Example: bankruptcy

USB-6000 Specifications - National Instruments

SPECIFICATIONSUSB-60008 AI (10 kS/s), 4 DIO USB Multifunction I/O DeviceDefinitionsWarranted Specifications describe the performance of a model under stated operatingconditions and are covered by the model following characteristic Specifications describe values that are relevant to the use of themodel under stated operating conditions but are not covered by the model warranty. Typical Specifications describe the performance met by a majority of models. Nominal Specifications describe an attribute that is based on design, conformance testing,or supplemental are Typical unless otherwise are valid at 25 C unless otherwise InputNumber of analog inputs8, single-endedInput resolution12 bitsMaximum sample rate (aggregate),system-dependent10 kS/sConverter typeSuccessive approximationAI FIFO2,047 samplesTiming resolut

Caution Do not leave a voltage above 3.3 V connected on any DIO line when the device is powered off. This may lead to long term reliability issues. Minimum VIH 2.4 V Maximum VIL 0.8 V Maximum input leakage current At 3.3 V 0.8 mA At 5 V 4.5 mA

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of USB-6000 Specifications - National Instruments

1 SPECIFICATIONSUSB-60008 AI (10 kS/s), 4 DIO USB Multifunction I/O DeviceDefinitionsWarranted Specifications describe the performance of a model under stated operatingconditions and are covered by the model following characteristic Specifications describe values that are relevant to the use of themodel under stated operating conditions but are not covered by the model warranty. Typical Specifications describe the performance met by a majority of models. Nominal Specifications describe an attribute that is based on design, conformance testing,or supplemental are Typical unless otherwise are valid at 25 C unless otherwise InputNumber of analog inputs8, single-endedInput resolution12 bitsMaximum sample rate (aggregate),system-dependent10 kS/sConverter typeSuccessive approximationAI FIFO2,047 samplesTiming resolution125 ns (8 MHz timebase)

2 Timing accuracy100 ppm of actual sample rateInput range 10 VWorking voltage 10 VInput impedance>1 M Overvoltage protection 30 VTrigger sourcesSoftware, PFI 1 System noise110 mVrmsAbsolute accuracy at full scale, single-endedTypical at 25 C26 mVMaximum over temperature135 mVNote Absolute accuracy at full scale on the analog input channels is determinedusing the following assumptions: Number of readings = 100, Coverage factor = 3 .Digital I/ONumber of digital 0 Static digital I/O or counter 1 Static digital I/O or AI Start digital digital I/ODirection controlEach channel individually programmable asinput or outputOutput driver typeEach channel individually programmable asopen collector or active driveAbsolute maximum voltage range0 V to 5 V with respect to D GNDPull-down k to D GNDP ower-on stateInputDigital InputInput voltage rangePowered on0 V to 5 VPowered off0 V to VInput voltage protection 20 V.

3 For up to 24 hours1 System noise measured at maximum sample | | USB-6000 SpecificationsCaution Do not leave a voltage above V connected on any DIO line when thedevice is powered off. This may lead to long term reliability VMaximum VMaximum input leakage currentAt mAAt 5 mADigital Output (Active Drive)Maximum VOLAt 4 VAt 1 VMinimum VOHAt 4 VAt 1 VMaximum VMaximum output current per line 4 mADigital Output (Open Collector)Maximum VOLAt 4 VAt 1 VMinimum VOHD ependent on user provided pull-up resistorand pull-up voltageMaximum output (sinking)

4 Current per line-4 mAMaximum pull-up voltage5 VMaximum leakage currentAt mAAt 5 mACounterNumber of counters1 Resolution32 bitsCounter measurementsEdge counting, rising or fallingUSB-6000 Specifications | National Instruments | 3 Counter directionCount upCounter sourcePFI 0 Maximum input frequency5 MHzMinimum high pulse width100 nsMinimum low pulse width100 nsBus InterfaceUSB specificationUSB Full SpeedUSB bus speed12 Mb/sPower RequirementsFrom USB, VDC to VDC150 mA maximumNote A typical bus-powered hub provides 100 mA on its USB lines.

5 TheUSB-6000 does not work on a bus-powered CharacteristicsDimensionsWithout screw terminal mm mm mm( in. in. in.)With screw terminal connector mm mm mm( in. in. in.)4 | | USB-6000 SpecificationsFigure 1. USB-6000 mm( in.) mm( in.) mm( in.) mm( in.)07406531223AI ( 10V) / PFI xxWeightWithout screw terminal connectorplug73 g ( oz)With screw terminal connector plug84 g (3 oz)USB connectorUSB Micro-B receptacle (1)I/O connectorType16-position screw terminal plug (1)Screw-terminal mm2 to mm2 (16 AWG to 28 AWG)Torque for screw N m to N m ( lb.)

6 In. lb. in.)If you need to clean the module, wipe it with a dry VoltagesConnect only voltages that are within these 30 V max, Measurement Category IMeasurement Category I is for measurements performed on circuits not directly connected tothe electrical distribution system referred to as MAINS voltage. MAINS is a hazardous liveelectrical supply system that powers equipment. This category is for measurements of voltagesUSB-6000 Specifications | National Instruments | 5from specially protected secondary circuits. Such voltage measurements include signal levels,special equipment, limited-energy parts of equipment, circuits powered by regulatedlow-voltage sources, and electronicsCaution Do not use this module for connection to signals or for measurementswithin Measurement Categories II, III, or IVNote Measurement Categories CAT I and CAT O (Other) are equivalent.

7 These testand measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT (IEC 60068-2-1 and IEC 60068-2-2)Operating0 C to 40 CStorage-40 C to 85 CHumidity (IEC 60068-2-56)Operating5% to 90% RH, noncondensingStorage5% to 95% RH, noncondensingPollution Degree (IEC 60664)2 Maximum altitude2,000 mIndoor use product is designed to meet the requirements of the following electrical equipment safetystandards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA No.

8 61010-1 Note For UL and other safety certifications, refer to the product label or the OnlineProduct Certification CompatibilityThis product meets the requirements of the following EMC standards for electrical equipmentfor measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions EN 55022 (CISPR 22): Class A emissions EN 55024 (CISPR 24): Immunity6 | | USB-6000 Specifications AS/NZS CISPR 11: Group 1, Class A emissions AS/NZS CISPR 22: Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissionsNote In the United States (per FCC 47 CFR), Class A equipment is intended foruse in commercial, light-industrial, and heavy-industrial locations.

9 In Europe,Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intendedfor use only in heavy-industrial Group 1 equipment (per CISPR 11) is any industrial, scientific, or medicalequipment that does not intentionally generate radio frequency energy for thetreatment of material or inspection/analysis For EMC declarations and certifications, and additional information, refer tothe Online Product Certification Compliance This product meets the essential requirements of applicable European Directives, as follows: 2014/35/EU; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC)Online Product CertificationRefer to the product Declaration of Conformity (DoC) for additional regulatory complianceinformation.

10 To obtain product certifications and the DoC for this product, visit , search by model number or product line, and click the appropriate link in theCertification ManagementNI is committed to designing and manufacturing products in an environmentally responsiblemanner. NI recognizes that eliminating certain hazardous substances from our products isbeneficial to the environment and to NI additional environmental information, refer to the Minimize Our Environmental Impactweb page at This page contains the environmental regulations anddirectives with which NI complies, as well as other environmental information not included inthis Specifications | National Instruments | 7 Waste Electrical and Electronic Equipment (WEEE)