Transcription of RFA - SOFIMA HYD
1 RFATANK TOP RETURN FILTER, INBUILT BREATHERRFA 1 MPa (10 bar)Port sizes: 1/2 1 Flow rates: 30 140 l/minTECHNICAL DATAMax. working pressure: 1 MPa (10 bar)Fatigue test: 0 1 MPa (10 bar) / cycles min. Bypass valve: p 170 kPa (1,7 bar) 0,1 (CD-CV-MS-RT) p 250 kPa (2,5 bar) 0,3 (FV-FD-FC)Filter element collapse pressure: p 300 kPa (3 bar) CD - CV p 1 MPa (10 bar) FD - FV - MS - RTWorking temperature: -25 +110 CMATERIALSC over: polyamideHead: aluminiumBowl: polyamideSeals: standard NBRCOMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test.
2 For further information contact our Technical mediaFilter media FCFDFVCDCVMSRTFCFDFVCDCVMSRTFC = 7 m(c)FD = 12 m(c)FV = 21 m(c)CD = 10 CV = 25 MS = 60 RT = 30 FC = 7 m(c)FD = 12 m(c)FV = 21 m(c)CD = 10 CV = 25 MS = 60 RT = 30 FCFDFVCDCVMSRTFCFDFVCDCVMSRTS ealsSeals111 = NBR Nitrile1 = NBR Nitrile11 Bypass typeBBB = 170 kPa (1,7 bar) > CD - CV - MS - RT 250 kPa (2,5 bar) > FC - FD - FVBBBPort size34-3 = 1/2 4 = 3/4 5 = 1 -45-45-45 Ports B = BSPN = NPTS = SAEBNSBNSBNSBNSTypeTypeRFACRA11021022023 0 Indicators0530P4P605 = Ports, plugged30 = Pressure gaugeP4 = Pressure switch 130 kPa (1,3 bar) - SPDTP6 = Pressure switch 200 kPa (2 bar) - SPDT0530P4P60530P4P60530P4P6 All modelsAll modelsCD - CV - RT - MSFC - FD - FVFor filter elementsAccessoriesS = Without C = With air breather, polyesterD = With air breather, metal wireSCDSCDSCDSCDA ccessoriesS = WithoutH = With dipstickSHSHSHSH11 Inorganic fiber >1000 PaperSteel wire meshInorganic fiber >1000 PaperSteel wire meshHOW TO ORDER THE COMPLETE FILTERHOW TO ORDER THE FILTER ELEMENTD3H4D1H3H2H1 49H5D2L1E1E2E4E3E31/8 1/8 RIndicator PortIndicator PortTypeRFA110 RFA210 RFA220 RFA2301/2 3/4 3/4 1 3/4 1 3/4 1 283636367510410410460 63 87 9187 9187 9150707070708383832837373777108108108243 2002653651781101752752430303021,51,51,51 622222238037037037022019024035082 88 110 115110 115110 1150,400,840,870,92D1H1E1D2H2E2D3H3E3D4H 4E4D5H5L1 RWeight KgD4M10D5 TANK MOUNTING PATTERNDIMENSIONAL LAYOUT(mm) p = 30 40 kPa (0,3 0,4 bar) for air breather element100180(0,05)(0,10)510160250 TypeC (3 )kPa(bar) pD (10 )
3 RFA110 RFA210 RFA220 RFA230(port 3/4 )(port 1 )(port 1 )(port 1 )505580115404570100606590130556085120657 0951357075120140 TypeFilter MediaFVCDCVRTMSFDCRA110 CRA210 CRA220 CRA230 TypeFilter MediaMSCV6806601004152412251500229534956 80660100415241225150022953495 RTCDS etting 130 kPa (1,3 bar)Setting 200 kPa (2 bar)NBRFKMP4P6--Pressure switchATEX 3 GD EEx e T69771/8 24 Scale 0 600 kPa (6 bar)NBRFKM30-Pressure gauge 401/8 3011 CLOGGING INDICATORSCRA110 CRA210 CRA220 CRA23018,420,734,550,611,514,921,832,2 TypeFilter MediaFD p 250 kPa(2,5 bar) p 250 kPa(2,5 bar)FV132 SPDT, 30V: > max resistive or inductive load 3A - 1A 125 or 250V: > max resistive or inductive load 3A - 0,5A respectivelyProtection IP65 - Connector DIN 43650 Technical data subject to variations without prior notice. RFA 02/2016 FLOW RATES(l/min)FLOW RATES(l/min)DIRT HOLDING CAPACITY(g) ISO MTD p = 500 kPa (5 bar)FILTER AREA(cm2)The reference fluid has a kinematic viscosity of 30 cSt and a density of 0,86 different oil viscosity please contact our Sales Department for further information.