Atmel -46002B-SE- M90E26 -Datasheet_110714 FEATURESM etering Features Metering features fully in compliance with the requirements of IEC62052-11,IEC62053-21 and IEC62053-23; applicable in class 1 or class 2 single-phase watt-hour meter or class 2 single-phase var-hour meter. Accuracy of for active energy and for reactive energy over a dynamicrange of 5000:1. Temperature coefficient is 15 ppm/ C (typical) for on-chip reference voltage Single-point calibration over a dynamic range of 5000:1 for active energy; no cali-bration needed for reactive energy.

Atmel-46002B-SE-M90E26-Datasheet_110714 FEATURES Metering Features • Metering features fully in compliance with the requirements of IEC62052-11, IEC62053-21 and IEC62053-23; applicable in class 1 or class 2 single-phase watt-

Tags:

  M90e26

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Atmel M90E26 - Microchip Technology

1 Atmel -46002B-SE- M90E26 -Datasheet_110714 FEATURESM etering Features Metering features fully in compliance with the requirements of IEC62052-11,IEC62053-21 and IEC62053-23; applicable in class 1 or class 2 single-phase watt-hour meter or class 2 single-phase var-hour meter. Accuracy of for active energy and for reactive energy over a dynamicrange of 5000:1. Temperature coefficient is 15 ppm/ C (typical) for on-chip reference voltage Single-point calibration over a dynamic range of 5000:1 for active energy; no cali-bration needed for reactive energy.

2 Energy Meter Constant doubling at low current to save verification time. Electrical parameters measurement: less than fiducial error for Vrms, Irms,mean active/ reactive/ apparent power, frequency, power factor and phase angle. Forward/ reverse active/ reactive energy with independent energy registers. Active/reactive energy can be output by pulse or read through energy registers to adapt todifferent applications. Programmable startup and no-load power threshold. Dedicated ADC and different gains for L line and N line current sampling sampled over shunt resistor or current transformer (CT); voltage sampledover resistor divider network or potential transformer (PT).

3 Programmable L line and N line metering modes: anti-tampering mode (largerpower), L line mode (fixed L line), L+N mode (applicable for single-phase three-wiresystem) and flexible mode (configure through register). Programmable L line and N line power difference threshold in anti-tampering mode. Other Features single power supply. Operating voltage range: ~ Metering accuracyguaranteed within ~ 5V compatible for digital input. Built-in hysteresis for power-on reset. Selectable UART interface and SPI interface (four-wire SPI interface or simplifiedthree-wire SPI interface with fixed 24 cycles for all registers operation).

4 Parameter diagnosis function and programmable interrupt output of the IRQ inter-rupt signal and the WarnOut signal. Programmable voltage sag detection and zero-crossing output. Channel input range-Voltage channel (when gain is '1'): 120 Vrms~ line current channel (when gain is '24'): 5 Vrms~ line current channel (when gain is '1'): 120 Vrms~600mVrms. Programmable L line current gain: 1, 4, 8, 16, 24; Programmable N line gain: 1, 2, 4. Support L line and N line offset compensation. CF1 and CF2 output active and reactive energy pulses respectively which can beused for calibration or energy accumulation.

5 Crystal oscillator frequency: MHz. Atmel M90E26 Single-Phase High-Performance Wide-SpanEnergy Metering ICDATASHEET2M90E26 [DATASHEET] Atmel -46002B-SE- M90E26 -Datash eet_110714 Green SSOP28 package. Operating temperature: -40 C ~ +85 M90E26 is used for active and reactive energy metering for single-phase two-wire (1P2W), single-phase three-wire(1P3W) or anti-tampering energy meters. With the measurement function, the M90E26 can also be used in power instru-ments which need to measure voltage, current, etc. DESCRIPTIONThe M90E26 is a high-performance wide-span energy metering chip.

6 The ADC and DSP Technology ensure the chip's long-term stability over variations in grid and ambient environmental conditions. BLOCK DIAGRAMF igure-1 M90E26 Block DiagramReference Voltage Power On ResetCrystal OscillatorSPI / UARTVrefI1PI1 NVPVNL Line Forward/Reverse Active/Reactive PowerL Line Apparent PowerL Line IrmsVrmsI2PI2 NMMD1 MMD0CS SCLKSDO/UTXSDI/URXOSCIOSCORESET ADC ADCHPF1 HPF0 DSP ModulePGAX1/X4/X8/X16/X24 ADCA ctive Energy Pulse OutputReactive Energy Pulse OutputCF1CF2 HPF1 HPF0 HPF1 HPF0N Line Forward/Reverse Active/Reactive PowerN Line Apparent PowerN Line IrmsPower

7 Factor/Angle/FrequencyWarnOut/IRQ/ZXZXIR QWarnOutNGain3M90E26 [DATASHEET] 1 Application .. 2 Description .. 2 Block 21 Pin Assignment .. 72 Pin Description .. 83 Functional Description .. Dynamic Metering Range .. Startup and No-Load Power .. Energy Registers .. N Line Metering and Anti-Tampering .. Metering Mode and L/N Line Current Sampling Gain Configuration .. Anti-Tampering Mode .. Measurement and Zero-Crossing .. Measurement .. Zero-Crossing .. Calibration .. Reset .. 144 Interface.

8 SPI Interface .. Four-Wire Mode .. Three-Wire Mode .. Timeout and Protection .. UART Interface .. Byte Level Timing .. Write Transaction .. Read transaction .. Checksum .. WarnOut Pin for Fatal Error Warning .. Low Cost Implementation in Isolation with MCU .. 205 Register .. Register List .. Status and Special Register .. Metering/ Measurement Calibration and Configuration .. Metering Calibration and Configuration Register .. Measurement Calibration Register .. Energy Register.

9 Measurement Register .. 44 Table of Contents4M90E26 [DATASHEET] Atmel -46002B-SE- M90E26 -Datash eet_1107146 Electrical Specification .. Electrical Specification .. SPI Interface Timing .. Power On Reset Timing .. Zero-Crossing Timing .. Voltage Sag Timing .. Pulse Output .. Absolute Maximum Rating .. 56 Ordering 57 Packaging 58 Revision History .. 595M90E26 [DATASHEET] Atmel -46002B-SE- M90E26 -Datash eet_110714 Table-1 Pin Description .. 8 Table-2 Active Energy Metering Error .. 10 Table-3 Reactive Energy Metering Error.

10 10 Table-4 Threshold Configuration for Startup and No-Load Power .. 10 Table-5 Energy Registers .. 11 Table-6 Metering Mode .. 12 Table-7 The Measurement Format .. 13 Table-8 Read / Write Result in Four-Wire Mode .. 17 Table-9 Read / Write Result in Three-Wire Mode .. 17 Table-10 Register List .. 21 Table-11 SPI Timing Specification .. 53 Table-12 Power On Reset Specification .. 54 Table-13 Zero-Crossing Specification .. 55 Table-14 Voltage Sag Specification.