Proportional Pressure Reducing Valves - Eaton

Proportional Pressure Reducing ValvesTe chnical CatalogKBX(C)G-6-1*KBX(C)G-8-1*2 ContentsGeneral DescriptionPage 3 Typical SectionPage 3 Functional SymbolsPage 4 Model CodesPage 5 Operating DataPage 6 Performance DataPressure UnderridePage 8 Pressure DropPage 8 Pressure GainPage 9 Step ResponsePage 9 Installation DimensionsKBX(C)G-6/8 ModelsPage 10 Mounting SurfacesPage 11 XCGVM-6-10R SubplatePage 11 Electrical InformationBlock DiagramPage 12 Typical Connection ArrangementsPage 13 Further InformationPage 14 Eaton Vickers Proportional Pressure Reducing Valves V-VLPO-MC004-E May 2003 This product has been designed and tested to meet specificstandards outlined in the European ElectromagneticCompatibility Directive (EMC) 89/336/EEC, amended by91/263/EEC, 92/31/EEC and 93/68/EEC, article 5.

reduced pressure control, all models 20 bar (300 psi) Pilot control drain flow, all models 1,5 L/min (0.4 USgpm) max. ... valve Pressure transducer High pressure to port B Reduced pressure at port A Flow rate ... EATON Vickers Proportional Pressure Reducing Valves V-VLPO-MC004-E May 2003 ...

Tags:

  Control, Pressure, Eaton, Reducing, Valves, Proportional, Pressure control, Pressure valves, Proportional pressure reducing valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Proportional Pressure Reducing Valves - Eaton

1 Proportional Pressure Reducing ValvesTe chnical CatalogKBX(C)G-6-1*KBX(C)G-8-1*2 ContentsGeneral DescriptionPage 3 Typical SectionPage 3 Functional SymbolsPage 4 Model CodesPage 5 Operating DataPage 6 Performance DataPressure UnderridePage 8 Pressure DropPage 8 Pressure GainPage 9 Step ResponsePage 9 Installation DimensionsKBX(C)G-6/8 ModelsPage 10 Mounting SurfacesPage 11 XCGVM-6-10R SubplatePage 11 Electrical InformationBlock DiagramPage 12 Typical Connection ArrangementsPage 13 Further InformationPage 14 Eaton Vickers Proportional Pressure Reducing Valves V-VLPO-MC004-E May 2003 This product has been designed and tested to meet specificstandards outlined in the European ElectromagneticCompatibility Directive (EMC) 89/336/EEC, amended by91/263/EEC, 92/31/EEC and 93/68/EEC, article 5.

2 Forinstructions on installation requirements to achieve effectiveprotection levels, see this leaflet and the Installation Wiring Practices forVickers Electronic Products leaflet 2468. Wiring practices relevant to thisDirective are indicated by Electromagnetic Compatibility (EMC).3 GeneralDescriptionTypical SectionEATON Vickers Proportional Pressure Reducing Valves V-VLPO-MC004-E May 2003 These two-stage pressurereducing Valves incorporate anelectro-hydraulic proportionalpressure pilot stage by whichthe reduced Pressure setting isadjustable in response to anelectrical input. Each model isavailable in two sizes, withoptional free reverse flow bar(5000 psi)Max. reduced 330 bar(4750 psi)Max.

3 Flow L/min(80 USgpm)Mounting face to ISO 5781 (B port high Pressure inlet):For KBX(C) AG-06-2-AFor KBX(C) AH-08-2-ADesign FeaturesA maximum outlet Pressure tosuit the applicationrequirements is preset by themanual adjustment. Below thismaximum setting, the outletpressure is controlled by thesolenoid operated proportionalpilot valve, according to theelectrical command signalapplied to the normally open conditionof the mainstage allows fullflow from inlet to outlet portuntil the required reducedpressure is reached,whereupon the mainstagecloses, or reduces the flowsufficient only to maintain therequired outlet valve response ensuresthat the reduced outletpressure is unaffected by inletpressure peaks.

4 Excess build-up of outlet Pressure (duringlong holding periods, or flowback from an actuator reactingto an overload) is prevented bythe small check valve in themainstage spool, allowing fluidto bleed-off across the integral amplifier allows thepressure to be controlled froma voltage or current signalrange. The amplifier is mountedin a robust metal housing andelectrical connections are via anindustry standard 7-pin adjustments ensurehigh reproducibility valve and Benefits Remote electrical proportionalcontrol of reduced pressurefrom a choice of five pressureranges per valve size. Excellent repeatability andstable performance resultsfrom cartridge design ofmainstage parts. Low installed cost and spacerequirement from highpower/size ratios.

5 On-board Vickers Proportional Pressure Reducing Valves V-VLPO-MC004-E May 2003 Manual and ElectricalPilotsDrained to Port Y:Model code = BlankSymbol for KBXG models omit checkand internal connection Pilot Drained toPort Y; Electrical PilotDrained to Port Y1 :Model code = 3 Symbol for KBXCG models add checkvalve symbol and internalconnection plugBAY7-pin plugY1 PT5 Model CodesValve TypeKB - Proportional valve with integral amplifier, B seriesTypeX- Pressure reducerReverse Flow Check OptionBlank -OmitC-Reverse flow checkMountingG - Subplate mountedInterface - ISO 5781 With B port high Pressure inlet, A port reduced Pressure outlet6-AG-06-2-A8-AH-08-2-AManual AdjustmentK-Micrometer with keylockM-Micrometer without keylockW-Screw/locknutReduced Pressure AdjustmentBased on inlet Pressure of 350 bar(5000 psi).

6 Note, with 100 bar (1450 psi) inletthe lower limits will be 2-3 bar (30-43 psi) lower40-10-40 bar (145-580 psi)100 -12-100 bar (175-1450 psi)160 -14-160 bar (200-2300 psi)250 -15-250 bar (220-3625 psi)330 -15-330 bar (220-4750 psi)DrainBlank -Manual and electrical pilots drain to Y port3-Manual pilot drained to Y port, electrical pilot drained to Y1 portStandard FeaturesZM - for KBXE lectrical Command Options1 - +/- 10 volts control signal2- 4-20 mA control signalRamp3 - Standard ramp for KBX(C)G 6/8 valve typesCommand/ Pressure CharacteristicA -StandardElectrical ConnectionPC7 - 7 pin connector, without plug suppliedPE7 - 7 pin connector, with plug suppliedPH7 - As PE7 but with pin C used for enable signalPR7 - as PC7 but with pin C used for enable signalCoil RatingH1- 24V DC amplifier supplyDesign Number, 1* SeriesSubject to change.

7 Installationdimensions unaltered for designnumbers 10 to 19 conform to the ECElectromagneticCompatibility directive (EMC) thisKBCG valve must be fitted with ametal 7-pin plug. The screen of thecable must be securely connectedto the shell of the metal suitable IP67 rated connector isavailable from Eaton , part Alternatively a non IP67rated connector is available fromITT-Cannon, part no. CA 02 COM-E14S A7 Vickers Proportional Pressure Reducing Valves V-VLPO-MC004-E May 2003 Standard test conditions are with antiwear hydraulic oil at 36 cSt (168 SUS) and 50 C (122 F)Maximum pressures:Port B ( Pressure inlet)350 bar (5000 psi)Port A (reduced Pressure outlet)See in Model Code Port Y and side drain port Y1 2 bar (30 psi) Back Pressure at these ports is additive to the reduced Pressure setting of the flow at p = 12 bar (175 psi) and 0 mA to coil.

8 KBX(C)G-6200 L/min (53 USgpm)KBX(C)G-8300 L/min (80 USgpm) Pressure adjustment rangesSee in Model Code Minimum Pressure differential (PB-PA) for effective reduced Pressure control , all models20 bar (300 psi)Pilot control drain flow, all models1,5 L/min ( USgpm) or amplifier rating 24V x 40W max. (22 to 36V including 10% max. ripple)Command signal:Volts (see model code - 1)0 to +10V or 0 to -10 VInput impedance47 k Common mode voltage to pin B4 VCurrent (see model code - 2)4 to 20 mAInput impedance100 7-pin plug connectorPin DescriptionAPower supply positive (+)BPower supply 0V and current command returnCValve enable (PH7 & PR7)DCommand signal (+V or current in)ECommand signal (-V or current GND)FOutput monitorView of pins of fixed halfGProtective groundElectromagnetic compatibility (EMC).

9 Emission (10 V/m)EN 50081-2 Immunity (10 V/m)EN 50082-2 Monitor signal (pin F) V/amp solenoid currentOutput impedance10 k Pressure gainSee graphFactory setting - Maximum with 100% command underrideSee graphHysteresis, using Vickers drive amplifier<7%Linearity at conditions:<6% of rated pressure1. Dead-head (no flow from reduced Pressure outlet port)2. Between 10% and 100% rated pressureRepeatability< of rated pressureProtection:ElectricalReverse polarity protected EnvironmentalIEC 529, Class IP67 Operating DataFAGBCDE6 Eaton Vickers Proportional Pressure Reducing Valves V-VLPO-MC004-E May 20037710107 Mass (weight):KBXG-65,36 kg ( lb)KBXCG-65,36 kg ( lb)KBXG-86,26 kg ( lb)KBXCG-86,26 kg ( lb)Supporting products:Auxiliary electronic modules (DIN-rail mounting).

10 EHA-CON-201-A-2* Signal converterSee catalog 2410 BEHD-DSG-201-A-1* Command signal generatorSee catalog 2470 EHA-RMP-201-A-2* Ramp generatorSee catalog 2410B EHA-PID-201-A-2* PID controllerSee catalog 2427 EHA-PSU-201-A-10 Power supplySee catalog 2410 BSubplates, size 03 See catalog 2425 Mounting bolts See catalog 2314A Note: If not using Vickers recommended bolt kits, bolts must be to ISO 898 grade or attitudeNo restriction, provided that the valve is kept full offluid through port Data(continued) Eaton Vickers Proportional Pressure Reducing Valves V-VLPO-MC004-E May 2003 PerformanceDataData is typical with oil at 36 cSt (168 SUS) and at 50 C (122 F)050100150200250300350bar01000200030004 0005000psiKBX(C)G-8 KBX(C)