Example: stock market

Model GPIO-16 General Purpose Input Output Frame

Model GPIO-16 General Purpose Input Output FrameUser Manualup to and including version Rev F1/2010 PROPRIETARY NOTICEThe product information and design disclosed herein were originated by and are the property of Bosch Security Systems, Inc. Bosch reserves all patent, proprietary design, manufacturing, reproduction, use and sales rights thereto, and to any article disclosed therein, except to the extent rights are expressly granted to NOTICEC opyright 2010 by Bosch Security Systems, Inc. All rights reserved. Reproduction, in whole or in part, without prior written permission from Bosch is NOTICESee the enclosed warranty card for further SUPPORTT echnical questions should be directed to:Customer Service DepartmentBosch Security Systems, Portland Avenue SouthBurnsville, MN 55337 USAT elephone: 877-8

GPIO-16 TO ADAM SYSTEM ... Input Output Frame. GPIO-16 inputs and outputs are generally assigned using AZedit (intercom system configuration software). For more information on AZedit, see the AZedit User Manual (9350-7532-000). ... GPIO-16s may also be …

Tags:

  Input, Output, Gpio, Input output, Gpio 16

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Model GPIO-16 General Purpose Input Output Frame

1 Model GPIO-16 General Purpose Input Output FrameUser Manualup to and including version Rev F1/2010 PROPRIETARY NOTICEThe product information and design disclosed herein were originated by and are the property of Bosch Security Systems, Inc. Bosch reserves all patent, proprietary design, manufacturing, reproduction, use and sales rights thereto, and to any article disclosed therein, except to the extent rights are expressly granted to NOTICEC opyright 2010 by Bosch Security Systems, Inc. All rights reserved. Reproduction, in whole or in part, without prior written permission from Bosch is NOTICESee the enclosed warranty card for further SUPPORTT echnical questions should be directed to:Customer Service DepartmentBosch Security Systems, Portland Avenue SouthBurnsville, MN 55337 USAT elephone: 877-863-4169 Fax: Questions EMEAB osch Security Systems Technical Support SHIPPING INSTRUCTIONSC ustomer Service DepartmentBosch Security Systems, Inc.

2 (Lincoln, NE)Telephone: 402-467-5321 Fax: 402-467-3279 Factory Service: 800-553-5992 Please include a note in the box which supplies the company name, address, phone number, a person to contact regarding the repair, the type and quantity of equipment, a description of the problem and the serial number(s).SHIPPING TO THE MANUFACTURERAll shipments of product should be made via UPS Ground, prepaid (you may request from Factory Service a different shipment method). Any shipment upgrades will be paid by the customer. The equipment should be shipped in the original packing carton.

3 If the original carton is not available, use any suitable container that is rigid and of adequate size. If a substitute container is used, the equipment should be wrapped in paper and surrounded with at least four (4) inches of excelsior or similar shock-absorbing material. All shipments must be sent to the following address and must include the Proof of Purchase for warranty repair. Upon completion of any repair the equipment will be returned via United Parcel Service or specified shipper, Service DepartmentBosch Security Systems, East Cornhusker , NE 68507 : ServiceThis package should include the following.

4 QTYDESCRIPTIONPART Assembly - gpio -169010-7842-0001 Warranty381103871AC Cord88001026681 User Manual93507842000250 Contact Cable Mounted Assembly with Screws5390860002 Kit Screw Retainer8800102481 THE LIGHTNING FLASH AND ARROWHEAD WITHIN THE TRIANGLE IS A WARNING SIGN ALERTING YOU OF DANGEROUS VOLTAGE INSIDE THE : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER-SERVICABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE EXCLAMATION POINT WITHIN THE TRIANGLE IS A WARNING SIGN ALERTING YOU OF IMPORTANT INSTRUCTIONS ACCOMPANYING THE PRODUCTSEE MARKING ON BOTTOM/BACK OF PRODUCTWARNING: APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE : THE MAIN POWER PLUG MUST REMAIN READILY OPERABLECAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, GROUNDING OF THE CENTER PIN OF THIS PLUG MUST BE.

5 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPRATUS TO RAIN OR : TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY ATTACHED TO THE FLOOR/WALL/RACK IN ACCORDANCE WITH THE INSTALLATION product is AC Safety Instructions1. Read these Keep these Heed all Follow all Do not use this apparatus near Clean only with dry Do not block any ventilation openings. Install in accordance with the manufacturer s Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce Do not defeat the safety Purpose of the polarized or grounding-type plug.

6 A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the use attachments/accessories specified by the only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

7 When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from this apparatus during lightning storms or when unused for long periods of all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been SAFETY INSTRUCTIONS ..3 DESCRIPTION AND SPECIFICATIONS.

8 4 Introduction ..4 Description ..4 Theory of Operation ..4 Reference View ..5 Specifications ..6 CONNECTIONS ..6 Default Addresses for the RVON Product Line ..7 INSTALLATION AND OPERATION .. 8 Installation ..8 MOUNTING ..8 Multi-drop Connections ..10 GPIO-16 TO ADAM SYSTEM ..10 GPIO-16 TO ADAM CS SYSTEM ..10 GPIO-16 Frame INTERCONNECTIONS ..11 GPIO-16 TO ZEUS SYSTEM ..11 GPIO-16 TO CRONUS SYSTEM ..11GP Output and Input Connections ..11 POWER CONNECTION ..11 Assigning the GPIO-16 Inputs and Outputs ..12 USING AZEDIT ..12 USING KEYPANEL (OUTPUTS ONLY).

9 12 Operation ..13 STATUS INDICATORS ..13 GPIO-16 Frame RESET ..13 GPIO-16 AND AZEDIT .. 14 Configuring the GPIO-16 using AZedit ..14 ASSIGN THE GPIO-16 DEVICE TO THE RELAY GROUP IN AZEDIT ..17 Upgrade the GPIO-16 Firmware ..18 Notes ..204 CHAPTER 1 Description and SpecificationsIntroductionThis manual describes the installation, programming, and operating procedures for the RTS Model GPIO-16 General Purpose Input Output Frame . GPIO-16 inputs and outputs are generally assigned using AZedit (intercom system configuration software). For more information on AZedit, see the AZedit User Manual (9350-7532-000).

10 GPIO-16 (with Ethernet support) Firmware Requirements:AZeditVersion or laterMCII-eVersion or laterPeriphII-e with DBXV ersion or laterCronus Version or laterNOTE:The GPIO-16 works with the standard Master Controller in serial mode only. While using the standard master controller, the GPIO-16 runs exactly like a GPIO-16 provides 16 GPI ( General Purpose Inputs) and 16 GPO ( General Purpose Outputs). The GPIs can be set up as remotely controlled keypanel keys to activate intercom ports, party lines, GPOs, etc. within the intercom system.