Example: biology

Strain Gage Instrumentation

Strain Gage Instrumentation Micro-MeasurementsStress Analysis TestingStructural TestingMaterials TestingData on the VPG logo on any datasheet to go to the contents page for that section. Click on the VPG logo on any contents page to go to the main table of contents the World Goes for Precision Measurement and Americas United States Vishay Precision Group Micro-Measurements Box 27777 Raleigh, NC 27611 Ph: +1-919-365-3800 Fax: +1-919-365-3945 E-mail: China Vishay Precision Group Micro-Measurements A8220, Shanghai Jia Hua Business Center No.

Excitation Input Power Multi-Channel Remarks P3 Digital Manual, Direct-Reading 1.5 VDC Battery, USB, or AC Adapter Selectable Portable, 4-Channel, 0.1% Accuracy D4 Host PC PC Controlled via USB 1.5 VDC USB Selectable 4-Channel, 0.1% Accuracy SIGNAL CONDITIONING AMPLIFIERS Instrument Frequency Response(1) Output (±) Amplifier Gain Bridge Excitation

Tags:

  Excitation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Strain Gage Instrumentation

1 Strain Gage Instrumentation Micro-MeasurementsStress Analysis TestingStructural TestingMaterials TestingData on the VPG logo on any datasheet to go to the contents page for that section. Click on the VPG logo on any contents page to go to the main table of contents the World Goes for Precision Measurement and Americas United States Vishay Precision Group Micro-Measurements Box 27777 Raleigh, NC 27611 Ph: +1-919-365-3800 Fax: +1-919-365-3945 E-mail: China Vishay Precision Group Micro-Measurements A8220, Shanghai Jia Hua Business Center No.

2 808 Hong Qiao Road Shanghai 200030 Ph: +86-21-6448-6090, Ext. 6098 Fax: +86-21-6448-6070 E-mail: France Vishay Precision Group Micro-Measurements 16 Rue Francis Vovelle 28000 Chartres Ph: +33-2-37-33-31-20 Fax: +33-2-37-33-31-29 E-mail: Germany Vishay Precision Group Micro-Measurements Tatschenweg 1 74078 Heilbronn Ph: +49-7131-39099-0 Fax +49-7131-39099-229 E-mail: Spain Vishay Precision Group Micro-Measurements C/Copenhague, N 4, 6 y 8 - Planta 1a - Oficina 12 Edificio Al Andalus Pol gono Eur polis 28232 Las Rozas, Madrid Ph.

3 +34-916-407-624 Fax: +34-916-375-601 E-mail: United Kingdom Vishay Precision Group Micro-Measurements Stroudley Road Basingstoke Hampshire RG24 8FW Ph: +44-(0)125-646-2131 Fax: +44-(0)125-647-1441 E-mail: Gage InstrumentationVishay Precision Box 27777 Raleigh, NC : +1-919-365-3800 Fax: + ALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, Vishay Precision Group )

4 , disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product specifications do not expand or otherwise modify Vishay Precision Group s terms and conditions of purchase, including but not limited to, the warranty expressed Precision Group makes no warranty, representation or guarantee other than as set forth in the terms and conditions of purchase. To the maximum extent permitted by applicable law, Vishay Precision Group disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii)

5 Any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and provided in datasheets and/or specifications may vary from actual results in different applications and performance may vary over time. Statements regarding the suitability of products for certain types of applications are based on Vishay Precision Group s knowledge of typical requirements that are often placed on Vishay Precision Group products. It is the customer s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or by any conduct of Vishay Precision products shown herein are not designed for use in life-saving or life-sustaining applications unless otherwise expressly indicated.

6 Customers using or selling Vishay Precision Group products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay Precision Group for any damages arising or resulting from such use or sale. Please contact authorized Vishay Precision Group personnel to obtain written terms and conditions regarding products designed for such names and markings noted herein may be trademarks of their respective technical questions, of ContentsTable of ContentsRevision: 18-May-2010 Instrument Selection.

7 2 Strain Indicators and CalibratorsP3 .. 6D4 .. 91550A .. 11 Model V/E-40 .. 13 Signal Conditioning AmplifiersA2 .. 162100 System .. 202200 System .. 242300 System .. 28 Digital Data SystemsSoftware for Stress Analysis Testing .. 34 System 5000 .. 37 System 6000 .. 41 System 7000 .. 50 Special-Purpose InstrumentsModel 1300 .. 58 Model 700 .. 60RS-200 .. 62 For technical questions, contact The A2, 2100, 2200, and 2300 Systems accept low-level signals, and condition and amplify them into high-level outputs suitable for multiple channel, simultaneous, dynamic recording.

8 All of these systems can be used in conjunction with a variety of recording devices. DIGITAL DATA SYSTEMSD epending on their design, digital data systems can be used for measurement of static, dynamic, or both kinds of signals. Micro-Measurements offers three digital data systems, each controlled with StrainSmart software and other third-party 5000 is a complete test and measurement data system for stress analysis and structural materials testing. Each 5100B scanner provides fast static data acquisition and digitization of 20 channels of various inputs.

9 System flexibility allows for mixing types of input cards within a scanner for various input types including Strain gages, thermocouples, LVDTs, load cells, and other transducer high level inputs. The system can be built up to 1200 channels, utilizing 60 scanners. Scan rates of up to 100 samples per second are available for simultaneous reading of all sensor 6000 is used for dynamic signals with scanning rates up to 10,000 samples per second per channel and up to 1200 channels. System 6000 provides individual analog-to-digital conversion on each channel and simultaneous sampling data acquisition for all channels.

10 Selectable, digital Finite Impulse Response (FIR) low-pass filtering is incorporated into each Instrumentation channel to meet a variety of testing requirements. Custom filters are also 7000 is a high performance dynamic data acquisition instrument with measurement accuracy of of full scale. Each sensor card employs a 24-bit analog to digital converter enabling microstrain resolution. Scan rates up to 2048 samples per second are available for simultaneous reading of all sensor inputs. A combination of analog and flexible Finite Impulse Response (FIR) filters are available to provide adequate anti-alias filtering at all scanning rates.


Related search queries