Example: stock market

STANDARD DETAILS FOR WATER MAIN …

CITY OF chicago DEPARTMENT OF WATER MANAGEMENT STANDARD DETAILS FOR WATER main INSTALLATIONS PREPARED BY: BUREAU OF ENGINEERING SERVICES April, 2009 City of chicago Department of WATER Management Richard M. Daley John F. Spatz, Jr. Mayor Commissioner This page intentionally left blank. 1 TABLE OF CONTENTS GENERAL DETAILS G-1 PROJECT SIGN G-3 SAMPLE SYBOLOGY LEGEND G-4 (1 OF 2) LEGEND - SYMBOLS G-4 (2 OF 2) LEGEND LINE STYLES WATER main DETAILS D-2 FIRE HYDRANT SETTING DETAIL D-3 FIRE HYDRANT installation DETAIL FOR VAULTED SIDEWALKS D-5 FIRE HYDRANT DRAIN DETAIL D-6 FIRE HYDRANT SUMP FOR RELOCATED HYDRANTS D-7 COLOR CODE FOR FIRE HYDRANTS D-8 WATER main TRENCH DETAILS D-9 WATER main TRENCH INSUL

city of chicago department of water management standard details for water main installations prepared by: bureau of engineering services april, 2009

Tags:

  Installation, Standards, Water, Details, Main, Chicago, Standard details for water main, Standard details for water main installations

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of STANDARD DETAILS FOR WATER MAIN …

1 CITY OF chicago DEPARTMENT OF WATER MANAGEMENT STANDARD DETAILS FOR WATER main INSTALLATIONS PREPARED BY: BUREAU OF ENGINEERING SERVICES April, 2009 City of chicago Department of WATER Management Richard M. Daley John F. Spatz, Jr. Mayor Commissioner This page intentionally left blank. 1 TABLE OF CONTENTS GENERAL DETAILS G-1 PROJECT SIGN G-3 SAMPLE SYBOLOGY LEGEND G-4 (1 OF 2) LEGEND - SYMBOLS G-4 (2 OF 2) LEGEND LINE STYLES WATER main DETAILS D-2 FIRE HYDRANT SETTING DETAIL D-3 FIRE HYDRANT installation DETAIL FOR VAULTED SIDEWALKS D-5 FIRE HYDRANT DRAIN DETAIL D-6 FIRE HYDRANT SUMP FOR RELOCATED HYDRANTS D-7 COLOR CODE FOR FIRE HYDRANTS D-8 WATER main TRENCH DETAILS D-9 WATER main TRENCH INSULATION DETAIL D-10 WATER main POLYETHYLENE WRAP DETAIL D-11 THRUST RESTRAINT CONCRETE THRUST BLOCK DETAILS D-12 THRUST RESTRAINT RESTRAINED JOINT PIPE D-13 PRECAST VALVE BASIN FOR PIPES UP TO 16-INCH

2 DIAMETER D-14 BRICK MASONRY VALVE BASIN D-16 TYPICAL 1-INCH TO 2-INCH WATER SERVICE D-18 CASING PIPE UNDER RAILROAD TRACK DETAIL D-19 (1 OF 2) WATER MAINS CROSSING OVER SEWERS AND HOUSE DRAINS D-19 (2 OF 2) WATER MAINS CROSSING UNDER SEWERS AND HOUSE DRAINS D-20 (1 OF 2) GENERAL NOTES WATER main CONTRACTS D-20 (2 OF 2) GENERAL NOTES WATER main CONTRACTS CON T D-23 NEW COPPER 1-INCH WATER SERVICE STANDARD METER VAULT D-24 NEW COPPER N. & 2 IN. WATER SERVICE STANDARD METER VAULT D-25 3 INCH, 4 INCH, 6 INCH, 8 INCH & 12 INCH METER VAULTS D-26 12 INCH METER VAULT WITH CHECK VALVE D-27 TYPICAL METER installation FOR 1 INCH WATER SERVICE WITH LAWN HYDRANT AND BACKFLOW PREVENTOR D-28 ELECTRICAL CONTINUITY BRACKET FOR TRANSITION COUPLING D-30 TYPICAL SERVICE RECONNECTION 3 INCH AND LARGER USING MJ RESILIENT WEDGE VALVE D-31 SERVICE PIPE INSULATION 2 FEEDER main DETAILS FM-1 INSPECTION MANHOLE FM-4 PITOMETER TAP BASIN PRECAST CONCRETE FM-5

3 FIRE HYDRANT SETTING 16 INCH & LARGER WATER FM-13 BUTTERFLY VALVE FM-14 TORQUE OVERLOAD PROTECTOR FM-15 BUTTERFLY VALVE BASIN PRECAST CONCRETE FM-16 (1 OF 2) BUTTERFLY VALVE BASIN MASONRY PLAN FM-16 (2 OF 2) BUTTERFLY VALVE BASIN MASONRY SECTIONAL VIEW FM-18 (1 OF 2) TYPICAL BLOW-OFF FIRE CISTERN MASONRY PLAN FM-18 (2 OF 2) TYPICAL BLOW-OFF FIRE CISTERN MASONRY SECTIONAL VIEW FM-19 TYPICAL BLOW-OFF FIRE CISTERN PRECAST CONCRETE For information about this project,please call (312) chicago TOGETHERRICHARD M.

4 DALEY, MAYORNOTES:2 -0"2 -0"CL 1/2 " PLYWOOD FOR CONSTRUCTIONSIGN MOUNTED TO STAND6"6"3 -0"4 -0"3 -0"4" x 4" WOOD POSTSANCHORED INTO GROUND AND BRACEDAS REQUIRED OR AS CALLED FOR INSPECIFICATIONS18"18"4"4"3 -0" FROM THE TIME CONSTRUCTION BEGINS TO THE TIME THAT PAVEMENT IS RESTORED." WATER " OR"SEWER" ASAPPROPRIATEDEPARTMENT OF WATERMANAGEMENT1. TWO SIGNS (ONE ON EACH END OF EACH PIPE PROJECT) MUST BE DISPLAYED2. THE LOCATION OF THE SIGN WILL BE DETERMINED FOR THE RESIDENT AFTER THE COMPLETION OF THE CONTRACT THE SIGN WILL BE PROPERTY OF THE CITY OF chicago AND MUST BE DELIVERED TO THE APPROPRIATE DISTRICT YARD UNLESS ORDERED TO DISCARD BY THE SIGNG -1 -3 SAMPLE SYMBOLOGY LEGENDNEW REDUCERNEW WEDGE VALVENEW TAPPINGCONNECTIONNEW 1/4 WATERMAIN BENDNEW 1/8 WATER main BEDNEW 1/16 WATERMAIN BEND NEW WATER main TEENEW WATER MAINCAP OR PLUGNEW FIREHYDRANTNEW WATER VALVEPROPOSED WATERMAIN TAPPROPOSED WATER

5 MAINSLEEVEPROPOSED WATERBUFFALO BOXPIPE BREAK SYMBOLNORTH ARROWHANDICAPPEDSYMBOLPROPOSED WATER MAININSPECTION MANHOLEEXIST STORMWATER CATCH BASIN EXIST STORM WATER STREETELEVATIONEXIST STORM WATERMANHOLEEXIST COMBINEDSEWER MANHOLEEXIST SANITARYSEWER MANHOLE PROPOSEDSEWER MANHOLEPROPOSED STORMWATER CATCH BASINEXIST TELEPHONE MANHOLEEXIST TELEPHONEPEDESTALEXIST TELEPHONEPOLE EXIST TREE DECIDUOUS EXIST TREE CONIFEROUSEXISTING BUSHEXIST TREESTUMPEXIST MARSH SYMBOL EXIST TRAFFIC SIGNAL MANHOLEEXIST TRAFFICSIGNALEXIST TRAFFIC SIGNT EXIST TRAFFIC CONTROL BOXEXIST ELECTRICMANHOLE EXISTING COM EDMANHOLEEXIST LIGHT POLEEXIST.

6 STREET LIGHT CONTROL BOXSEXIST CARRIAGELIGHTEXIST RAILROAD SIGNALRAILROAD TRACKPROFILERAILROADCOMMUNICATION EXIST UNKNOWN MANHOLEEXIST UTILITY POLEEXIST FLAG POLEEXIST GUY WIREFFIRE ALARM BOXGUARDRAILCONCRETE HORIZONTALTHRUST BLOCKBRIDGE COLUMNMONITORING WELLEXIST BOLLARD SOIL BORINGEXIST MAIL BOXSURVEYED CHISLEDCROSSEXIST SURVEYIRON PIPEEXIST PROPERTYCORNERSURVEY TRAVERSE POINTEXIST CONC CONCRETEMONUMENTEXIST RIGHT OFWAY MARKEREXIST CABLE CABLE GASVALVECONCRETE BLOCKEXIST GASMANHOLE NEW 1/32 WATERMAIN BENDPROPOSEDWATER METERRAMP DISABLED EXIST WATERVALVE BOXEXIST WATERBUFFALO BOXEXIST WATERMETEREXIST FIREHYDRANTEXIST STAND PIPEEXIST WATERWEDGE VALVEEXIST TAPPINGCONNECTIONEXIST 1/4 WATERMAIN BENDEXIST 1/8 WATERMAIN BENDEXIST 1/16 WATERMAIN BENDEXIST WATERMAIN TEEEXIST WATER MAINREDUCEREXIST WATERMAIN TAPEXIST WATER MAINBLOWOFFEXIST FIRECISTERNEXIST WATER MAININSPECTION MANHOLEEXIST WATER MAINPITOMETER TAP EXIST WATER main BUTTERFLY VALVE EXIST FEEDERMAIN 45 DEG BENDRESTRAINED JOINT PIPEEXISTING WATERMAIN CAP OR

7 PLUGEXISTING FLARED ENDNO. PRESSURE VALVE(RIGHT - LEFT)NO. PRESSURE VALVE(UP - DOWN)WEXIST MANHOLEWITH WATER VALVEPRESSURE GAGEPIPE RISER DOWNPIPE RISER UPEXIST 1/32 WATERMAIN BENDEXIST WATERCROSSIEXIST INSPECTIONMANHOLE- -4 LEGEND - SYMBOLSSHT. 1 OF 2 EXISTING WATER SYMBOLSPROPOSED WATER SYMBOLSSURVEY SYMBOLSRAILROAD SYMBOLSTRAFFIC SYMBOLSSEWER SYMBOLSVEGETATION SYMBOLSTELEPHONE SYMBOLSGAS SYMBOLSCABLE SYMBOLSELECTRICAL SYMBOLSMISCELLANEOUS SYMBOLSWATER SERVICESCUT-OFFEARTH HATCHCONCRETE HATCHCONCRETE HATCHGRAVEL HATCHP roposed-CurbExisting- WATER MainExisting- WATER ServicesExisting-TelephoneProposed-Sidew alkProposed- WATER MainProposed-PavementExisting-City Press ElectricalExisting-CurbExisting-FenceExi sting-SidewalkExisting-Edge of PavementAbandoned- WATER

8 MainExisting-City ElectricExisting-ComEdExisting-Hedge LineExisting-Woods Tree LineExisting ROWE xisting ROW (Vacated)Existing ROW (Elevated)Existing-EasementProposed-ROWE xisting-City Limits Boundary LineExisting- chicago Park District LineExisting-Cable TVExisting-Ditches-Creeks-Edge of WaterExisting-Embankments-Dead Ends-Retaining WallsExisting-CTA Buried Electric CablesExisting-RailroadsExisting-Steam and Cooling PipesProposed-Ditches-Creeks-Edge of WaterProposed-SewerExisting-Sediment Force MainProposed-Sediment Force MainProposed-Sewer LateralExisting-Buried StreetCar TracksExisting-SewerSYMBOLDESCRIPTIONSYM BOLDESCRIPTIONA

9 Bandoned-SewerAbandoned-GasExisting-GasS HT. 2 OF 2 -4 LEGEND - LINE STYLESP roposed-New WATER Services B-Box to PropertyProposed- WATER main (By Others)Proposed-New WATER ServicesWM to B-BoxJOINT OF SIDEWALKSTONE ABOVE TO COMEOVER CENTER OF WALLBLOCKINGCONCRETEPIERBRICK OR CONCRETE WALLWATERPROOFINGSIDEWALKCURBPAVEMENTBLO CKINGTO BE FILLED WITH SANDAFTER HYDRANT IS SETCURBABOVEWATERPROOFINGWATERPROOFINGPI ERSECTION VIEW 1/4 " EXPANSION JOINTFILL WITH TAR8"PLAN VIEW REINFORCED CONCRETESUPPORT BRACKET(S)TO SUIT CONDITIONS1" FLEXIBLE COPPERTUBING TO DRAIN2 OR ROADWAYS 6 -9" 3 -6" 8" 3 -6" 8" 3 -6" 8" 8" 1" SOFT COPPER WATERSERVICE TUBING TO STANDARD HYDRANT installation DETAILFOR VAULTED SIDEWALKSD -3 THIS DETAIL IS PROVIDED FORREFERENCE PURPOSES ONLYAND IS NOT A main STANDARDPROP.

10 CURB & GUTTEREXIST. CURB & GUTTERPROP. CURB & GUTTERAASEE TILE DRAIN DETAILVIEW "A-A"1 1/2 4 x 4 x 3 SUMP 6" 6" MECHANICAL JOINTIF TRANSITION SLEEVE REQ DPROVIDE CONCRETE THRUSTBLOCK ON HYDRANTNOTE: WATER TABLE MUST BE BELOWBOTTOM OF DRAIN -0" CITY ROADWAYS2 -6" ROADWAYS3" OFBITUMINOUSCONCRETE 3/4 "STRAIGHTMETER COUPLINGHYDRANTBRANCHEXIST. CURB& GUTTE


Related search queries