Example: quiz answers

5343B

2-wire level transmitter5343 BPotentiometer or Ohmic input Programmable sensor error value High measurement accuracy Unique process calibration function Programmable via standard PC ApplicationsApplicationConversion of resistance variation to standard analog currentsignals, from Ohmic level sensors or valve positions. User-defined linearization function can be activated. Technical characteristicsWithin a few seconds the user can program PR5343B tomeasure within the defined Ohmic values. Continuous check of vital stored data for safety reasons.

5343B-092718 Environmental Conditions Operating temperature.....-40°C to +85°C Calibration temperature..... 20...28°C

Tags:

  Temperatures, 3534b

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 5343B

1 2-wire level transmitter5343 BPotentiometer or Ohmic input Programmable sensor error value High measurement accuracy Unique process calibration function Programmable via standard PC ApplicationsApplicationConversion of resistance variation to standard analog currentsignals, from Ohmic level sensors or valve positions. User-defined linearization function can be activated. Technical characteristicsWithin a few seconds the user can program PR5343B tomeasure within the defined Ohmic values. Continuous check of vital stored data for safety reasons.

2 The transmitter is protected against polarity reversal. PR5343B is configured to the current task by way of a PC, thePReset software and the communications interface Loop Link. The PRelevel configuration tool included in the PResetsoftware has been developed specifically for the configurationof level applications. Among other things, it contains afunction for on line measurement of input span as well as alinearization function for volume linear output from horizontalcylindrical tanks. Mounting / installationFor DIN form B sensor head or DIN rail mounting with aspecial fitting.

3 NB: As / Ex barrier for 5343B we recommend 5104B,5114B or 5116B. This page is automatically generated on the basis of information provided on and affiliated websites. It is provided to you as a service and for informationpurpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability5343B-010919 Environmental ConditionsOperating C to +85 CCalibration CRelative < 95% RH (non-cond.)Protection degree ( ).

4 IP68 / IP00 Mechanical 44 x mmWeight gWire x mm2 stranded wireScrew terminal 4 gCommon specificationsSupplySupply VDCI nternal power WResponse timeResponse time (programmable).. sVoltage VDCWarm-up LinkSignal / noise 60 than of sel. rangeSignal dynamics, bitSignal dynamics, bitEffect of supply voltage < of span / VDCEMC immunity < of spanInput specificationsCommon input specificationsMax. of selected max. valueLinear resistance inputMeasurement range / min. range(span).

5 K / 1 k Cable resistance per wire(max.)..100 Sensor > 25 A, < 120 AEffect of sensor cable resistance(3-wire)..< / Sensor error measurement k Output specificationsCurrent outputSignal mAMin. signal mALoad (@ current output).. (Vsupply - 8) / [ ]Load of span / 100 Sensor error mANAMUR NE43 mA / mACommon output specificationsUpdating msof of the presently selectedrangeObserved authority 020/2011 ApprovalsATEX 2014/34 XEAC Ex TR-CU 012 f. Certific. No.