Example: air traffic controller

SECTOR installation manual - Centurion Systems

SECTOR installation manualHIGH-VOLUMEINDUSTRIALTRAFFICBARRIE RTMCENTURION Systems (Pty) Ltd reserves the right to make changes to the products described in this manual without notice and without obligation of Centurion Systems (Pty) Ltd to notify any persons of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd makes no representations or warranties with respect to this part of this document may be copied, stored in a retrieval system or transmitted in any form or by any means electronic, mechanical, optical or photographic, without the express prior written consent of Centurion Systems (Pty) LtdSales and technical support to over 50 countries worldwide 100% testing tospecificationsIn-houseR & Ddevelopmentteam Manufacture tointernational quality standardISO 9001:2008

CENTURION SYSTEMS (Pty) Ltd reserves the right to make changes to the products described in this manual without notice and without obligation of CENTURION SYSTEMS (Pty) Ltd to notify any persons of any such revisions or changes.

Tags:

  Manual, Installation, Sector, Sector installation manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SECTOR installation manual - Centurion Systems

1 SECTOR installation manualHIGH-VOLUMEINDUSTRIALTRAFFICBARRIE RTMCENTURION Systems (Pty) Ltd reserves the right to make changes to the products described in this manual without notice and without obligation of Centurion Systems (Pty) Ltd to notify any persons of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd makes no representations or warranties with respect to this part of this document may be copied, stored in a retrieval system or transmitted in any form or by any means electronic, mechanical, optical or photographic, without the express prior written consent of Centurion Systems (Pty) LtdSales and technical support to over 50 countries worldwide 100% testing tospecificationsIn-houseR & Ddevelopmentteam Manufacture tointernational quality standardISO 9001.

2 2008 1986 199019951999 Competent after-sales technical support Centurion Systemstoday IMPORTANT SAFETY INSTRUCTIONS page 3page 1page 2page 2 Mechanical Setup Electrical Setup Commissioning and Handover 1. Declaration of conformity 2. General description Lightning protection3. Specifications Physical dimensions Technical specifications Barrier housing specifications Barrier pole specifications Fuse protection 4. Icons used in this booklet5. Product identification 6. Required tools and equipment 7. Preparation of site General considerations for the installations8.

3 Loop detectors and associated functionality FLUX OB features FLUX OB diagnostics 9. Selecting Operating Mode Simplex Mode Complex Mode PLC Mode10. Cabling requirements Simplex Mode Complex Mode (basic) Free-exit for uni-directional traffic Free-exit for bi-directional traffic11. Orientation Left hand Right hand12. Conversion from right hand to left hand Remove the coupler Fit the coupler13. SECTOR installation Enclosure positioningpage 5page 6page 6page 7page 7page 7page 8page 8page 8page 9page 10page 11page 12page 12page 13page 13page 15page 17page 17page 17page 18page 19page 19page 19page 19page 20page 21page 21page 22page 23page 24page 25page 26page 26 Concrete plinth/foundation Fitting the pole Levelling the boom pole Balancing the spring Failsafe/Lock Mode manual release14.

4 Electrical setup Connecting all wiring15. Simple Mode: Option 1 (recommended) electrical connections16. Simple Mode: Option 2 - electrical connections17. Complex Mode: Option 1 (basic) electrical connections18. Complex Mode: Option 1 (Tickect vend) electrical connections19. Free-exit loop - electrical connections20. Setting up the limits and features for the SECTOR barrier Setting up the limits21. SECTOR menu navigation 22. SECTOR controller features 23. Diagnostics Diagnostic LEDs LCD display Buzzer feedback24. Factory defaults schedule25.

5 Description of terminal functions26. Faultfinders guide Procedure A - Low battery voltage condition Procedure B - False collision detection27. Peripheral equipment28. installation handoverpage 26page 27page 28page 28page 29page 29page 30page 30page 31page 33page 35page 37page 38page 39page 39page 41page 44page 50page 50page 51page 52page 53page 55page 57page 57page 58page 59page 61 Mechanical setupHeed necessary site considerations Page 12 Check cabling requirementsPage 19 Gather required tools and equipmentPage 11 Set the concrete foundation Page 26 SECTOR enclosure positioningPage 26 Page 27 Fit the polePage 28 Page 28 These abbreviated instructions are for the experienced installer who

6 Needs a checklist to get a standard installation up and running in the minimum of installation features and functions are referred to later in this all wiring Page 30 Page 39 Page 41 Page 61step9 Electrical setupPage 2step10 Set the limits and featuresstep12 Carry out professional handover to client Commissioning and handoverstep11 Set additional features via the menus, if requiredWarnings for the installerCAREFULLY READ AND FOLLOW ALL INSTRUCTIONS before beginning to install the product. All installation , repair, and service work to this product must be carried out by a suitably qualified person Do not activate your barrier unless you can see it and can determine that its area of travel is clear of people, pets.

7 Or other obstructions NO ONE MAY CROSS THE PATH OF A MOVING BARRIER Always keep people and objects away from the barrier and its area of travel NEVER LET CHILDREN OPERATE OR PLAY WITH THE BARRIER CONTROLS Secure all easily accessed barrier controls in order to prevent unauthorized use of the barrier Do not in any way modify the components of the automated system Do not install the equipment in an explosive atmosphere: the presence of flammable gasses or fumes is a serious danger to safety Before attempting any work on the system, cut electrical power to the operator and disconnect the batteries The mains power supply of the automated system must be fitted with an all-pole switch with contact opening distance of 3mm or greater.

8 Use of a 5A thermal breaker with all-pole circuit break is recommended Make sure that an earth leakage circuit breaker with a threshold of 30mA is fitted upstream of the system Never short circuit the battery and do not try to recharge the batteries with power supply units other than that supplied with the product, or by Centurion SystemsIMPORTANTS afety InstructionsATTENTIONTo ensure the safety of people, it is important that you read all the following instructions. Incorrect installation or incorrect use of the product could cause serious harm to installer, being either professional or DIY, is the last person on the site who can ensure that the operator is safely installed, and that the whole system can be operated 3 Make sure that the earthing system is correctly constructed, and that all metal parts of the system are suitably earthed Safety devices must be fitted to the installation to guard against mechanical movement risks, such as crushing.

9 Dragging and shearing It is recommended that at least one warning indicator light be fitted to every system Always fit the warning signs visibly to the inside and outside of the barrier The installer must explain and demonstrate the manual operation of the barrier in case of an emergency, and must hand the User Guide over to the user Explain these safety instructions to all persons authorized to use this barrier, and be sure that they understand the hazards associated with automated gates Do not leave packing materials (plastic, polystyrene, etc.)

10 Within reach of children as such materials are potential sources of danger Dispose of all waste products like packaging materials, worn out batteries, etc. according to local regulations Always check the obstruction detection system, and safety devices for correct operation Centurion Systems does not accept any liability caused by improper use of the product, or for use other than that for which the automated system was intended This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the service life/operation of the product and/or be a source of dangerEverything not expressly specified in these instructions is not 51.


Related search queries