Transcription of TD 200 Operator Interface - Siemens
1 Preface, ContentsProduct Overview and Installation1 Configuring the TD 2002 Operating the TD 2003 Creating Sample Programs4 AppendicesSpecifications and ReferenceAMultiple CPU ConfigurationsBTroubleshootingCTD 200 Parameters and MessagesDIndex10/99 Edition 5TD 200 Operator InterfaceUser ManualThis manual has the order number:6ES7272-0AA00-8BA0 SIMATICThis manual contains notices which you should observe to ensure your own personal safety, aswell as to protect the product and connected equipment. These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger:!Dangerindicates that death, severe personal injury or substantial property damage will result if properprecautions are not taken.!Warningindicates that death, severe personal injury or substantial property damage can result if properprecautions are not taken.!Cautionindicates that minor personal injury or property damage can result if proper precautions are your attention to particularly important information on the product, handling the product,or to a particular part of the qualified personnel should be allowed to install and work on this equipment.
2 Qualifiedpersons are defined as persons who are authorized to commission, to ground, and to tag circuits,equipment, and systems in accordance with established safety practices and the following:!WarningThis device and its components may only be used for the applications described in the catalog orthe technical description, and only in connection with devices or components from other manufacturers which have been approved or recommended by product can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as , SIMATIC NET and SIMATIC HMI are registered trademarks of Siemens parties using for their own purposes any other names in this document which refer to trade-marks might infringe upon the rights of the trademark have checked the contents of this manual for agreement with thehardware and software described. Since deviations cannot be pre-cluded entirely, we cannot guarantee full agreement. However, thedata in this manual are reviewed regularly and any necessary cor-rections included in subsequent editions.
3 Suggestions for improve-ment are of LiabilityCopyright Siemens AG 1995 All rights reservedThe reproduction, transmission or use of this document or itscontents is not permitted without express written will be liable for damages. All rights, including rightscreated by patent grant or registration of a utility model or design, AGBereich Automatisierungs- und AntriebstechnikGeschaeftsgebiet Industrie-AutomatisierungssystemePostfac h 4848, D- 90327 Nuernberg Siemens AG 1995 Subject to technical Aktiengesellschaft6ES7272-0AA00-8BA0 Notes on SafetyQualified PersonnelCorrect UsageTrademarksiiiSIMATIC TD 200 Operator InterfaceC79000-G7076-C205-05 PrefacePurposeThe SIMATIC TD 200 Operator Interface User Manual is a combination user andreference manual that describes the operation of the TD 200 Operator InterfaceModule with an S7-200 programmable logic manual is designed for engineers, programmers, and maintenance personnelwho have a general knowledge of programmable logic controllers and of This ManualThis manual describes the operation of version and later of the TD 200.
4 Thisrelease includes new features and other operational NotesVersion of the TD 200 includes the following new features:SSupports real (floating-point) numbersSProvides password protection for editable variables and for the Menu mode ofoperationSSupports multiple parameter blocks in a single S7-200 CPU (with a setup menufor entering the V memory address)SSupports Kbaud communication rate (with a setup menu for changing thebaud rate)SSets a bit in the parameter block every time an arrow key is pressed, thusallowing your program to have more control of the TD 200 SIncludes an alternative character set for creating bar chartsOther enhancements (such as using any key-not just the ESC key-to cancel thescrolling of the messages, or using SHIFT-ENTER to set a variable to 0) eitherimprove the performance of the TD 200 or make it easier to use. For example, youcan now use the SHIFT-UP/DOWN arrow keys to perform acharacter-by-character edit of a variable that is embedded in a of the TD 200 includes the following new features:SCorrects problems with multi-master networksSMakes the editors more consistentFor upgrades to version of the TD 200, contact your TD 200 Operator InterfaceC79000-G7076-C205-05 Agency ApprovalsThe SIMATIC S7-200 series meets the standards and regulations of the Laboratories, Inc.
5 : UL 508 Listed (Industrial Control Equipment)SCanadian Standards Association: CSA Number 142 Certified (Process Control Equipment)SEuropean Community EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EECHow to Use This ManualIf this is your first experience using an Operator Interface , read the entire manual. Ifyou are an experienced user, refer to the Table of Contents or Index to find InformationRefer to the following documentation for more detailed information about selectedtopics:SSIMATIC S7-200 Programmable Controller System Manual: providesinformation about installing and programming the S7-200 Micro PLCs, includingthe following topics: Installing and wiring the S7-200 CPU and expansion I/O modules, andinstalling the STEP 7-Micro/WIN software Designing and entering a program Understanding features of the CPU, such as data types and addressingmodes, the CPU scan cycle, password-protection, and networkcommunicationThis manual also includes descriptions and examples for the programminginstructions, typical execution times for the instructions, and the data sheets forthe S7-200 STEP 7-Micro/DOS User Manual.
6 Describes how to use theSTEP 7-Micro/DOS programming software package for the SIMATIC S7-200series of programmable logic TD 200 Operator InterfaceC79000-G7076-C205-05 SIMATIC Customer Support HotlineOpen round the clock, worldwide:Johnson CityNurembergSingaporeSIMATIC HotlineNurembergSIMATIC BASIC HotlineJohnson CitySIMATIC BASIC HotlineSingaporeSIMATIC BASIC HotlineLocal time: 7:00 to 17:00 Phone:+49 (911) 895-7000 Fax:+49 (911) time: 8:00 to 17:00 Phone:+1 423 461-2522 Fax:+1 423 5:00 Local time: 8:30 to 17:30 Phone:+65 740-7000 Fax:+65 Authorization HotlineLocal time: 7:00 to 17:00 Phone:+49 (911) 895-7200 Fax:+49 (911) Hotline(fee based, only withSIMATIC Card)Local time: 0:00 to 24:00 Phone:+49 (911) 895-7777 Fax:+49 (911) 895-7001 GMT:+01:00 The languages of the SIMATIC Hotlines are generally German and English, in addition, French, Italian and Spanish arespoken on the authorization TD 200 Operator InterfaceC79000-G7076-C205-05 SIMATIC Customer Support Online ServicesThe SIMATIC Customer Support team offers you substantial additional informationabout SIMATIC products via its online services:SGeneral current information can be obtained from: the Internet under product information leaflets and downloads which you may find usefulare available: the Internet under unter via the Bulletin Board System (BBS) in Nuremberg (SIMATIC CustomerSupport Mailbox) under the number +49 (911) access the mailbox, use a modem with up to ( Kbps) withparameters set as follows: 8, N, 1, ANSI; or dial in via ISDN ( , 64 Kbps).
7 PrefaceviiSIMATIC TD 200 Operator InterfaceC79000-G7076-C205-05 ContentsPrefaceiii.. 1 Product Overview and Installation1-1.. Features1-2.. the TD 2001-4.. the Communication Cable1-6.. a Power Cable1-7.. the Device1-7.. 2 Configuring the TD 2002-1.. the STEP 7-Micro/WIN TD 200 Configuration Wizard2-2.. a Sample Program2-20.. 3 Operating the TD 2003-1.. the Display Message Mode3-2.. the Menu Mode3-5.. Messages3-6.. CPU Status Menu3-7.. I/O3-9.. Time and Date in the CPU3-13.. the Password3-15.. the TD 200 Setup Menu Option3-16.. 4 Creating Sample Programs4-1.. a Text Message to Create a Clock for a CPU 2144-2.. the Bar Graph Character Set4-5.. ASpecifications and ReferenceA-1.. , Directives and DeclarationsA-2.. Specifications for Model Number 6ES7 272-0AA00-0YA0A-4.. CharactersA-7.. Key Combinations for International and Special CharactersA-8.. viiiSIMATIC TD 200 Operator InterfaceC79000-G7076-C205-05 BMultiple CPU ConfigurationsB-1.. for Multiple CPU CommunicationB-2.
8 A TD/CPU CableB-4.. CTroubleshootingC-1.. DTD 200 Parameters and MessagesD-1.. 200 Parameter BlockD-2.. the Parameter BlockD-4.. MessagesD-9.. Data Values in a Text MessageD-11.. Message TypesD-20.. Variables with the TD 200D-22.. IndexIndex-1.. Contents1-1 SIMATIC TD 200 Operator InterfaceC79000-G7076-C205-05 Product Overview and InstallationThe Text Display 200 (TD 200) is a text display and Operator Interface for theS7-200 family of programmable logic controllers. This manual uses the termsprogrammable logic controller and S7-200 CPU (or CPU) interchangeably. The following is a list of TD 200 features:SDisplays messages read from the S7-200 adjustment of designated program ability to force/unforce I/O ability to set the time and date for CPUs that have real-time TD 200 receives its power either from the S7-200 CPU through the TD/CPUcable or from a separate power TD 200 functions as a point-to-point Interface (PPI) master when it isconnected to one or more S7-200 CPUs.
9 The TD 200 is also designed to operatewith any other PPI master in a network. Multiple TD 200s can be used with one ormore S7-200 CPUs connected to the same manual provides you with hardware configuration directions and programmingexamples that require additional equipment. The following is a list of additionalequipment that is necessary to set up and use your TD 200:SS7-200 series programmable logic controllerSS7-200 programming deviceSProgramming cable appropriate for your programming deviceChapter the TD the Communication a Power Cable1-711-2 SIMATIC TD 200 Operator FeaturesComponents of the TD 200 The TD 200 is a small, compact device that provides all the necessarycomponents for interfacing with your S7-200 CPU. Figure 1-1 shows the majorcomponents of the TD 200. These components are described in Table 1-1. Forfurther information on the technical specifications of the TD 200, see Appendix A. Text Display AreaUser LabelSIEMENSTD 200F1F F F F F F F F E EN E TD/CPU CablePowerConnectionCommunicationPortGas ketSpacersFigure 1-1 Major Components of the TD 200 Table 1-1 Components of the TD 200 ComponentDescriptionText Display AreaThe text display area is a backlit liquid crystal display (LCD) withtwo 20-character lines.
10 It allows you to see messages receivedfrom the S7-200 gasket is provided with the TD 200 for installation in PortThe communication port is a 9-pin D-connector that allows you toconnect the TD 200 to an S7-200 CPU using the suppliedTD/CPU ConnectionYou can connect an external power supply to the TD 200 throughthe power connection access located on the right side of theTD 200. This connection is not required when you use theTD/CPU CableThe TD/CPU cable provides communication and power to yourTD 200. It is a 9-pin, straight-through cable that is supplied withyour TD LabelThe user label is a pull-out label that you can use to customizethe function key labels for your Overview and Installation1-3 SIMATIC TD 200 Operator InterfaceC79000-G7076-C205-05 Table 1-1 Components of the TD 200 ComponentDescriptionKeysThe TD 200 has nine keys. Five of these keys providepredefined, context-sensitive functions, and four keys provideuser-defined spacers are included for mounting the TD 200 to amounting surface.