Example: dental hygienist

E R U Series MS2 Magnesense II Differential Pressure ...

Differential Pressure TransmittersPRESSUREDWYER INSTRUMENTS, INC.| II Differential Pressure TransmitterMonitors Pressure , Air Velocity & Air Flow, BACnet/Modbus CommunicationsSPECIFICATIONSS upported Baud Rates: 9600, 19200, 38400, 57600, 76800, Size: : Bits: : Air and non-combustible, compatible Materials: Consult Accuracy: 1% FS for (40 Pa), (50 Pa), (100 Pa), 2 (500Pa), 3 (750 Pa), 5 (1250 Pa), 10 (2 kPa), 15 (3 kPa), 25 (5 kPa), 28 ( ); 2% FS for (25 Pa), 1 (250 Pa), and all bi-directional : 1% / year Limits: 0 to 150 F (-18 to 66 C).

D i f f e r e n t i a l P r e s s u r e T r a n s m i t t e r s P R E S S U R E 54 DWYER INSTRUMENTS, INC. | www.dwyer-inst.com Magnesense® II Differential Pressure Transmitter M onitr sP e u,AV l cy& FwB C/ db® m a SPECIFICATIONS Supported Baud Rates: 9600, 19200, 38400, 57600, 76800, 115200. Data Size:f 8. Parity: None. Stop Bits: 1. Service: Air and non-combustible, compatible gases ...

Tags:

  Inst, Dwyer inst, Dwyer, E t t, S e s

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of E R U Series MS2 Magnesense II Differential Pressure ...

1 Differential Pressure TransmittersPRESSUREDWYER INSTRUMENTS, INC.| II Differential Pressure TransmitterMonitors Pressure , Air Velocity & Air Flow, BACnet/Modbus CommunicationsSPECIFICATIONSS upported Baud Rates: 9600, 19200, 38400, 57600, 76800, Size: : Bits: : Air and non-combustible, compatible Materials: Consult Accuracy: 1% FS for (40 Pa), (50 Pa), (100 Pa), 2 (500Pa), 3 (750 Pa), 5 (1250 Pa), 10 (2 kPa), 15 (3 kPa), 25 (5 kPa), 28 ( ); 2% FS for (25 Pa), 1 (250 Pa), and all bi-directional : 1% / year Limits: 0 to 150 F (-18 to 66 C).

2 Pressure Limits: 1 psi max., operation; 10 psi Requirements: 10 to 35 VDC (2-wire), 17 to 36 VDC or isolated to 33 VAC (3-wire).Output Signals:4 to 20 mA (2-wire), 0 to 5 VDC, 0 to 10 VDC (3-wire).Response Time: Adjustable: to 15 sec. time constant. Provides a 95%response time of to 45 & Span Adjustments: Digital push Resistance: Current Output: 0 to 1250 max; Voltage Output: Min. loadresistance 1 k .Current Consumption: 40 mA (Optional): 5 digit Connections: 3-wire removable European style terminal block for 16 to22 Entry: 1/2 NPS Connection: 3/16 ID tubing (5 mm ID); Max.

3 OD 9 Rating: Orientation: Diaphragm in vertical : oz (230 g).Agency Approvals: BTL, Series MS2 Magnesense II Differential Pressure Transmittercombines theproven stable Hall Effect sensing technology of our original Series MS with additionalfeatures to reduce installation time and simplify ordering. In this second generationtransmitter, we have added additional field selectable Pressure ranges so that each modelcan have four selectable ranges along with four additional bidirectional ranges. When usingthe pluggable integral display or the portable remote display tool, both Metric and Englishengineering units can be selected via on board dip switches.

4 Dual current and voltageoutputs allow users to simultaneously take either a current or voltage output to theirbuilding controller and have a local test circuit for verification of the output reading. Thevoltage output can be selected to be either 0 to 5 VDC or 0 to 10 VDC, while the current isalways 4 to 20 mA. Both the current and voltage output can also be inverted. The MS2can also be ordered with either a BACnet or MODBUS Communications protocol outputthat will allow the transmitters to be daisy-chained the original Series MS, the second generation transmitter can be used as a linearpressure output or a linear velocity output with the square root extraction done in thetransmitter.

5 Additional parameters have been included to expand the square root capabilityto include flow and Modbus Communications protocol recommend limiting the number of nodesin any segment to 32. Therefore, the transceiver may be rated at one unit load. Fractionalloads are also acceptable. The MS2 accounts as an eighth of a load on the MSTP , , , , , , , 2, 3, 5 1, 2, 3, 510, 15, 25,28 ModelMS2-W101MS2-W111MS2-W102MS2-W112MS2 -W103Pa25, 40 50, 125 25, 40, 50, 125250, 500, 750,1250 250, 500, 750, 12502500, 3500,5000, 6975mm , 4, 6,10 , 4, 6, 1025, 50, 75,125 25, 50, 75, 125250, 350,500, MS2 3-7/16[ ]2-41/64[ ]1/2 NPT21/32[ ]21/32[ ]29/32[ ]1/2[ ]57/64[ ](3)

6 3/16 [ ] HOLESEQUALLY SPACED ON [ ] BC2-11/64[ ]2-9/16[ ] 3-7/16[ ]1/2 NPT25/64[ ]1-41/64[ ]2-41/64[ ]21/32[ ]57/64[ ]21/32[ ]29/32[ ]1/2[ ]2-11/64[ ]3-11/32[ ]3-1/2[ ]7-3/4[ ]3/8[ ]Wall Mount BracketDuct Mount BracketDIN Mount BracketModbus is a registered trademark of Schneider Automation, here to watch product videoProcess Tubing Options: See page 547 (Gage Tubing Accessories)OPTIONSAdd -LCD to end of model numbers for units with display Example: MS2-W101-LCDAdd -BC to end of model numbers for BACnet CommunicationsExample: MS2-W101-BCAdd -MC to end of model numbers for Modbus CommunicationsExample: MS2-W101-MCAdd -NIST to end of model numbers for NIST Traceable CertificateExample: MS2-W101-NISTAdd -FC to end of model numbers for Factory Calibration CertificateExample: MS2-W101-FCChange W to D for Duct Mount Static ProbeExample: MS2-D101 Change W to N for DIN Rail MountingExample.

7 MS2-N101 ACCESSORIESA-151,Cable gland for 5 to 10 mm diameter cableA-MS2-LCD,Field Upgradeable DisplayA-435-A,Remote Display ToolA-480, Plastic Static Pressure TipA-481,Installer kit. Includes 2 plastic static Pressure tips and 7 ft ( m) of PVCtubingA-489,4 303 SS Straight Static Pressure Tip with FlangeA-302F-A,4 303 SS Static Pressure Tip with mounting flange. For 3/16 ID rubberor plastic tubingSCD-PS,100 to 240 VAC/VDC to 24 VDC Power.


Related search queries