Example: bankruptcy

FUJITSU Server PRIMERGY RX2530 M1

upgrade and Maintenance Manual - EnglishFUJITSU Server PRIMERGY RX2530 M1 upgrade and Maintenance ManualAugust User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual free to send us your comments by e-mail to documentation according to DIN EN ISO 9001:2008To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2008. cognitas. Gesellschaft f r Technik-Dokumentation and TrademarksCopyright 2015 FUJITSU Technology Solutions rights subject to availability; right of technical modifications hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. FUJITSU assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX2530 M1 Upgrade and Maintenance Manual August 2015

Tags:

  Fujitsu, Server, Primergy, Upgrade, Fujitsu server primergy rx2530 m1, Rx2530, Fujitsu server primergy rx2530 m1 upgrade

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of FUJITSU Server PRIMERGY RX2530 M1

1 upgrade and Maintenance Manual - EnglishFUJITSU Server PRIMERGY RX2530 M1 upgrade and Maintenance ManualAugust User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual free to send us your comments by e-mail to documentation according to DIN EN ISO 9001:2008To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2008. cognitas. Gesellschaft f r Technik-Dokumentation and TrademarksCopyright 2015 FUJITSU Technology Solutions rights subject to availability; right of technical modifications hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. FUJITSU assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

2 No part of this manual may be reproduced in any form without the prior written permission of , Windows, Windows Server , and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other M1 upgrade and Maintenance ManualBefore reading this manualFor your safetyThis manual contains important information for safely and correctly using this read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interferenceThis product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components.

3 Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety useThis product has been designed and manufactured to be used in commercial and/or industrial areas as a used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX Server systems).The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be and Maintenance Manual RX2530 M1 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use").

4 Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of FUJITSU if intending to use this product for high safety against momentary voltage dropThis product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.(This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of JapanDocuments produced by FUJITSU may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above Current Standards This product conforms to harmonic current standard JIS C for the Japanese market: About SATA hard disk drivesThe SATA version of this Server supports hard disk drives with SATA / BC-SATA storage interfaces.

5 Please note that the usage and operation conditions differ depending on the type of hard disk drive refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: M1 upgrade and Maintenance ManualOnly for the Japanese market:Shielded LAN cables should be used in this for the Japanese market:IAlthough described in this manual, some sections do not apply to the Japanese market. These options and routines include: CSS (Customer Self Service) USB Flash Module (UFM) upgrade and Maintenance Manual RX2530 M1 Version historyIssue numberReason for / January 2015 Initial / April 2015 Fan sponges added, SATA onboard mounting order added, new heat sink type added, cable tie for front VGA cable added, iRMC microSD card / August 2015 Screws list updated; mounting order with up to eight HDD/SSD bays updated; notes for BC-SAS / BC-SATA drives added; ServerView RAID Manager naming scheme for PCIe-SSDs added; cable tie for front panel cable addedRX2530 M1 upgrade and Maintenance ManualContents1 Introduction.

6 Conventions .. 222 Before you start .. of procedures .. Replaceable Units (CRU) .. and Repair Units (URU) .. Replaceable Units (FRU) .. task duration .. you need at hand .. you need at hand .. 313 Important information .. instructions .. STAR .. conformity .. Class A Compliance Statement .. protection .. 434 Basic hardware procedures .. diagnostics information .. the defective Server .. the error class .. Error indicator .. Self Service (CSS) indicator .. the defective component .. diagnostic indicators on the system board .. down the Server .. 48 upgrade and Maintenance Manual RX2530 the Server from the mains .. access to the component .. the Server out of the rack .. the Server from the rack .. the top covers .. the top covers .. the Server in the rack .. the Server into the rack.

7 The Server to the mains .. on the Server .. riser modules .. a riser module .. a riser module .. fan sponges .. the fan sponges .. the fan sponges .. CPU air guides .. the CPU air guides .. the CPU air guides .. 695 Basic software procedures .. the maintenance task .. BitLocker functionality .. SVOM boot watchdog functionality .. boot watchdog settings .. boot watchdog settings .. backup and optical disk media .. and configuring the backup software solution .. on Server maintenance in a Multipath I/O environment .. on the ID indicator .. the maintenance task .. or recovering the system board BIOS and iRMC .. or recovering the system board BIOS .. or recovering the iRMC .. system information backup / restore .. RAID controller firmware .. 82RX2530 M1 upgrade and Maintenance Option ROM scan .. and configuring the backup software solution .. the boot retry counter .. the boot retry counter.

8 The boot retry counter .. the error status after replacing memory modules or processors .. modules .. SVOM boot watchdog functionality .. replaced components in the system BIOS .. the memory mode .. the system time settings .. and clearing the System Event Log (SEL) .. the SEL .. the SEL .. the NIC configuration file in a Linux environment .. BitLocker functionality .. a RAID array rebuild .. up changed MAC / WWN addresses .. up MAC addresses .. up WWN addresses .. the Chassis ID Prom Tool .. LAN teaming .. replacing / upgrading LAN controllers .. replacing the system board .. off the ID indicator .. a fan test after replacing a defective fan .. 1006 Power supply .. information .. supply unit configurations .. rules .. a power supply unit .. steps .. the dummy cover .. a power supply unit .. steps .. 108 upgrade and Maintenance Manual RX2530 a power supply unit.

9 Steps .. a power supply unit .. the dummy cover .. a power supply unit .. steps .. the defective power supply unit .. the new power supply unit .. steps .. 1147 Hard disk drives / solid state drives .. information .. HDD/SSD configurations .. the HDD/SSD bays .. with up to four HDD/SSD modules .. with up to eight HDD/SSD modules .. with up to 10 HDD/SSD modules .. HDD/SSD modules .. steps .. a HDD/SSD dummy module .. a HDD/SSD module .. steps .. HDD/SSD modules .. steps .. a HDD/SSD module .. a HDD/SSD dummy module .. steps .. a HDD/SSD module .. steps .. the defective HDD/SSD module .. the new HDD/SSD module .. steps .. the 4 x HDD backplane .. steps .. the defective 4 x HDD backplane .. the new 4 x HDD backplane .. steps .. 135RX2530 M1 upgrade and Maintenance the 10 x HDD backplane.

10 Steps .. the SAS expander board .. the defective 10 x HDD backplane .. the new 10 x HDD backplane .. the SAS expander board .. steps .. the SAS expander board .. steps .. the defective SAS expander board .. the new SAS expander board .. steps .. configuration from up to four to up to eight HDDs/SSDs .. steps .. the second HDD backplane .. additional HDD/SSD modules .. steps .. HDD configurations .. the HDD bays .. HDD modules .. steps .. a HDD dummy module .. a HDD module .. steps .. HDD modules .. steps .. a HDD module .. a dummy module .. steps .. a HDD module .. steps .. the defective HDD module .. the new HDD module .. steps .. the HDD backplane .. steps .. the defective HDD backplane .. the new HDD backplane .. steps .. 154 upgrade and Maintenance Manual RX2530 M1 Contents8 Fans.


Related search queries