Transcription of NI 9224 Datasheet - National Instruments
1 DATASHEETNI 92248 AI, 10 V, 24 Bit, 1 kS/s/ch Simultaneous Screw-terminal connectivity 50 Hz/60 Hz noise rejection 250 Vrms, CAT II, channel-to-channel isolationThe NI 9224 is an analog input module for use in CompactDAQ or CompactRIO channel provides a 10 V measurement range at a 24-bit resolution. The NI 9224 outputs1 kS/s of data at the maximum sampling rate. Designed for both speed and accuracy, theNI 9224 is an effective general-purpose analog module because of its resolution, sample rate,and input ContentsAccessories NI 9939 Screw Terminal Connector Backshell Kit NI 9224 NI 9224 Getting Started GuideNI C Series OverviewNI provides more than 100 C Series modules for measurement, control, and communicationapplications. C Series modules can connect to any sensor or bus and allow for high-accuracymeasurements that meet the demands of advanced data acquisition and control applications. Measurement-specific signal conditioning that connects to an array of sensors and signals Isolation options such as bank-to-bank, channel-to-channel, and channel-to-earth ground -40 C to 70 C temperature range to meet a variety of application and environmentalneeds Hot-swappableThe majority of C Series modules are supported in both CompactRIO and CompactDAQplatforms and you can move modules from one platform to the other with no combines an open-embedded architecturewith small size, extreme ruggedness, and C Seriesmodules in a platform powered by the NI LabVIEW reconfigurable I/O (RIO) architecture.
2 Each systemcontains an FPGA for custom timing, triggering, andprocessing with a wide array of available modular I/O tomeet any embedded application is a portable, rugged data acquisition platformthat integrates connectivity, data acquisition, and signalconditioning into modular I/O for directly interfacing to anysensor or signal. Using CompactDAQ with LabVIEW, youcan easily customize how you acquire, analyze, visualize, andmanage your measurement | | NI 9224 DatasheetSoftwareLabVIEW Professional Development System for Windows Use advanced software tools for large project development Generate code automatically using DAQ Assistant and InstrumentI/O Assistant Use advanced measurement analysis and digital signal processing Take advantage of open connectivity with DLLs, ActiveX, and .NETobjects Build DLLs, executables, and MSI installersNI LabVIEW FPGA Module Design FPGA applications for NI RIO hardware Program with the same graphical environment used for desktop andreal-time applications Execute control algorithms with loop rates up to 300 MHz Implement custom timing and triggering logic, digital protocols, andDSP algorithms Incorporate existing HDL code and third-party IP including Xilinx IPgenerator functions Purchase as part of the LabVIEW Embedded Control and MonitoringSuiteNI LabVIEW Real-Time Module Design deterministic real-time applications with LabVIEW graphical programming Download to dedicated NI or third-party hardware for reliableexecution and a wide selection of I/O Take advantage of built-in PID control, signal processing, andanalysis functions Automatically take advantage of multicore CPUs or setprocessor affinity manually Take advantage of real-time OS, development and debuggingsupport.
3 And board support Purchase individually or as part of a LabVIEW suiteNI 9224 Datasheet | National Instruments | 3NI 9224 Input CircuitryAI+AI ADCA mplifierOvervoltage ProtectionNI 9224 Input signals on each channel are conditioned, buffered, and then sampled by an ADC. Each AI channel provides an independent signal path and ADC, enabling you to sampleall channels ModesThe NI 9224 supports high resolution, medium resolution, high speed, and medium speedtiming modes. High resolution timing mode optimizes noise and rejects power linefrequencies. Medium resolution timing mode has a higher sample rate when compared withhigh resolution, and also rejects power line frequencies. High speed timing mode optimizessample rate and signal bandwidth, whereas medium speed timing mode has lower noise whencompared to high speed timing 9224 SpecificationsThe following specifications are typical for the range -40 C to 70 C unless otherwise voltages are relative to the AI- signal on each channel unless otherwise Do not operate the NI 9224 in a manner not specified in this misuse can result in a hazard.
4 You can compromise the safety protectionbuilt into the product if the product is damaged in any way. If the product isdamaged, return it to NI for CharacteristicsNumber of channels8 analog input channelsADC resolution24 bitsType of ADCD elta-SigmaSampling modeSimultaneous4 | | NI 9224 DatasheetTable 1. Conversion time (simultaneously sampled)Timing ModeConversion Time (ms)Sample Rate (S/s)High resolution5002 Medium speed10100 High speed11000 Input voltage ranges, AI+ to AI-Typical VMinimum VOvervoltage protection, AI+ to AI-250 VrmsInput couplingDCFigure 1. Input Bias Current 6 6 6 6 6 6 10 8 6 4 20246810 Input BIas Current (A)Input Voltage (V) 6NI 9224 Datasheet | National Instruments | 5 Table 2. NI 9224 AccuracyMeasurement ConditionsPercent of Reading(Gain Error)Percent of Range1(Offset Error)CalibratedTypical (25 C, 5 C) (-40 C to 70 C) noiseHigh resolution5 VrmsMedium resolution7 VrmsMedium speed14 VrmsHigh speed51 VrmsStabilityGain drift 17 ppm/ COffset drift 21 V/ CPost-calibration gain match (fin = 100 Hz) 75 mdB maximumPhase mismatch, channel-to-channel(fin = 100 Hz) /Hz maximumInput delayHigh msMedium msMedium msHigh ms1 Range equals V6 | | NI 9224 DatasheetFigure 2.
5 Filter Frequency (dB) 80 600 40 20 Frequency (Hz)1 k10100110 k 100 High SpeedMedium SpeedMedium ResolutionHigh ResolutionSignal input bandwidth, -3 dBHigh HzMedium HzMedium HzHigh kHzCommon-Mode Rejection Ratio (CMRR), rejection of channel-to-earth common-modevoltagesHigh resolution (fin = 50/60 Hz)160 dBMedium resolution (fin = 50/60 Hz)160 dBMedium speed (fin = 50/60 Hz)138 dBHigh speedRefer to the following figureNI 9224 Datasheet | National Instruments | 7 Figure 3. High speed CMRR (0 Hz to 500 Hz)1151201251301351401455010015020025030 0350400450500 CMRR (dB)Frequency (Hz)Normal-Mode Rejection Ratio (NMRR)High resolution (fin = 50 Hz 1 Hz or60 Hz 1 Hz)120 dB minimumMedium resolution (fin =50 Hz 1 Hz or 60 Hz 1 Hz)80 dB minimumCrosstalk (fin = 1 kHz)-125 dBAlias hole rejection ( (fin = kHz)86 dBPower RequirementsPower consumption from chassisActive mode930 mW maximumSleep mode53 W maximumThermal dissipationActive W maximumSleep mode53 W maximum8 | | NI 9224 DatasheetPhysical CharacteristicsIf you need to clean the module, wipe it with a dry For two-dimensional drawings and three-dimensional models of the C Seriesmodule and connectors, visit and search by module mm2 to mm2 (30 AWG to 14 AWG)copper conductor wireWire strip length6 mm ( in.))
6 Of insulation stripped from theendTemperature rating90 C minimumTorque for screw N m to N m ( lb in. lb in.)Wires per screw terminalOne wire per screw terminal; two wires perscrew terminal using a 2-wire mm2 to mm2 Connector securementSecurement typeScrew flanges providedTorque for screw N m ( lb in.)Weight152 g ( oz)Safety VoltagesConnect only voltages that are within the following limits:Channel-to-channel isolationUp to 2,000 m altitudeContinuous250 Vrms, Measurement Category IIWithstand1,500 Vrms, verified by a 5 s dielectric testUp to 5,000 m altitudeContinuous60 VDC, Measurement Category IWithstand1,000 Vrms, verified by a 5 s dielectric testChannel-to-earth ground isolationUp to 2,000 m altitudeContinuous250 Vrms, Measurement Category IIWithstand3,000 Vrms, verified by a 5 s dielectric testNI 9224 Datasheet | National Instruments | 9Up to 5,000 m altitudeContinuous60 VDC, Measurement Category IWithstand1,000 Vrms , verified by a 5 s dielectric testMeasurement Category I is for measurements performed on circuits not directly connected tothe electrical distribution system referred to as MAINS voltage.
7 MAINS is a hazardous liveelectrical supply system that powers equipment. This category is for measurements of voltagesfrom specially protected secondary circuits. Such voltage measurements include signal levels,special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and If using in Division 2 or Zone 2 hazardous locations applications, do notconnect the NI 9224 to signals or use for measurements within MeasurementCategories II, III, or Measurement Categories CAT I and CAT O are equivalent. These test andmeasurement circuits are for other circuits not intended for direct connection to theMAINS building installations of Measurement Categories CAT II, CAT III, orCAT Category II is for measurements performed on circuits directly connected to theelectrical distribution system. This category refers to local-level electrical distribution, such asthat provided by a standard wall outlet, for example, 115 V for or 230 V for Do not connect the NI 9224 to signals or use for measurements withinMeasurement Categories III or (UL)Class I, Division 2, Groups A, B, C, D, T4;Class I, Zone 2, AEx nA IIC T4 GcCanada (C-UL)Class I, Division 2, Groups A, B, C, D, T4; ExnA IIC T4 GcEurope (ATEX) and International (IECEx)Ex nA IIC T4 GcSafety and Hazardous Locations StandardsThis product is designed to meet the requirements of the following electrical equipment safetystandards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA No.
8 61010-1 EN 60079-0:2012, EN 60079-15:2010 IEC 60079-0: Ed 6, IEC 60079-15; Ed 410 | | NI 9224 Datasheet UL 60079-0; Ed 6, UL 60079-15; Ed 4 CSA No. 60079-0, CSA No. 60079-15 Note For UL and other safety certifications, refer to the product label or the OnlineProduct Certification CompatibilityThis product meets the requirements of the following EMC standards for electrical equipmentfor measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Industrial immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissionsNote In the United States (per FCC 47 CFR), Class A equipment is intended foruse in commercial, light-industrial, and heavy-industrial locations. In Europe,Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intendedfor use only in heavy-industrial Group 1 equipment (per CISPR 11) is any industrial, scientific, or medicalequipment that does not intentionally generate radio frequency energy for thetreatment of material or inspection/analysis For EMC declarations and certifications, and additional information, refer tothe Online Product Certification Compliance This product meets the essential requirements of applicable European Directives, as follows: 2014/35/EU; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC) 2014/34/EU; Potentially Explosive Atmospheres (ATEX)Online Product CertificationRefer to the product Declaration of Conformity (DoC) for additional regulatory complianceinformation.
9 To obtain product certifications and the DoC for this product, visit , search by model number or product line, and click the appropriate link in theCertification 9224 Datasheet | National Instruments | 11 Shock and VibrationTo meet these specifications, you must panel mount the vibrationRandom (IEC 60068-2-64)5 grms, 10 Hz to 500 HzSinusoidal (IEC 60068-2-6)5 g, 10 Hz to 500 HzOperating shock (IEC 60068-2-27)30 g, 11 ms half sine; 50 g, 3 ms half sine;18 shocks at 6 orientationsEnvironmentalRefer to the manual for the chassis you are using for more information about meeting temperature(IEC 60068-2-1, IEC 60068-2-2)-40 C to 70 CStorage temperature(IEC 60068-2-1, IEC 60068-2-2)-40 C to 85 CIngress protectionIP40 Operating humidity (IEC 60068-2-78)10% RH to 90% RH, noncondensingStorage humidity (IEC 60068-2-78)5% RH to 95% RH, noncondensingPollution Degree2 Maximum altitude5,000 mIndoor use ManagementNI is committed to designing and manufacturing products in an environmentally responsiblemanner.
10 NI recognizes that eliminating certain hazardous substances from our products isbeneficial to the environment and to NI additional environmental information, refer to the Minimize Our Environmental Impactweb page at This page contains the environmental regulations anddirectives with which NI complies, as well as other environmental information not included inthis Electrical and Electronic Equipment (WEEE)EU Customers At the end of the product life cycle, all NI products must bedisposed of according to local laws and regulations. For more information abouthow to recycle NI products in your region, visit | | NI 9224 Datasheet RoHS National Instruments (RoHS) National Instruments RoHS (For information about China RoHScompliance, go to )CalibrationYou can obtain the calibration certificate and information about calibration services for theNI 9224 at interval2 yearsNI 9224 Datasheet | National Instruments | 13 Information is subject to change without notice.