RV2012 . 2512. 3012. Owner's Manual Xantrex RV Series inverter / charger Xantrex RV Series inverter / charger Owner's Manual TABLE OF CONTENTS. IMPORTANT SAFETY INSTRUCTIONS .. 1. THEORY OF inverter 4. Regulation ..4. Search Sense Mode Using Optional RC7 BATTERY charger .. 6. Theory of Transfer Switching Speed ..6. Battery Terminology ..6. charger Three Stage Battery BATTERY charger CONTROLS AND LED 8. charger LED ..8. Generator Selection of Battery Battery Care and Maintenance ..10. Battery Battery Battery Hookup 14. AC WIRING .. 15. i Xantrex RV Series inverter / charger Owner's Manual Overview.

Xantrex RV Series Inverter/Charger Owner™s Manual 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS! This manual contains important safety and …

Tags:

  Manual, Series, Charger, Inverter, Xantrex, Manual xantrex rv series, Xantrex rv series inverter charger

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RV2012 2512 3012 Owner’s Manual Xantrex RV Series …

1 RV2012 . 2512. 3012. Owner's Manual Xantrex RV Series inverter / charger Xantrex RV Series inverter / charger Owner's Manual TABLE OF CONTENTS. IMPORTANT SAFETY INSTRUCTIONS .. 1. THEORY OF inverter 4. Regulation ..4. Search Sense Mode Using Optional RC7 BATTERY charger .. 6. Theory of Transfer Switching Speed ..6. Battery Terminology ..6. charger Three Stage Battery BATTERY charger CONTROLS AND LED 8. charger LED ..8. Generator Selection of Battery Battery Care and Maintenance ..10. Battery Battery Battery Hookup 14. AC WIRING .. 15. i Xantrex RV Series inverter / charger Owner's Manual Overview.

2 15. AC Connections ..15. Important Precautions ..15. Ground Fault Interrupting Outlets (GFIs)..16. DC WIRING .. 16. Safety DC Over-Current Connection of Grounding and Battery STACKING 18. DC Connections for Stacked Inverters ..18. AC Wiring for Stacked Inverters ..19. Operation ..19. Theory of Search Sense Mode Operation with Stacked RC6 REMOTE 21. Installation ..21. RC7 REMOTE 22. Installation ..22. Programming the RC7 ..22. User Menu ..23. Meters Menu ..24. Setup Menu ..24. BATTERY CABLE 26. Battery Cable Installation with External Transfer Relay (120/240 System).

3 27. ii Xantrex RV Series inverter / charger Owner's Manual Mobile TROUBLESHOOTING GUIDE .. 29. APPLICATIONS .. 30. Resistive Inductive Loads ..30. Problem Loads ..30. Typical Battery Draw of Common Appliances ..32. English to Metric Wire Conversion ..33. RC7 Menu Map ..34. TECHNICAL INFORMATION .. 36. RV Series LIMITED 37. Notice of Copyright Xantrex RV Series inverter / charger December 2002 Xantrex International. All rights reserved. Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING, Xantrex TECHNOLOGY INC. ( Xantrex ). (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR.

4 OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE. OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER'S RISK. Date and Revision December 2002, Revision 2 Part Number 445-0202-01-01. Contact Information Web: Email: Phone: 1-800-670-0707 (toll free) 1-604-422-2777 (direct). Fax: 1-604-420-2145. iii Xantrex RV Series inverter / charger Owner's Manual IMPORTANT SAFETY INSTRUCTIONS.

5 SAVE THESE INSTRUCTIONS! This Manual contains important safety and operating instructions as prescribed by UL. specifications for inverters used in land vehicle applications. This Manual covers Xantrex RV. Series inverter /Chargers models RV2012 , RV2512, and RV3012. General Precautions 1. Before using the inverter / charger , read all instructions and cautionary markings on (1) the inverter / charger , (2) the batteries and (3) all appropriate sections of this instruction Manual . 2. CAUTION: To reduce risk of injury, charge only deep-cycle lead acid, lead antimony, lead calcium, gel cell, absorbed mat, or NiCad/NiFe type rechargeable batteries.

6 Other types of batteries may burst, causing personal injury and damage. 3. Do not expose inverter / charger to rain, snow or liquids of any type. The inverter is designed for indoor mounting only. Protect the inverter from splashing when used in vehicle applications. Do not mount the inverter in unventilated enclosures or in the engine compartment. 4. Do not disassemble the inverter / charger ; take it to a qualified Xantrex service center when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire. 5. To reduce risk of electric shock, disconnect all wiring before attempting any maintenance or cleaning.

7 Turning off the inverter will not reduce this risk. Solar modules produce power when exposed to light cover them with opaque material before servicing any connected equipment. 6. WARNING: WORKING IN THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION. Provide ventilation to outdoors from the battery compartment. The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas in pockets at the top of the compartment. Vent the battery compartment from the highest point. 7. NEVER charge a frozen battery.

8 8. No terminals or lugs are required for hook-up of the AC wiring. AC wiring must be no less than 10 AWG ( mm2) gauge copper wire and rated for 75 C or higher. Battery cables must be rated for 75 C or higher and should be no less than #2 AWG ( mm2) gauge. Crimped and sealed copper ring terminal lugs with a 5/16 hole should be used to connect the battery cables to the DC terminals of the inverter / charger . Soldered cable lugs are also acceptable. 9. Torque all AC wiring connections to 20 inch-pounds. Torque all DC cable connections to 12. foot-pounds. Be extra cautious to reduce the risk of dropping a metal tool onto batteries.

9 It could short-circuit the batteries or other electrical parts, resulting in sparks that could cause an explosion. 1. Xantrex RV Series inverter / charger Owner's Manual 10. Symbols used in this Manual and on the inverter / charger are: Chassis Phase AC Output AC Input 1. Tools required to make AC wiring connections: Wire strippers, 1/2" (13 mm) open-end wrench or socket, Phillips screwdriver #2, Slotted screwdriver 1/4" (6 mm) blade. 2. This inverter / charger is intended to be used with a battery supply with a nominal voltage of 12. volts DC. 3. For instructions on shelf mounting, see Installation on page 14.

10 For battery installation and maintenance: read the battery manufacturer's installation and maintenance instructions prior to operating. 4. No AC or DC disconnects are provided as an integral part of this inverter . Both AC and DC. disconnects must be provided as part of the system installation. See SYSTEM SAFETY. WIRING REQUIREMENTS section of this Manual . 5. No over-current protection for the battery supply is provided as an integral part of this inverter . Over-current protection of the battery cables must be provided as part of the system installation. See DC Over-Current Protection on page 16.