Example: bachelor of science

Quadruplex Aluminum Conductor 600V URD Rev Nov 2017

1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2017 Quadruplex Aluminum Conductor 600v URD The above data is nominal and subject to manufacturing tolerances. Ampacity 90 C Conductor temperatures, 20 C ambient temperature. RHO 90. 100% load factor for three Conductor triples with neutral carrying only unbalanced load. Ampacity not for NEC applications.. Application: Aluminum 600v URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90 C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can be provided pre-pulled into duct. Conductors: A concentric strand or compressed 1350-H19 series Aluminum Conductor .

1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2017 Quadruplex Aluminum Conductor 600V URD The above data is nominal and subject to manufacturing tolerances.

Tags:

  Aluminum, Conductor, 600v, Quadruplex, Quadruplex aluminum conductor 600v

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Quadruplex Aluminum Conductor 600V URD Rev Nov 2017

1 1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2017 Quadruplex Aluminum Conductor 600v URD The above data is nominal and subject to manufacturing tolerances. Ampacity 90 C Conductor temperatures, 20 C ambient temperature. RHO 90. 100% load factor for three Conductor triples with neutral carrying only unbalanced load. Ampacity not for NEC applications.. Application: Aluminum 600v URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90 C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can be provided pre-pulled into duct. Conductors: A concentric strand or compressed 1350-H19 series Aluminum Conductor .

2 Conductors are cabled together, with surface printing for identification. The neutral Conductor has a yellow stripe. Insulation: A black cross linked polyethylene (XLP) insulation. Standards: ASTM B-230 ASTM B-231 ASTM B-609 ASTM B-901 ICEA S-105-692 Federal Specification A-A595544A UL 854 RUS ACCEPTED Code Word Phase Conductor Neutral Outside Diameter (inches) Weight (lbs.) per 1000 ft. Ampacity (Amps) Neutral Size AWG Strand Insulation Thickness (mils) Size AWG Strand AWG Insulation Thickness (mils) Direct Burial In Duct Tulsa 4 7/w 60 4 7/w 60 258 119 85 Dyke 2 7/w 60 4 7/w 60 346 153 115 Wittenburg 2 7/w 60 2 7/w 60 375 153 115 Notre Dame 1/0 19/w 80 2 7/w 60 541 198 150 Syracuse 2/0 19/w 80 1 19/w 80 664 225 170 Davidson 3/0 19/w 80 3/0 19/w 80 874 250 195 Wake Forest 4/0 19/w 80 2/0 19/w 80 979 290 225 Earlham 4/0 19/w 80 4/0 19/w 80 1066 290 225 Rust 250 37/w 95 3/0 19/w 80 1203 325 245 Slippery Rock 350 37/w 95 4/0 19/w 80 1544 385 305 Wofford 500 37/w 95 350 37/w 95 2174 467 420 Windham 750 61/w 110 500 37/w 95 3147 615 492


Related search queries