors, visit and search by module mm2 to mm2 (30 AWG to 14 AWG)

8 Copper conductor wireWire strip length6 mm ( in.) of insulation stripped from theendTemperature rating90 C minimumTorque for screw N m to N m ( lb in. lb in.)Wires per screw terminalOne wire per screw terminal; two wires perscrew terminal using a 2-wire mm2 to mm2 Connector securementSecurement typeScrew flanges providedTorque for screw N m ( lb in.)WeightNI 9223 with screw terminal138 g ( oz)NI 9223 with BNC165 g ( oz)Safety VoltagesConnect only voltages that are within the following limits:IsolationChannel-to-channelContin uous60 VDC, Measurement Category IWithstand1000 Vrms, verified by a 5 s dielectricwithstand testNI 9223 Datasheet | National Instruments | 7 Channel-to-earth groundContinuous60 VDC, Measurement Category IWithstand1000 Vrms, verified by a 5 s dielectricwithstand testMeasurement Category I is for measurements performed on circuits not directly connected tothe electrical distribution system referred to as MAINS voltage.

9 MAINS is a hazardous liveelectrical supply system that powers equipment. This category is for measurements of voltagesfrom specially protected secondary circuits. Such voltage measurements include signal levels,special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and Do not connect the NI 9223 to signals or use for measurements withinMeasurement Categories II, III, or Measurement Categories CAT I and CAT O are equivalent. These test andmeasurement circuits are not intended for direct connection to the MAINS buildinginstallations of Measurement Categories CAT II, CAT III, or CAT (UL)Class I, Division 2, Groups A, B, C, D, T4;Class I, Zone 2, AEx nA IIC T4 Canada (C-UL)Class I, Division 2, Groups A, B, C, D, T4.

10 Class I, Zone 2, Ex nA IIC T4 Europe (ATEX) and International (IECEx)Ex nA IIC T4 GcSafety and Hazardous Locations StandardsThis product is designed to meet the requirements of the following electrical equipment safetystandards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 EN 60079-0:2012, EN 60079-15:2010 IEC 60079-0: Ed 6, IEC 60079-15; Ed 4 UL 60079-0; Ed 5, UL 60079-15; Ed 3 CSA 60079-0:2011, CSA 60079-15:2012 Note For UL and other safety certifications, refer to the product label or the OnlineProduct Certification | | NI 9223 DatasheetElectromagnetic CompatibilityThis product meets the requirements of the following EMC standards for sensitive electricalequipment for measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions.


Related search queries