Search results with tag "Oscilloscopes"
A621 A622 Current Probes Datasheet - Tektronix
download.tek.comdigital multimeters, TekMeter, and oscilloscopes. The A622 can measure AC/DC currents from 50 mA to 100 A peak over a frequency range of DC to 100 kHz. It provides 10 mV or 100 mV output for each Amp measured. Recommended products TPS2000, TDS1000B, TDS2000C, and TDS3000C Series oscilloscopes and DMM4020 1, DMM4040 1, and DMM4050 1 digital ...
Laboratory/Research Skills for Science Resume
www.memphis.eduOscilloscopes Blood gas analyzer Microtomes: paraffin, celloidin X-ray equipment Other Skills or Relevant Experience Data processing Laboratory Statistical analysis Programming skills Database skills Computer languages (HTML, C++, etc.) Light microscopy, fluorescence microscopy, and scanning electron microscopy
LDO PSRR Measurement Simplified (Rev. A)
www.ti.comoscilloscopes can measure down to the millivolt range, the maximum range of PSRR that could realistically be measured using an oscilloscope is about 40dB–50dB. Using the TPS78101EVM from Texas Instruments, the PSRR is measured using signal generator and oscilloscope. The input and output waveforms are as shown in Figure 5:
Infiniium V-Series Oscilloscopes - Keysight
www.keysight.comMay 11, 2021 · − InfiniiMode feature allows differential, single-ended and common mode measurements without probe reconnection − First magnetically engaged probe for secure connection − Lowest-noise active voltage termination adapter − Industry’s only bandwidth upgradable probes Keysight’s proprietary and custom front-end
オシロスコープのすべて - Tektronix
download.tek.com4 www.tektronix.com/ja/oscilloscopes 入門書 光電池 光源 図1 . .オシロスコープを使用した科学データ収集の例 はじめに 海の波 ...
Electrician CV example - DayJob.com
www.dayjob.com& testing equipment including oscilloscopes, ammeters & test lamps. Administrative work like maintaining records and files and preparing reports. orking on ladders, scaffolds, and roofs in retail outlets, pubs, local authorities and general commercial office buildings. KEY SKILLS AND COMPETENCIES
オシロスコープのすべて - Tektronix
download.tek.com4 www.tektronix.com/ja/oscilloscopes 入門書 光電池 光源 図1 . .オシロスコープを使用した科学データ収集の例 はじめに 海の波 ...
AC CIRCUITS: RLC SERIES CIRCUIT INTRODUCTION
www.austincc.eduJul 11, 2007 · The Oscilloscope We will be using both Channel 1 and Channel 2 on the oscilloscope. Channel 1 will measure the voltage across the resistor (VR) in your circuit. Channel 2 will measure the input voltage from the Function Generator, Vg , (point “a” ). The oscilloscope will be triggered by the signal on Channel 1.
Basic electronics circuits - Festo Didactic
www.festo-didactic.com• Fundamentals of alternating current technology • Fundamentals of semiconductors ... oscilloscope and safety laboratory cables is required for setting up and evaluating the circuits. The circuits for all 10 exercises covering basic electronic …
Sensorless Field Oriented Control (FOC) of a Permanent ...
ww1.microchip.comJan 05, 2010 · variables on an oscilloscope. This feature facilitates control loop adjustment. Note: The characteristics of the DMCI tool are subject to change. This description of the DMCI tool is accurate at the date of publication.
ELECTRON SPIN RESONANCE (ESR) SPECTROSCOPY
www.nou.ac.in24 1 34 2.0023 9.274 10 0.34 ... Experiment, it is the magnetic component of the electromagnetic radiation that interacts ... A suitable oscilloscope or recorder. Klysteron Preamplifier Phase sensitive detector Recorder Modulator Dummy load Crystal detector Microwave bridge cavity N S
EXPERIMENT #1 STUDY OF RC AND RL CIRCUITS
www.iium.edu.my27mH and C=1uF, oscilloscope and square-wave generator. Set up the RLC circuit as shown in Figure 1 Figure 1 Apply a 4.0 V (peak-to-peak) sinusoidal wave as input voltage to the circuit. Set the Source on Channel A of the oscilloscope, and the voltage across the ca[pcitance on Channel B of the oscilloscope.
Experiment 4: Amplitude Modulation - University of Texas ...
personal.utdallas.eduIn Experiment 3, DSB signals were generated by the multiplication of a message signal with a carrier waveform. This resulted in the translation of the message spectrum to the carrier frequency location. ... oscilloscope to the output of the modulator (at pin 7). 2. Turn the power supply on and capture the AM signal and its spectrum by executing ...
Experiment 2: Oscillation and Damping in the LRC Circuit
courses.physics.ucsd.eduExperiment 2: Oscillation and Damping in the LRC Circuit 1 Experiment 2: Oscillation and Damping in the LRC Circuit Introduction In this laboratory you will construct an LRC series circuit and apply a constant voltage over it. You will view the voltage drop over the various elements of the circuit with the oscilloscope. You must
12. Transformers, Impedance Matching and Maximum Power ...
www.hunter.cuny.eduThe Use of a Transformer to Isolate a Circuit from Ground Consider a RLC circuit indicated below: The signal generator output has a ground as indicated above. This also grounds one side of the inductor L inadvertently. If you use an oscilloscope to …
Experiment #1: RC Circuits - University of California, San ...
courses.physics.ucsd.eduSpecifically you will use the multimeter and oscilloscope during this lab. Recall that the oscilloscope must be calibrated at the beginning of any experiment in which it is used. 1 Physics 1.1 Electrical Circuit Definitions Any section of a circuit that is at constant voltage is called a “node.” An example is a piece of wire
TwinCAT 3: the flexible software solution for PC-based control
download.beckhoff.cominto software full usability of the PC performance enhancements for the control technology availability of familiar PC interfaces: Ethernet, USB, DisplayPort, etc. ... additional functionalities such as a software oscilloscope. The TwinCAT 3 automation software consists of an engineering and a runtime component.
Introduction to comparators, their parameters and basic ...
www.st.comIntroduction to comparators, their parameters and basic applications By Radim Smat ... Use passive oscilloscope probes with 10:1 dividing ratio. For increased accuracy on V IO reading and decreased noise background, the probe applied at VIN can be replaced by a coaxial cable.
ELECTRICAL ENGINEERING LABORATORY I - Clemson …
www.clemson.eduRewrote laboratory sessions on SPICE and Oscilloscope. Added equipment list and references. Created common Appendix (A to E) for ECE 309 and ECE 212. Moved Safety and Oscilloscope background information into Appendix. Added appendix for Tektronix TDS 1002B Oscilloscope. August 2008. 2010 Author: Dr. J. E. Harriss.
BASICS OF THE SPECTRUM ANALYZER
web.ece.ucsb.edubasic ideas. Given a voltage signal x(t), we need to somehow extract the frequency content out of it. As we know, the digital storage oscilloscope provides one solution as it can calculate the FFT of the signal from stored samples. Another solution would be to …
PC Oscilloscope Software User's Guide - Pico Technology
www.picotech.comWelcome to PicoScope 6, the PC Oscilloscope software from Pico Technology. This user's guide is designed to help you use both versions of the software: PicoScope 6, for test and measurement users and PicoScope 6 Automotive, for vehicle diagnostics users. With a scope device from Pico Technology, PicoScope turns your PC into a powerful PC
12 THINGS TO CONSIDER WHEN CHOOSING AN …
www.mouser.comdifferential active probes 20 GHz or more. Adding a current Probe enables the scope to calculate and display instantaneous power, true power, apparent power, and phase. High voltage probes measure to 40 kv peak. Specialty probes include logic, optical and environmental types. 10 12 THINGS TO CONSIDER WHEN CHOOSING AN OSCILLOSCOPE
ELECTRICAL AND ELECTRONICS ENGINEERING
www.karunya.eduammeter, multi-meter, oscilloscope. Real-life resistors, capacitors and inductors. 2. Measuring the steady-state and transient time response of R L, ... To impart knowledge on the principles of digital electronics and fundamentals of electron devices. Course Outcome At the end of the course, the student will be able to
Understanding FFTs and Windowing - NI
download.ni.comThis tutorial is part of the Instrument Fundamentals series. Contents wwUnderstanding the Time Domain, Frequency Domain, and FFT a. All Signals Are the Sum of Sines b. Deconstructing Signals Using the FFT ... view the output signal on the oscilloscope in the time domain in Figure 8 below. It looks pretty good! However, when you view the signal ...
IDSUserManual ENG v1.0
www.fordservicecontent.comOscilloscope, Digital Multi‐Meter, Ignition System Test, Fuel System Test, and SGM. NOTE: The software application will detect the interface device that is connected to the PC. Indicator icons will appear at the bottom right‐hand corner of the IDS …
Reducing noise on the output of a switching regulator
www.ti.comcapacitance of the inductor (the oscilloscope must have enough bandwidth to capture this, typically ≥200 MHz). HF noise can be very harmful to systems with sensitive signal chains. All integrated circuits (ICs) have a power-supply rejection ratio (PSRR) that enables the V CC pin to reject a certain amount of noise coming from that power rail.
33120A Function/Arbitrary Waveform Generator - Keysight
www.keysight.comNov 12, 2019 · Link the Keysight 33120A to your PC The included Keysight IntuiLink software allows you to easily create, edit, and download complex waveforms using the IntuiLink Arbitrary Waveform Editor. Or you can capture a waveform using IntuiLink Oscilloscope or DMM and send it to the 33120A for output. For programmers, ActiveX components can
Chapter 1.1 A Brief History of Video Games
www.sci.brooklyn.cuny.edu2 The First Video Games William Higginbotham and Tennis for Two Created in 1958 for the Brookhaven National Laboratory’s annual visitor day Display was an oscilloscope Sound effects were a side-effect of the relays that made the game run No one realized its significance
OSCILLOSCOPE INSTRUCTION MANUAL
d17bck4wpaw2mg.cloudfront.netTable Of Contents: Test Instrument Safety General Notice Before Operation Operating Instructions Application ... Test Instrument Safety OSCILLOSCOPE INSTRUCTION MANUAL WARNING 1. Don't expose high voltage needlessly in the equipment under test. Remove ... 1-2-5 sequence, 10 step with variable control. ...
GUIDE FOR THE USER - Hantek
hantek.comClick the software icon on the desk after you finished the software setting and equipment connecting. Then a user interface will be showed as follows: In addition to displaying waveforms, the display area is filled with many details about the waveform and the oscilloscope control settings. 1. The Main Menu All settings can be found in the main ...
5 Series B MSO - download.tek.com
download.tek.comThe 5 Series MSO redefines what a Mixed Signal Oscilloscope (MSO) should be. FlexChannel technology enables each channel input to be used as a single analog channel, eight digital logic inputs (with the TLP058 logic probe), or simultaneous analog and spectrum views with independent acquisition controls for each domain. Imagine the flexibility
Introduction to Oscilloscope Probes: Lab Experiment
www.physics.wisc.edu1. Understand the basic characteristics of an oscilloscope probe. 2. Describe the different types of probes and their uses. 3. Learn how to connect probes to various test points in a circuit. 4. Learn how probes can affect the quality of electronic measurements. Equipment List 1. One Tektronix MSO2000 or DPO2000 Series digital oscilloscope. 2.
TP N° 2 UTILISATION DE L’OSCILLOSCOPE - Technologue Pro
www.technologuepro.comTravaux Pratiques Mesures Electriques ISET de Kélibia Narjess SGHAIER & Fèdia DOUIRI 7 TP N° 2 UTILISATION DE L’OSCILLOSCOPE OBJECTIF Se familiariser avec l’oscilloscope, et pratiquer ses multiples utilisations.
L’oscilloscope - Université Laval
w3.gel.ulaval.caGEL-16132 Circuits L’oscilloscope 6 1) Mise sous tension et réglage du faisceau d’électrons Sur l’oscilloscope Tektronix 2255, la mise sous tension de l’appareil s’effectue à l’aide du bouton Power. D’autres modèles ne comportent pas nécessairement un bouton de mise sous tension spécifique. Il faut agir sur le bouton
B1500A Semiconductor Device Analyzer - Keysight
www.keysight.comDec 26, 2019 · Keysight EasyEXPERT group+ GUI based characterization software is available either on the B1500A’s embedded Windows 10 platform with 15inch touch screen or on your PC to accelerate the - ... • Oscilloscope view (voltage/current waveform viewer) is supported
Microsquirt Hardware Manual - EFI Source
www.efisource.comOscilloscope or scope-meter or soundcard scope Test light Power probe 1.3 How to use this manual Customers new to EFI are advised to read all of sections 1-5 as these cover some fundamental concepts and give an overview of how to connect up the various EFI components. More experienced customers can likely skim through sections 1-5.
DSO138 Oscilloscope Kit & Manual - Z-100 LifeLine Home
z100lifeline.swvagts.comJan 07, 2021 · DSO138 Oscilloscope Kit & Manual By Steven Vagts Z-100 LifeLine Insert, Issue #133 Updated January 7, 2021 DSO138 Oscilloscope Kit Description: The DSO138 Oscilloscope is an inexpensive low-speed miniature oscilloscope with 2.4"
AN2686 Ethernet Compliance Testing for 10BASE-T, …
ww1.microchip.coma waveform generator to the test board. The differential signal is fed back to the oscilloscope running the return loss measurements. Two oscilloscope channel probes are attached to the pair A jumpers for return loss measurement. For the calibrations for short, open, and load, use the same type of Ethernet cable (straight or crossover) for measure-
BAS16 series High-speed switching diodes - Nexperia
assets.nexperia.comOscilloscope: rise time tr =0.35ns Fig 5. Reverse recovery time test circuit and waveforms Input signal: forward pulse rise time tr = 20 ns; forward current pulse duration tp 100 ns; duty cycle 0.005 Fig 6. Forward recovery voltage test circuit and waveforms trr (1) + IF t output signal tr tp t 10 % 90 % VR input signal V = VR + IF × iRS RS ...
HDS200 Dual Channel Series Handheld Oscilloscope User ...
files.owon.com.cnattached to the oscilloscope or accessories suitable for oscilloscope instrument series products specified by our company shall be used. ⚫ Before use, check the multimeter test probe, oscilloscope probe and accessories for mechanical damage. If damage available, replace it. ⚫ Remove all unused multimeter test probes, oscilloscope probes and
PID CONTROLLER DESIGN FOR CONTROLLING DC MOTOR …
umpir.ump.edu.myexperiment, the result performance of the PID controller is compared in term of ... 3.2.1.2 Installation Guide 29 3.3 Real Time Computing 31 ... 3.5 Oscilloscope 16 3.6 Data Acquisition Card (PCI-1710HG) 16 3.7 Industrial Wiring Terminal Board with CJC Circuit 17 ...
SCR Power TheorySCR Power Theory Training Manual Training ...
www.chromalox.comAn oscilloscope is a device that allows you to take a snapshot of alternating current. If an oscilloscope were connected to a 120 VAC household outlet, the resultant sinusoidal waveform viewed would be as shown in Figure 1. An AC waveform is comprised of positive half cycles and negative half cycles. The point in which the
BAT54HT1 - Schottky Barrier Diodes
www.onsemi.comSampling Oscilloscope tr tp t 10% 90% IF IR trr t iR(REC) = 1 mA OUTPUT PULSE (IF = IR = 10 mA; measured at iR(REC) = 1 mA) IF INPUT SIGNAL Figure 1. Recovery Time Equivalent Test Circuit ... Mounting Techniques Reference Manual, SOLDERRM/D. SOLDERING FOOTPRINT* STYLE 1: PIN 1. CATHODE (POLARITY BAND) 2. ANODE STYLE 2: NO POLARITY STYLE 1 …
A guide to oscilloscope diagnostics
mopar.picoauto.comPico Technology is unique within the automotive industry, both in the way we specialize in the manufacture of PC-based scopes for automotive use, and how we work with an ever increasing number of the world’s leading vehicle manufacturers for dealer-level oscilloscope diagnostics. This experience ensures the equipment you buy from us stays
Chapter 17: Fundamentals of Time and Frequency
tf.nist.govThe oscilloscope will display two sine waves (Fig. 17.5). The top sine wave represents a signal from the DUT, and the bottom sine wave represents a signal from the reference. If the two frequencies were exactly the same, their phase relationship would not change and both would appear to be stationary on the oscilloscope display.
Similar queries
A621 A622 Current Probes Datasheet, Digital, Oscilloscopes, TPS2000, Series oscilloscopes, Texas Instruments, Infiniium V-Series Oscilloscopes, Differential, Probes, Electrician CV, Oscilloscope, Basic electronics circuits, Fundamentals, Experiment, The oscilloscope, Use an oscilloscope, RC Circuits, Software, Software oscilloscope, Introduction to comparators, their parameters and basic, Introduction to comparators, their parameters and basic applications, Clemson, SPECTRUM ANALYZER, Basic, PC Oscilloscope software, CONSIDER WHEN CHOOSING AN, Probe, CONSIDER WHEN CHOOSING AN OSCILLOSCOPE, ELECTRICAL AND ELECTRONICS ENGINEERING, Chapter 1.1 A Brief History of Video Games, OSCILLOSCOPE INSTRUCTION, Table Of Contents, Sequence, Series, Introduction to Oscilloscope Probes: Lab Experiment, 2 UTILISATION DE L’OSCILLOSCOPE, Mesures, De l, B1500A Semiconductor Device Analyzer, Microsquirt Hardware Manual, DSO138 Oscilloscope Kit & Manual, Ethernet Compliance Testing, Dual Channel Series Handheld Oscilloscope User, PID controller, Guide, Sampling Oscilloscope, Techniques, Frequency