Compact Operating Instructions SIPART PS2 ( ). Electropneumatic positioners EDITION 05/2018 Introduction 1. Safety instructions 2. Installing/mounting 3. SIPART . Connecting 4. Electropneumatic positioners SIPART PS2 ( ) 5. Commissioning Service and maintenance 6. Compact Operating Instructions Technical data 7. Appendix A. Accessory part sealing plug /. thread adapter B. with and without HART with PROFIBUS PA. with FOUNDATION Fieldbus 05/2018. A5E03436620-AD. Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER. indicates that death or severe personal injury will result if proper precautions are not taken.

4.2.6.5 M12 connector for connecting the external position detection system (-Z D54).....39 4.2.6.6 M12 connector for connecting the alarm module 6DR4004-6A / -8A (-Z D55).....40 4.2.6.7 M12 connector for connecting the SIA module 6DR4004-6G /-8G (-Z D56).....40 4.2.6.8 M12 connector for connecting the mechanical limit switch module 6DR4004-6K ...

Tags:

  Connectors, Tripass, M12 connector, Sipart ps2, 6dr5

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SIPART PS2 (6DR5) - Siemens

1 Compact Operating Instructions SIPART PS2 ( ). Electropneumatic positioners EDITION 05/2018 Introduction 1. Safety instructions 2. Installing/mounting 3. SIPART . Connecting 4. Electropneumatic positioners SIPART PS2 ( ) 5. Commissioning Service and maintenance 6. Compact Operating Instructions Technical data 7. Appendix A. Accessory part sealing plug /. thread adapter B. with and without HART with PROFIBUS PA. with FOUNDATION Fieldbus 05/2018. A5E03436620-AD. Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER. indicates that death or severe personal injury will result if proper precautions are not taken.

2 WARNING. indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION. indicates that minor personal injury can result if proper precautions are not taken. NOTICE. indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.

3 Proper use of Siemens products Note the following: WARNING. Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens . Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described.

4 Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Document order number: A5E03436620 Copyright Siemens AG 2018. Division Process Industries and Drives 03/2018 Subject to change All rights reserved Postfach 48 48. 90026 N RNBERG. GERMANY. Table of contents 1 Purpose of this Product Checking the Security Transportation and Notes on 2 Safety Precondition for Warning symbols on the Laws and Conformity with European Improper device Use in areas subject to explosion 3 Basic safety Proper Mounting to linear Mounting to part-turn Positioners subjected to fast acceleration or strong Procedure locking the Installing option Internal NCS 4 Basic safety Additional safety notes for PA and Electrical SIPART PS2 with and without Basic electronics, 2/3/4-wire, with connection type 4-wire, connection diagram (with and without HART).

5 31. SIPART PS2 with PROFIBUS SIPART PS2 with FOUNDATION SIPART PS2 ( ). Compact Operating Instructions, 05/2018, A5E03436620-AD 3. Table of contents Split Option Alarm modules 6DR4004-6A and Position feedback modules 6DR4004-6J and SIA modules 6DR4004-6G and Mechanical limit switch modules 6DR4004-6K and Option device version M12 m12 connector in basic device SIPART PS2 with and without m12 connector in basic device SIPART PS2 with PROFIBUS m12 connector in basic device SIPART PS2 with FOUNDATION m12 connector for connecting the position feedback module 6DR4004-6J / 8J (-Z D53)..39. m12 connector for connecting the external position detection system (-Z D54)..39. m12 connector for connecting the alarm module 6DR4004-6A / -8A (-Z D55)..40. m12 connector for connecting the SIA module 6DR4004-6G /-8G (-Z D56)..40. m12 connector for connecting the mechanical limit switch module 6DR4004-6K (-Z D57)..40. Pneumatic Pneumatic connection for Pneumatic connection for and 5 Basic safety Safety notes for operation with natural Increased sound pressure Sequence of automatic Overview of initialization parameters 1 to Purge air Commissioning linear Preparing linear actuators for Automatic initialization of linear Manual initialization of linear Commissioning part-turn Preparing part-turn actuators for Automatic initialization of part-turn Manual initialization of part-turn 6 Service and Basic safety Cleaning of the Positioners with polycarbonate enclosure , aluminum enclosure , and flameproof aluminum enclosure Positioners with stainless steel enclosure , flameproof stainless steel enclosure , and aluminum enclosure single-acting Maintenance and repair SIPART PS2 ( ).

6 4 Compact Operating Instructions, 05/2018, A5E03436620-AD. Table of contents Return 7 Technical All device Operating Pneumatic Certificates and Explosion Breakdown of the article Protection against explosion device and option Maximal permissible ambient temperature Natural gas as actuator SIPART PS2 with and without Electrical Communication (HART)..76. SIPART PS2 with PROFIBUS PA/with FOUNDATION Electrical PROFIBUS PA FOUNDATION Fieldbus Option Alarm Position feedback SIA Mechanical limit switch EMC filter Internal NCS modules 6DR4004-5L and External position External NCS sensors 6DR4004-6N/8N and A Technical B Accessory part sealing plug / thread Intended use of accessory Safety instructions for accessory Technical specifications of accessory Dimensional drawings of accessory SIPART PS2 ( ). Compact Operating Instructions, 05/2018, A5E03436620-AD 5. Table of contents SIPART PS2 ( ). 6 Compact Operating Instructions, 05/2018, A5E03436620-AD.

7 Introduction 1. Purpose of this documentation These instructions are a brief summary of important features, functions and safety information, and contain all information required for safe use of the device. Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of operation. The instructions are aimed at persons who install and commission the device. To realize optimum performance from the device, read the complete operating instructions. See also SIPART PS2 product information ( ). Product compatibility The following tables describe compatibility between manual edition, device revision, engineering system and associated EDD. HART. Manual Comments Device revision Compatible version of device integration package edition 05/2018 New manual FW: or higher SIMATIC PDM EDD: or higher edition Device revision 6 or higher SIMATIC PDM SP1 EDD: or higher AMS Device Manager EDD: or higher SITRANS DTM EDD: or higher Field communicator EDD: or higher 05/2017 New device HART SIMATIC PDM EDD: or higher features FW: or higher SIMATIC PDM SP1 EDD: or higher Device revision 6 or higher AMS Device Manager EDD: or higher SITRANS DTM EDD: or higher Field communicator EDD: or higher SIPART PS2 ( ).

8 Compact Operating Instructions, 05/2018, A5E03436620-AD 7. Introduction Purpose PROFIBUS PA. Manual Comments Device revision Compatible version of device integration package edition 05/2018 New manual FW: or higher SIMATIC PDM EDD: or higher edition SIMATIC PDM SP1 EDD: or higher SITRANS DTM EDD: or higher 05/2017 New device PROFIBUS PA SIMATIC PDM EDD: or higher features FW: or higher SIMATIC PDM SP1 EDD: or higher SITRANS DTM EDD: or higher FOUNDATION Fieldbus Manual Comments Device revision Compatible version of device integration package edition 05/2018 New manual FW: or higher SITRANS DTM EDD: or higher edition Device revision 3 AMS Device Manager EDD: or higher Field communicator EDD: or higher 05/2017 New device FOUNDATION Fieldbus SIMATIC PDM EDD: or higher features FW: or higher SIMATIC PDM SP1 EDD: or higher Device revision 3 SITRANS DTM EDD: or higher Purpose The electropneumatic positioner is used for the continuous control of process valves with pneumatic drives in the following industries.

9 Chemicals Oil and gas Energy production Food and beverages Pulp and paper Water/waste water Pharmaceutical industry Offshore plants Operate the device according to the specifications in section "Technical data (Page 65)". For additional information, refer to the operating instructions for the device. SIPART PS2 ( ). 8 Compact Operating Instructions, 05/2018, A5E03436620-AD. Introduction Nameplates Checking the consignment 1. Check the packaging and the delivered items for visible damages. 2. Report any claims for damages immediately to the shipping company. 3. Retain damaged parts for clarification. 4. Check the scope of delivery by comparing your order to the shipping documents for correctness and completeness. WARNING. Using a damaged or incomplete device Risk of explosion in hazardous areas. Do not use damaged or incomplete devices. Nameplates Nameplate .. Manufacturer Auxiliary power (supply air PZ). Protection class Software/hardware version Observe the operating instructions Place of manufacture Conformity with country-specific directives Auxiliary power Built-in option module Ordering supplement (Order code).

10 QR code to the mobile website with device-spe Article number cific information on the product Serial number Product name Figure 1-1 Nameplate layout, example SIPART PS2 ( ). Compact Operating Instructions, 05/2018, A5E03436620-AD 9. Introduction Security information Ex nameplate S N : ARR P3-235866. T V 11 ATEX 093266 X / 0518. IECEx TUN X / T V X . II 2 G Ex d IIC T6/T4 Gb II 2 D Ex tb IIIC T100 C Db . Ex tD A21 IP66 T100 C. , , GP. ABCD. , , AEx d IIC. , III, , GP. EFG.. , AEx tb IIIC T100 C Ta=85 C. IP66 / Type 4X. XP, , , For technical data and temperature classes, see certificate / Operating Instructions N1A6101234567. Ex d IIC. T V 17 ATEX 205947 X / IECEx TUN 0518. DIP, , , , , II 2 G Ex ia IIC T6/T4 Gb II 3 G Ex ic IIC T6/T4 Gc II 2 D Ex ia IIIC 130 C Db II 2 D Ex tb IIIC T100 C Db S-XPL/090873. II 3 G Ex ic IIC T67T4 Gc - CI I Zn 1 AEx ib IIC IS CI I, II, III Div 1 Gp A-G. CI I Zn 2 AEx nA IIC. Zn 21 AEx ib Db IIIC T110 C. NI CI I Div 2 Gp A-D.