Example: tourism industry

I2-4 Weather-Proof Immersion IW-C, ACCESSORY E R U T A ...

Series I2-2. General Purpose Immersion Temperature Sensor Locking Screw Cover, Multiple Conduit Holes 2-1/4. [ ] 2X [ MM]. 3/8 NPT CONDUIT KNOCKOUTS. 3/8 NPT. 4-1/16 L. [ ] [L = FOR 6 THERMOWELL. L = FOR 4 THERMOWELL]. 3X [ MM]. 1/2 NPT CONDUIT KNOCKOUTS. The Series I2-2 General Purpose Immersion Temperature Sensor is ideal for SPECIFICATIONS Operating Temperature: -32 to 240 F. monitoring hot and chilled water lines throughout a building or mechanical room. The Accuracy: ( to C). plastic housing is in the shape of a standard junction box with multiple knockouts for easy Platinum RTD: @ 32 F (0 C); Probe Diameter: 1/4 ( mm). conduit access. The locking cover prevents unauthorized occupants from tampering with Nickel RTD: F @ 32 F (0 C); Cable Length: 8.

T e m p e r a t u r e S e n s o r s T E M P E R A T U R E 306 DWYER INSTRUMENTS, INC. | www.dwyer-inst.com Series I2-2 General Purpose Immersion Temperature Sensor Locking Screw Cover, Multiple Conduit Holes SPECIFICATIONS Accuracy: Platinum RTD: ±0.6% @ 32°F (0°C);

Tags:

  Inst, Dwyer inst, Dwyer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of I2-4 Weather-Proof Immersion IW-C, ACCESSORY E R U T A ...

1 Series I2-2. General Purpose Immersion Temperature Sensor Locking Screw Cover, Multiple Conduit Holes 2-1/4. [ ] 2X [ MM]. 3/8 NPT CONDUIT KNOCKOUTS. 3/8 NPT. 4-1/16 L. [ ] [L = FOR 6 THERMOWELL. L = FOR 4 THERMOWELL]. 3X [ MM]. 1/2 NPT CONDUIT KNOCKOUTS. The Series I2-2 General Purpose Immersion Temperature Sensor is ideal for SPECIFICATIONS Operating Temperature: -32 to 240 F. monitoring hot and chilled water lines throughout a building or mechanical room. The Accuracy: ( to C). plastic housing is in the shape of a standard junction box with multiple knockouts for easy Platinum RTD: @ 32 F (0 C); Probe Diameter: 1/4 ( mm). conduit access. The locking cover prevents unauthorized occupants from tampering with Nickel RTD: F @ 32 F (0 C); Cable Length: 8.

2 The temperature sensor. The Sensor I2-2 can be ordered with a choice of 11 output options Balco RTD: @ 32 F (0 C); Probe Material: 304 SS. that allow it to communicate to any standard building control system. Thermistors: F from 32 to Mounting: 1/2 threaded connection to 158 F (0 to 70 C). fit Series IW2 thermowell. Note: A Series IW2 Thermowell must be used on pressurized air and water lines to prevent leakage around the probe. Model Sensor Type Insertion Length Model Sensor Type Insertion Length I2-21062 Pt 100 RTD 6 I2-21042 Pt 100 RTD 4 . I2-22062 PT 1000 RTD 6 I2-22042 PT 1000 RTD 4 . I2-23062 Ni 1000 RTD 6 I2-23042 Ni 1000 RTD 4 . I2-24062 Balco 1000 RTD 6 I2-24042 Balco 1000 RTD 4.

3 I2-25062 10K Type 2 Thermistor 6 I2-25042 10K Type 2 Thermistor 4 . I2-26062 3K Thermistor 6 I2-26042 3K Thermistor 4 . I2-27062 5K Thermistor 6 I2-27042 5K Thermistor 4 . I2-28062 100K Thermistor 6 I2-28042 100K Thermistor 4 . I2-29062 20K Thermistor 6 I2-29042 20K Thermistor 4 . I2-2A062 2252 Thermistor 6 I2-2A042 2252 Thermistor 4 . I2-2B062 10K Type 3 Thermistor 6 I2-2B042 10K Type 3 Thermistor 4 . Thermowells ACCESSORY . Model Material Insertion Length IW-C, Thermowell Compound IW2-262 304 SS 6 . IW2-242 304 SS 4 . Series I2-4. Weather-Proof Immersion TEMPERATURE. Temperature Sensor Twist Off Cover, Multiple Conduit Holes 2-7/32 4X [ MM]. 3-31/32 [ ] 1/2 NPT CONDUIT KNOCKOUTS.

4 [ ] FOR 1/2 NPT THERMOWELL CONNECTION. 3-3/32 [ ]. 1/4. L [ ]. L = FOR 6 THERMOWELL. Temperature Sensors L= FOR 4 THERMOWELL. The Series I2-4 Weather-Proof Immersion Temperature Sensor is ideal for SPECIFICATIONS Operating Temperature: -32 to 240 F. monitoring hot and chilled water lines feeding Air Handlers and Cooling Towers. The Accuracy: ( to C). plastic housing has a 1/4 turn twist off cover to reduce installation time. The multiple Platinum RTD: @ 32 F (0 C); Probe Diameter: 1/4 ( mm). knockouts allow for easy conduit access to any side of the housing. The Series I2-4 can be Nickel RTD: F @ 32 F (0 C); Cable Length: 8 . ordered with a choice of 11 output options that allow it to communicate to any standard Balco RTD: @ 32 F (0 C); Probe Material: 304 SS.

5 Building control system. Thermistors: F from 32 to Mounting: 1/2 threaded connection to 158 F (0 to 70 C). fit Series IW2 thermowell. Note: A Series IW2 Thermowell must be used on pressurized air and water lines to prevent leakage around the probe. Model Sensor Type Insertion Length Model Sensor Type Insertion Length I2-41062 Pt 100 RTD 6 I2-41042 Pt 100 RTD 4 . I2-42062 PT 1000 RTD 6 I2-42042 PT 1000 RTD 4 . I2-43062 Ni 1000 RTD 6 I2-43042 Ni 1000 RTD 4 . I2-44062 Balco 1000 RTD 6 I2-44042 Balco 1000 RTD 4 . I2-45062 10K Type II Thermistor 6 I2-45042 10K Type II Thermistor 4 . I2-46062 3K Thermistor 6 I2-46042 3K Thermistor 4 . I2-47062 5K Thermistor 6 I2-47042 5K Thermistor 4.

6 I2-48062 100K Thermistor 6 I2-48042 100K Thermistor 4 . I2-49062 20K Thermistor 6 I2-49042 20K Thermistor 4 . I2-4A062 2252 Thermistor 6 I2-4A042 2252 Thermistor 4 . I2-4B062 10K Type III Thermistor 6 I2-4B042 10K Type III Thermistor 4 . Thermowells Model Material Insertion Length IW2-262 304 SS 6 . IW2-242 304 SS 4 . 306 dwyer INSTRUMENTS, INC. |