Example: tourism industry

Programmable DC Electronic Loads

Programmable DC Electronic Loads8600 SeriesData data subject to change B&K Precision Corp. 2015 The 8600 Series Programmable DC electronicloads provide the performance of modular systemDC Electronic Loads in a compact benchtop formfactor. With fast transient operation speeds andhigh 16-bit measurement resolution, these standalone DC Loads can be used for testing andevaluating a variety of DC sources such as DCpower supplies, DC-DC converters, batteries,battery chargers, and photovoltaic DC Loads can operate in constant current(CC), constant voltage (CV), constant resistance(CR), or constant power (CW)

your electronic load from a PC. PC software is providedT for front panel emulation, generating and executing test sequences, or logging measurement data without the need to write source code. Additionally, this application ... Programmable DC Electronic Loads

Tags:

  Electronic, Load, Programmable, Electronic load, Programmable dc electronic

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Programmable DC Electronic Loads

1 Programmable DC Electronic Loads8600 SeriesData data subject to change B&K Precision Corp. 2015 The 8600 Series Programmable DC electronicloads provide the performance of modular systemDC Electronic Loads in a compact benchtop formfactor. With fast transient operation speeds andhigh 16-bit measurement resolution, these standalone DC Loads can be used for testing andevaluating a variety of DC sources such as DCpower supplies, DC-DC converters, batteries,battery chargers, and photovoltaic DC Loads can operate in constant current(CC), constant voltage (CV), constant resistance(CR), or constant power (CW)

2 Mode and be configured to provide a dynamically changing loadto the DC source with fast load switching internal, external, and remote triggeringoptions allow the dynamic load behavior to besynchronized with other productivity by saving your test parameters into any one of the 100 memoryFeatures Voltage range up to 500 V Current range up to 240 A CC/CV/CR/CW operating modes 16-bit voltage and current measurement system providing 1 mV / mA resolution Transient mode up to 25 kHz in CC mode List mode function Store and recall up to 100 setups Adjustable slew rate in CC mode Flexible triggering options via front panel, external input, timer.

3 Or bus Built-in battery test function with voltage level, capacity level, and timer stop conditions Test modes to validate the OCP/OPP protection functions of a power supply CR-LED mode to simulate the loading behavior of typical LEDs Remote sense Analog current control and monitoring Thermostatically controlled fan Standard USB (USBTMC-compliant), RS232, and GPIB interfaces supporting SCPI commands for remote control OVP/OCP/OPP/OTP including local and remote reverse voltage (LRV/RRV) protection Compact 19 half-rack form factor allows forside-by-side rack mounting of two units (models 8600, 8601 and 8602)Model8600860186028610861286148616 Power150 W250 W200 W750 W750 W1500 W1200 WOperatingVoltage0 120 V0 120 V0 500 V0 120 V0 500 V0 120 V0 500 VRated Current0 30 A0 60 A0 15 A0 120 A0 30 A0 240 A0 60 Aareas for quick system recall.

4 All load parameterssuch as voltage, current, slew rate, and widthcan be set via the front panel or programmedremotely. The 8600 Series provides standardUSB (USBTMC-compliant), GPIB, or RS-232serial interfaces for remote communication. To ensure the reliability of your testing, the 8600 Series provides a power-on system self-test andnumerous protection features: overtemperature(OTP), overvoltage (OVP), overcurrent (OCP),overpower (OPP), and local/remote reverse voltage (LRV/RRV) ApplicationsThe 8600 Series provides a built-in battery testmode to measure the ampere-hour (Ah)

5 Characteristic of a battery and a unique CR-LEDmode to simulate the loading behavior of a typical DC Electronic Loads8600 Series2 Models 8600, 8601 & 8602 Bright dual-line displayThe 8600 Series display shows both measured inputvalues and set parameters panelRear panelRotary controlknobCooling fanRS-232interfaceUSBinterfaceGPIB interfaceCurrent monitor BNC outputOutputs a 0-10 V signal that follows0-full range of the input terminal blockExternal trigger, external analog programming,external input On/Off control, voltage fault pin,and remote sense terminalsLine voltage selectorNumeric keypad Function keys Cursor keysLoad input terminalIntuitive user interfaceThe numeric keys and rotary knob provide a convenient interface for setting the operating mode and desired current, voltage, and resistance levels quicklyand precisely.

6 High current test lead accessory model DC Electronic Loads8600 Series3RS-232interfaceUSBinterfaceGPIB interfaceLine voltageselector Models 8610, 8612, 8614 & 8616 NumerickeypadFunctionkeysCursorkeysBrigh t dual-line displayThe 8600 Series display shows both measuredinput values and set parameters keysCooling fanI/O terminal blockExternal trigger, external analog programming, external inputOn/Off control, voltage fault pin, and remote sense terminalsInput fuse holderAC lineinputCurrent monitor BNC outputOutputs a 0-10 V signal that follows0-full range of the input terminalsFront panelRear DC Electronic Loads8600 Series4 Flexible operation Automatic test modeThe 8600 Series can execute multiple testsequences in automatic test mode.

7 Up to 100different sequences can be linked to run steps ofvarious operating modes and loading sequence can also be programmed withupper and lower limit Pass/Fail criteria. Whenapplied in production testing, you can easilyjudge whether the test parameters of yourdevices are within the specification limits andadjust your process according to the modeNot limited to just switching between two levels,list mode lets you generate more complexsequences of input changes with several differentlevels. Up to 7 groups of list files can be savedand executed in CC mode via internal or externaltrigger.

8 Each list can contain up to 84 steps withvarying slew rates and a minimum width time of20 s per modeUse the load s unique CR-LED operating modeto test LED drivers. This function allows users toconfigure the LED s operating resistance and forward voltage to simulate the loading behaviorof typical voltage operationThe 8600 Series can operate at low voltages for applications such as fuel cell and solar cell = Forward voltage of the LEDRd = LED operating resistanceVo = LED operating voltageIo = LED operating currentVoltage (V)Current (A)123450 Typical minimum operating voltage at full scale V8614861086028601861686008612 IVLED I-V CurveTransient operation enables the load to periodicallyswitch between two load levels (A/B).

9 A powersupply s regulation and transient characteristic canbe evaluated by monitoring the supply s output voltage under varying combinations of load levels,duty cycle, and slew rate. The 8600 Series cansimulate these conditions in CC, CV, CW, and operationA levelTrigger012345678 StepstASlew RateB levelAtIVCC 1 A1 s s sCV 3 VIoVdVoRdCW WCR 2 passpasspassfail DC Electronic Loads8600 Series5 Powerful communication interfacesThe 8600 Series provides standard GPIB, USB,and RS232 interfaces for remote interfaces offer SCPI and USBTMC standard communication protocols to controlyour Electronic load from a software is provided for front panel emulation,generating and executing test sequences.

10 Or logging measurement data without the need towrite source code. Additionally, this applicationsoftware integrates with NI Data Dashboard forLabVIEW apps, which allows users to create acustom dashboard on a tablet computer or smartphone to remotely monitor 8600 Series DC Loads via this PC software. Remote monitoring on iOS, Android or Windows 8 compatible tablets or smartphones via NI Data Dashboard for LabVIEW apps Log voltage, current, and power values with timestamp Run transient operation and list mode programs remotely Create an unlimited number of external list files to be executed from PC memoryApplication softwareIn addition to front panel and remote interfacecontrol, current values can also be programmedwith an analog control signal.